+GF+turbidity analyzer 0-200NTU in stock supply

NegotiableUpdate on 05/20
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

+GF+turbidity analysis instruments are available in stock from 0-200NTU, with a large supply of GF turbidity instruments, GF conductivity, GFPH water quality analysis instruments, GF rotary flow meters, GF electromagnetic flow meters, and professional suppliers providing selection and debugging services.

Product Details

+GF+turbidity analyzer 0-200NTU in stock supply

Product Introduction

The iTurb 4160 turbidity online analyzer combines digital turbidity sensors with intelligent technology

The turbidity online analyzer and waterway can be integrated into a complete machine. In turbidity analysis

On the analyzer, measurement data can be viewed and managed, and calibration and other operations can be performed. that

The system integrates online analysis of water quality turbidity, remote data transmission, and data storage

Integrated with calibration function, it provides data collection and analysis for water turbidity

Extremely convenient.

The turbidity sensor measurement tank is equipped with a defoaming design, which can make the water sample after defoaming

Enter the turbidity measurement tank again. This instrument requires fewer water samples and has strong real-time performance.

A fine water sample flows through the defoaming grid and enters the measuring tank, and is always maintained

The water sample is circulated, and the instrument collects the turbidity of the water sample when it passes through the circulation device,

It can also be connected to the central control room or upper computer through digital communication.

application

Water plant inlet and outlet

• End of pipe network water

• Secondary water supply

• Pool water and membrane process water treatment equipment (direct drinking water, tap water, sewage)

Spot model 300149732 0-200NTU system features

Technical specifications of iTurb 4160 turbidity meter 0-200 NTU

Parameter technical specifications

Measurement parameter turbidity

Measuring principle

90 ° scattered light method

The light source is a laser

Compliant with EPA 180.1 standard

technical parameters

Range turbidity: 0.2~200NTU

Detect 0.2NTU

Accuracy ± 5% or ± 0.5NTU, whichever is greater

Zero drift ± 0 5NTU

Display resolution turbidity: 0.1NTU

Continuous measurement interval

Shell&Display

Display screen 240 * 160 dot matrix LCD screen

Material: The header and cabinet are both made of PC plastic

Dimensions: Length: 400mm, Width: 230mm, Height: 600mm

Protection level IP65

Software features

Function password management function password: set 3700, calibrate 3900, historical data 1300, historical curve 1400

Historical data is available, with a storage interval of 5 minutes

Data Logger with data recording, capable of storing 1000 pieces of data

Language: Chinese/English

output

Serial port output 1 RS485, Modbus RTU protocol

Current output 2-channel 4-20mA output

Relay output: 3-channel relay normally open contact output, high time (timed discharge)

Load: 5A/250VAC or 5A/30VDC

Installation requirements

Installation location: Indoor wall mounted

Imported pipe diameter 6mm

Export pipe diameter 10mm

Power supply voltage 100-240VAC, 50/60Hz

Power<20W

The requirement for measuring water quality is<200 NTU

Inlet flow rate<250mL/min

Sample temperature 0~45 ° C

Environmental temperature: 0 ° C~50 ° C

Storage temperature -40 ° C~70 ° C

Humidity<95% (uncondensed)

+GF+turbidity analyzer 0-200NTU in stock supply

+GF+浊度分析仪表0-200NTU现货供应

Installation and Wiring

Installation requirements

Wiring Instructions

1) The installation location of the instrument should be chosen in a spacious, ventilated, and dry indoor environment;

2) The instrument should be placed and fixed at a position slightly above the drainage water level (preferably 300mm above ground level) to facilitate smooth drainage;

3) Adequate space should be left around the instrument for personnel operation to facilitate later maintenance and calibration;

4) The horizontal height of the drainage pipe of the instrument should be lower than the horizontal height of the outlet of the instrument, and the total length of the outlet pipe should not exceed 3 meters, and there should be no blockage at the end.

5) The inlet and outlet pipes of the instrument are equipped with quick connectors, and the inlet pipes have matching conversion joints. Users can choose other conversion joints according to the actual situation on site, but

The pipeline ultimately connected to the instrument inlet cannot be changed;

6) Incoming water pressure: ≤ 0.3 Mpa;

7) Flow requirement: ≤ 250 mL/min;

8) Anti interference prevention measures: Do not share the same power supply with electric motors, frequency converters, and other high-power equipment;

9) Water and electricity measurement: After the instrument is powered on, open the inlet valve and the water sample enters the circulation pool. After the water level in the circulation pool reaches a certain height, the water sample flows out from the drainage outlet.

Georg Fischer (GF) founded 1802, headquartered in Schaffhausen, Switzerland, and has a presence in Swiss securities

Listed on the SWX SwissExchange. As an operating industrial group, GF is committed to becoming a sustainable water asset

In the field of source and fluid solutions.

GF is a supplier to many enterprises such as Intel, AMD, Huahong Hongli, Langshi, Contemporary, Vanke, etc., and has participated in the Beijing "Bird" project

"Nest", Expo Axis, Shanghai center Building, a large luxury cruise ship "Ida Mordor", the national ultra-high voltage

Many key projects such as demonstration projects for direct current transmission

Ordering Guide - Products

Manufacturer Part Number Order Code Description

ITurb 4160-1 300 149 731 Turbidity Meter 0.02-20NTU, Power Supply 100-240VAC, 50/60Hz

ITurb 4160-2 300 149 732 Turbidity Meter 0.2-200NTU, Power Supply 100-240VAC, 50/60Hz

ITurb 4160-3 300 149 733 turbidity meter 0.02-20 NTU seawater version, power supply 100-240VAC, 50/60Hz

ITurb 4160-4 300 149 734 turbidity meter 0.2-200 NTU seawater version, power supply 100-240VAC, 50/60Hz

ITurb 4160-5 300 149 774 turbidity meter 0.02-20NTU, power supply 24VDC

ITurb 4160-6 300 149 775 turbidity meter 0.2-200NTU, power supply 24VDC

ITurb 4160-7 300 149 735 turbidity meter 0.02-20 NTU seawater version, power supply 24VDC

ITurb 4160-8 300 149 736 turbidity meter 0.2-200 NTU seawater version, power supply 24VDC