- Phone
-
Address
Room 9011, Building B, Lane 519, Macau Road, Putuo District, Shanghai
Shanghai Xudun Electronic Technology Co., Ltd
Room 9011, Building B, Lane 519, Macau Road, Putuo District, Shanghai
+GF+turbidity analyzer 0-200NTU in stock supply
Product Introduction
The iTurb 4160 turbidity online analyzer combines digital turbidity sensors with intelligent technology
The turbidity online analyzer and waterway can be integrated into a complete machine. In turbidity analysis
On the analyzer, measurement data can be viewed and managed, and calibration and other operations can be performed. that
The system integrates online analysis of water quality turbidity, remote data transmission, and data storage
Integrated with calibration function, it provides data collection and analysis for water turbidity
Extremely convenient.
The turbidity sensor measurement tank is equipped with a defoaming design, which can make the water sample after defoaming
Enter the turbidity measurement tank again. This instrument requires fewer water samples and has strong real-time performance.
A fine water sample flows through the defoaming grid and enters the measuring tank, and is always maintained
The water sample is circulated, and the instrument collects the turbidity of the water sample when it passes through the circulation device,
It can also be connected to the central control room or upper computer through digital communication.
application
Water plant inlet and outlet
• End of pipe network water
• Secondary water supply
• Pool water and membrane process water treatment equipment (direct drinking water, tap water, sewage)
Spot model 300149732 0-200NTU system features
Technical specifications of iTurb 4160 turbidity meter 0-200 NTU
Parameter technical specifications
Measurement parameter turbidity
Measuring principle
90 ° scattered light method
The light source is a laser
Compliant with EPA 180.1 standard
technical parameters
Range turbidity: 0.2~200NTU
Detect 0.2NTU
Accuracy ± 5% or ± 0.5NTU, whichever is greater
Zero drift ± 0 5NTU
Display resolution turbidity: 0.1NTU
Continuous measurement interval
Shell&Display
Display screen 240 * 160 dot matrix LCD screen
Material: The header and cabinet are both made of PC plastic
Dimensions: Length: 400mm, Width: 230mm, Height: 600mm
Protection level IP65
Software features
Function password management function password: set 3700, calibrate 3900, historical data 1300, historical curve 1400
Historical data is available, with a storage interval of 5 minutes
Data Logger with data recording, capable of storing 1000 pieces of data
Language: Chinese/English
output
Serial port output 1 RS485, Modbus RTU protocol
Current output 2-channel 4-20mA output
Relay output: 3-channel relay normally open contact output, high time (timed discharge)
Load: 5A/250VAC or 5A/30VDC
Installation requirements
Installation location: Indoor wall mounted
Imported pipe diameter 6mm
Export pipe diameter 10mm
Power supply voltage 100-240VAC, 50/60Hz
Power<20W
The requirement for measuring water quality is<200 NTU
Inlet flow rate<250mL/min
Sample temperature 0~45 ° C
Environmental temperature: 0 ° C~50 ° C
Storage temperature -40 ° C~70 ° C
Humidity<95% (uncondensed)
+GF+turbidity analyzer 0-200NTU in stock supply

Installation and Wiring
Installation requirements
Wiring Instructions
1) The installation location of the instrument should be chosen in a spacious, ventilated, and dry indoor environment;
2) The instrument should be placed and fixed at a position slightly above the drainage water level (preferably 300mm above ground level) to facilitate smooth drainage;
3) Adequate space should be left around the instrument for personnel operation to facilitate later maintenance and calibration;
4) The horizontal height of the drainage pipe of the instrument should be lower than the horizontal height of the outlet of the instrument, and the total length of the outlet pipe should not exceed 3 meters, and there should be no blockage at the end.
5) The inlet and outlet pipes of the instrument are equipped with quick connectors, and the inlet pipes have matching conversion joints. Users can choose other conversion joints according to the actual situation on site, but
The pipeline ultimately connected to the instrument inlet cannot be changed;
6) Incoming water pressure: ≤ 0.3 Mpa;
7) Flow requirement: ≤ 250 mL/min;
8) Anti interference prevention measures: Do not share the same power supply with electric motors, frequency converters, and other high-power equipment;
9) Water and electricity measurement: After the instrument is powered on, open the inlet valve and the water sample enters the circulation pool. After the water level in the circulation pool reaches a certain height, the water sample flows out from the drainage outlet.
Georg Fischer (GF) founded 1802, headquartered in Schaffhausen, Switzerland, and has a presence in Swiss securities
Listed on the SWX SwissExchange. As an operating industrial group, GF is committed to becoming a sustainable water asset
In the field of source and fluid solutions.
GF is a supplier to many enterprises such as Intel, AMD, Huahong Hongli, Langshi, Contemporary, Vanke, etc., and has participated in the Beijing "Bird" project
"Nest", Expo Axis, Shanghai center Building, a large luxury cruise ship "Ida Mordor", the national ultra-high voltage
Many key projects such as demonstration projects for direct current transmission
Ordering Guide - Products
Manufacturer Part Number Order Code Description
ITurb 4160-1 300 149 731 Turbidity Meter 0.02-20NTU, Power Supply 100-240VAC, 50/60Hz
ITurb 4160-2 300 149 732 Turbidity Meter 0.2-200NTU, Power Supply 100-240VAC, 50/60Hz
ITurb 4160-3 300 149 733 turbidity meter 0.02-20 NTU seawater version, power supply 100-240VAC, 50/60Hz
ITurb 4160-4 300 149 734 turbidity meter 0.2-200 NTU seawater version, power supply 100-240VAC, 50/60Hz
ITurb 4160-5 300 149 774 turbidity meter 0.02-20NTU, power supply 24VDC
ITurb 4160-6 300 149 775 turbidity meter 0.2-200NTU, power supply 24VDC
ITurb 4160-7 300 149 735 turbidity meter 0.02-20 NTU seawater version, power supply 24VDC
ITurb 4160-8 300 149 736 turbidity meter 0.2-200 NTU seawater version, power supply 24VDC