(Colorimetric) Cell Adhesion Detection Kit

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Precautions for using the Cell Adhesion Detection Kit (Colorimetric): 1. The reagents in the spiral cap micro reagent tube should be centrifuged briefly before opening the lid to collect the liquid on the inner wall of the lid to the bottom of the tube, in order to avoid insufficient reagent volume due to liquid loss when opening the lid. 2. Cell processing requires careful handling to avoid human damage to cells as much as possible. Centrifugal force should be minimized as much as possible without losing cells, and the action of resuspending cells should be gentle to avoid repeated intense blows. No need for vortex oscillator.

Product Details

storage temperature
2-8 ℃, avoid light
Precautions
The validity period is the period during which the reagent kit is stored under the required conditions before being opened.
2.Cell adhesion detection kit (colorimetric)Please use it as soon as possible after opening!
Validity period
a year
detection method
Microplate Reader
Applicable samples
Animal adherent cells
Product Features
1. Convenience: Can be detected using an enzyme-linked immunosorbent assay (ELISA) reader;
2. Quick: The experiment can be completed within 1 hour;
3. Sensitivity: Reliable data, good reproducibility, wider linear range;

4. Accuracy: The reagent itself has high stability, and the experimental results are stable and reliable.

Product Application
Microplate Reader
Instrument preparation
1. ELISA reader
2. Centrifuge
3. Pipette
4. Refrigerator
5. Ice box
Reagent preparation
1. PBS buffer 2. HBSS
Preparation of consumables
1. Centrifugal tube
2. Suction head
3. Disposable gloves
Cell adhesion detection kit (colorimetric)Precautions for use
1. Before opening the screw cap micro reagent tube, please briefly centrifuge the reagent to collect the liquid on the inner wall of the cap to the bottom of the tube, in order to avoid insufficient reagent volume due to liquid loss when opening the cap.
2. Cell processing requires careful handling to avoid human damage to cells as much as possible. Centrifugal force should be minimized as much as possible without losing cells, and the action of resuspending cells should be gentle to avoid repeated intense blows. No need for vortex oscillator.