- Phone
-
Address
No. 616 Gudun Road, Xihu District, Hangzhou City
Hangzhou Qiannuo Biotechnology Co., Ltd
No. 616 Gudun Road, Xihu District, Hangzhou City
Abend 5702 centrifuge distributor in stock
Low speed centrifuges are one of the frequently used equipment in clinical testing, cell culture, and basic biochemistry laboratories. The Abend 5702 centrifuge, as the ambient temperature base model of the Eppendorf5702 series, provides efficient separation support for low to medium flux conventional tasks with a maximum speed of 4400rpm, a maximum capacity of 4 × 100mL, and a compact size design. This series covers three models: 5702 (normal temperature type), 5702R (freezing type), and 5702RH (cooling/heating type), which are respectively suitable for active temperature control scenarios such as standard room temperature separation, thermosensitive sample processing, and cell culture within the same capacity range. The overall design focuses on compact adaptation and low-noise operation of laboratory workbenches, while meeting low-speed daily centrifugation requirements, while also taking into account durable stainless steel rotor chambers and basic safety functions.
Choosing the Abend 5702 centrifuge means choosing a standardized room temperature equipment that fits the workspace, runs smoothly, and can withstand long-term use for your laboratory's routine low-speed centrifugation tasks.
1、 The core positioning differences among the three models
The 5702 series is based on the same core architecture of speed and capacity, forming a stepped configuration in temperature management function. Users can flexibly choose according to sample types and environmental requirements.
The 5702 room temperature model is the basic model of this series, which adopts an optimized airflow guidance design to minimize the sample heating rate during operation. It is suitable for routine experiments such as serum separation and cell precipitation that do not require a low-temperature environment. The 5702R freezing type integrates a refrigeration system on the basis of the normal temperature type, with a temperature control range covering -9 ℃ to 40 ℃. It has FastTemp rapid pre cooling function and ECO automatic standby energy-saving mode, and is suitable for centrifugal processing of heat sensitive samples such as RNA extraction and enzyme reactions. The 5702RH temperature control type further adds active heating function on the basis of the freezing type, which can maintain the set temperature accuracy throughout the centrifugation process, especially suitable for centrifuging live cells or cell cultures at around 37 ℃, helping to maintain cell viability and the reliability of downstream experimental results. The three models maintain consistency in core parameters such as maximum capacity (4 × 100mL), maximum speed (4400rpm), and maximum centrifugal force (3000 × g). The rotors can also be used interchangeably, and users do not need to reconfigure the rotor system to change the model.
Universal design advantages: compact, silent, convenient and safe daily guarantee
The Abend 5702 centrifuge series shares multiple design considerations in terms of operational safety and daily use. The stainless steel rotor cavity is sturdy, durable, and easy to clean, and can withstand conventional chemical reagents and sample residues. When the top cover is almost closed, the automatic lid lock function can prevent accidental opening and ensure operational stability. The imbalance detection system can automatically identify and intervene when there is a slight deviation in sample balancing, protecting the internal components of the centrifuge from damage. The "AtsetRPM" constant speed timing function can start timing only after reaching the preset speed, ensuring consistent centrifugal operating conditions for different batches and improving the comparability of data between experiments. The button lock function prevents accidental parameter changes, making it particularly suitable for laboratory multi-user sharing scenarios or strict execution of standard operating procedures. All parameters can be clearly displayed on the LCD screen, and users can quickly adjust the speed, time, and acceleration/deceleration mode through knobs and buttons.
At the level of human-computer interaction, the low opening height of the 5702 series (53cm for room temperature models and 60cm for freezing/temperature control models) makes it convenient for operators to load or remove samples from culture bottles or centrifuge racks with one hand in a low clearance environment. The acceleration and deceleration times are both within 25 seconds (25 seconds for the A-4-38 horizontal rotor with SOFT soft brake function at room temperature), providing a smooth start and stop curve, suitable for cell gradient separation and resuspension of fragile samples after centrifugation.
6 rotor systems: covering almost all types of centrifuge tubes
The Abend 5702 centrifuge series offers 6 rotor options, which can be adapted to almost all commonly used centrifuge tube types. Its maximum capacity is 4 × 100mL, which is a high space utilization rate under its compact appearance. The A-4-38 horizontal rotor can be paired with a 4 × 85mL circular basket, a 15mL/50mL Falcon tube adapter (2 sets, 2 per set), and a 13mm/16mm adapter for blood collection tubes. It can also accommodate 15mL/50mL conical centrifuge tubes and 5/7mL blood collection tubes, and can process 8 50mL samples or 36 13mm/30 16mm blood collection tubes simultaneously. The 24 13mm blood collection tubes or 4 100mL volumetric flasks corresponding to the 5702 horizontal rotor also meet the requirements of multi tube batch centrifugation. The A-4-81 horizontal rotor can hold 12 × 10/15mL or 6 × 50mL samples, suitable for batch exchange of cell culture media or collection of serum-free cultures. The A-8-17 horizontal rotor provides a standard capacity of 8 × 15mL. A-6-38 fixed angle rotor is suitable for 6 × 85mL, suitable for clarifying large capacity fermentation broth and bacterial precipitation. The breadth of tube wall compatibility allows the 5702 series to handle almost all types of tubes commonly found in clinical or cell culture laboratories.
2、 Overview of Core Technical Parameters
The following is a summary of the main technical parameters of each model of the Abend 5702 centrifuge for selection reference.
Technical specifications 5702 (normal temperature type) 5702R (frozen type) 5702RH (temperature controlled type)
Maximum speed 4400rpm 4400rpm 4400rpm 4400rpm
Maximum centrifugal force (RCF) 3000 × g3000 × g3000 × g
Maximum capacity 4 × 100mL4 × 100mL4 × 100mL
Temperature control range -9 ℃ to 40 ℃ -9 ℃ to 42 ℃
Acceleration time ≤ 19s or 25s ≤ 20s ≤ 19s
Deceleration time ≤ 19s or 25s ≤ 28s ≤ 29s
Timing range 0-99min, can centrifuge continuously 0-99min, can centrifuge continuously 0-99min, can centrifuge continuously 0-99min, can centrifuge continuously
Noise (A-4-38 rotor)<52dB (A)<46dB (A)<46dB (A)
Maximum power 200W380W380W
External dimensions (W x D x H) 32cm x 40cm x 24cm x 38cm x 58cm x 26cm x 38cm x 58cm x 26cm
Opening height 53cm 60cm 60cm
Weight (excluding accessories) 20kg 36kg 36kg 36kg
Temperature control function FastTemp rapid pre cooling; ECO automatic standby FastTemp quick pre cooling; ECO automatic standby; Active heating
The acceleration/deceleration time varies due to differences in rotor, load, and voltage versions; Source: Eppendorf product page and multiple domestic e-commerce product parameters.
3、 Selection Decision Framework
Application scenario recommendation model core considerations
The conventional serum separation and cell precipitation 5702 room temperature type does not require low temperature, has high cost-effectiveness, and has strong spatial adaptability on the table.
RNA extraction, enzyme reaction, protein purification, 5702R freezing type, wide temperature control range from -9 ℃ to 40 ℃; FastTemp can quickly pre cool the chamber to prevent sample deactivation.
Live cell culture and temperature sensitive samples (such as enzyme activity determination) can be maintained at 37 ℃ outside the cell culture box with 5702RH temperature controlled active heating, which improves cell viability and downstream experimental consistency.
summary
The Abend 5702 centrifuge, with its compact 32cm width (constant temperature type), stable output at 4400rpm, and six optional rotors for covering common tube types, is suitable for daily operation of routine tasks in low to medium flux scenarios. The room temperature type, with optimized airflow organization and low opening height design, is directly adapted to the sample pretreatment process in clinical examinations, cell culture, and biochemical centrifugation; The frozen and temperature controlled models expand their support for thermosensitive samples and live cell culture within the same capacity architecture, meeting differentiated temperature control requirements through temperature control capabilities ranging from -9 ℃ to 42 ℃. Based on the sensitivity of laboratory samples, budget conditions, and daily centrifugation flux, select the appropriate 5702 series model, and follow the standard horizontal basket adaptation and periodic calibration maintenance. This equipment will provide stable and reliable performance support for various low-speed centrifugation preparation processes.
Abend 5702 centrifuge distributor in stockHangzhou Qiannuo Biological Warehouse offers nationwide direct delivery of spot goods.