Maintenance and upkeep of biochemical incubators and light incubators
Date: 2015-10-22Read: 24

Maintenance and upkeep of biochemical incubators and light incubators: 1. Maintenance and upkeep of digital biochemical incubators: 1. Daily observation of incubator temperature to ensure compliance with regulations. If any abnormal situation is found, please seek professional repair in a timely manner. 2. When the lighting inside the box is abnormal, the lighting fixtures should be replaced in a timely manner. 3. When abnormal heating (cooling) is found, check whether the heating furnace wire is damaged and repair it in a timely manner. 4. Timely clean the outside of the incubator to maintain cleanliness and dust-free. Clean the inner chamber of the incubator with disinfectant once a week. Replace different types of disinfectant every quarter to avoid the production of drug-resistant bacteria. 5. This device should undergo a one-time performance verification every year. 2、 Maintenance and upkeep of digital illuminated incubators: 1. The incubator casing should be reliably grounded. 2. The incubator should be placed in a cool, dry, well ventilated place away from heat sources and direct sunlight. Place it steadily to prevent vibration and noise. 3. To ensure effective heat dissipation of the condenser, the distance between the condenser and the wall should be greater than 100mm, there should be a 50mm gap on the side of the box, and there should be at least 300mm of space at the top of the box. 4. When handling, repairing, and maintaining the incubator, collision, shaking, and vibration should be avoided, and the maximum inclination should be less than 45 degrees. 5. The instrument suddenly doesn't work. Please check if the fuse tube is burnt out and check the power supply. 6. When cooling this incubator, it is not advisable to make the temperature difference between the incubator and the ambient temperature greater than 25 degrees. 3、 Maintenance of oscillation incubator: 1. During continuous operation, the instrument should be checked regularly every three months; Check the fuse, control components and fastening screws, and whether there are water droplets, dirt, etc. falling onto the motor and control components. 2. The bearings of the transmission part have been filled with an appropriate amount of lubricating grease before leaving the factory. During continuous operation of the instrument, lubricating grease should be added every six months, with a filling amount of about one-third of the bearing space. 3. The compressor should avoid continuous starting.