Today we will talk about some common faults and solutions of box type resistance furnaces
Date: 2025-06-03Read: 0
box-type resistance furnaceIt mainly consists of two parts: the furnace body and the control box. Box type resistance furnaces generally work under natural atmospheric conditions and are mostly operated by internal heating, using refractory materials and insulation materials as the lining. Used for heat treatment such as normalizing, annealing, quenching, and other heating purposes on workpieces.
The control panel is equipped with an intelligent temperature regulator, which controls the power switch, main heating work/stop button, voltage and current meters. This product uses reliable integrated circuits, has a good working environment, anti-interference, and a furnace shell temperature rise of ≤ 30 ℃, greatly improving the working environment. It is controlled by a microcomputer program, programmable curves, fully automatic heating/cooling, and can modify temperature control parameters and programs during operation. It is flexible, convenient, and easy to operate.
Insufficient heating temperature:
Resistance wire breakage/temperature control instrument malfunction - replace heating element or calibrate temperature controller
Difficulty closing furnace door: track deformation/aging of sealing ring - clean track debris or replace seals
Abnormal noise: Fan imbalance/motor failure - rebalance fan blades or repair motor
Temperature out of control: thermocouple damage/controller failure - check thermocouple connection or replace controller
Safety and Maintenance Standards:
Daily maintenance:
Clean the furnace ash every week (operate after cooling).
Check the insulation porcelain tube of the heating element every quarter and replace it immediately if it is damaged.
Safety ban:
Prohibit the handling of flammable and explosive materials.
Do not open the furnace when the environmental humidity is above 80% RH or on rainy days.
When the furnace temperature is ≥ 500 ℃, the exhaust system must be turned on.