Welcome Customer !

Membership

Help

Guangzhou Lvbaicao Scientific Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Article

Guangzhou Lvbaicao Scientific Instrument Co., Ltd

  • E-mail

    mk@lubex.com.cn

  • Phone

    18922417705

  • Address

    2203, the Pearl River International Building, No. 112, Yuehua Road, Yuexiu District, Guangzhou

Contact Now
Reduce costs by 50%! LB52960 anion chromatography column, compliant with GB5009.26-2025
Date: 2025-12-18Read: 0

In the fields of food safety, environmental water quality monitoring, etc., compliance and cost control of anion testing have always been the core demands of laboratories. Although traditional imported anion exchange chromatography columns (such as AS11-HC and Thermo 052960) have stable performance, their high prices have put cost pressure on many laboratories.

Guangzhou Green Hundred Herbs launchedLBC11 anion analysis column(Item number LB52960) has become a new choice in the industry due to its advantages of "performance benchmarking imports+50% cost reduction".


image.png


As a device equipped withQuaternary ammonium alkyl alcohol based polystyrene divinylbenzene porous packed chromatography column, LB52960 adopts a 4.0 × 250mm specification and PEEK column tube design, adapted to the hydroxide system, and can accurately separate 7 common anions such as F ⁻, Cl ⁻, NO ₂⁻, PO ₄³ ⁻, as well as substances such as pyrophosphate and tripolyphosphate.

Its separation effect is excellent, and it can still achieve baseline separation of phosphate substances at a low concentration of 0.3mg/L. The response value is stable and reliable, which is consistent withMultiple national standard testing requirements such as GB 5009.26-2025 and HJ 84-2016Performance andAS11-HCTheThermo 052960Height benchmarking.


LBC11 Anion Analysis Column for Detection of Multiple Phosphates - Separation Efficiency Spectrum

At a concentration of 0.3 mg/L, phosphate ions (PO ₄³ ⁻), pyrophosphate, tripolyphosphate, and triphosphate all achieved ideal results with sharp peaks and baseline separation.


LUBEX LBC11 阴离子分析柱

Spectral diagram of LBC11 chromatographic column separation of four phosphates

image.png


Whether it is the control of excessive phosphate in food, the determination of inorganic anions in water quality, or ion detection in industrial process control, LB52960 can meet the needs with high adaptability. Without compromising on detection accuracy, the cost of laboratory consumables can be reduced by half. At the same time, when used in conjunction with the LBC11 dedicated protective column (item number LB52962), it can extend the service life of the chromatography column and further reduce comprehensive operation and maintenance costs.


For laboratories that pursue a balance between compliance and cost-effectiveness, LB52960 anion exchange chromatography column is undoubtedly the preferred alternative to AS11, AS11-HC, and Thermo 052960, helping laboratories to reduce costs and increase efficiency while maintaining the accuracy and compliance of detection data.