Welcome Customer !

Membership

Help

Deresheke (Langfang) Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Article

Deresheke (Langfang) Technology Co., Ltd

  • E-mail

    qianjuan@laserdl.cn

  • Phone

    13451510854

  • Address

    Building A1, Phase 1.1, Intelligent Manufacturing Industrial Park, Dachang Hui Autonomous County, Langfang City, Hebei Province

Contact Now
Chasing Light Classroom | The 'invisible stumbling block' of solar cells: how to solve the problem of metastability?
Date: 2025-10-11Read: 1

The efficiency of solar cells is a core concern in the industry, but crystalline silicon TOPCon、 Mainstream components such as perovskite cannot avoid an 'invisible trouble'——Metastable state phenomenon.The initial efficiency of illumination drops sharply, the IV test curve fluctuates between high and low, and the laboratory data and outdoor power generation performance frequently deviate, leaving many pitfalls for production testing and power generation evaluation.Today, we will dismantle this targeted solution and teach you how to deal with metastable interference, making battery performance calculations more accurate.






The core characteristics of metastable phenomena




图片


TOPCon component special mechanism:

  • Voltage index dependence: C_d ∝ exp (qV/kT)

  • Linear dependence of current: C_d ∝ I

  • Significantly near the maximum power point (Pmax), the value is much larger than the junction capacitance.





Key considerations for IV testing




01
Pre processing before testing (solving metastable interference)




  • Normalization of excited states:

  • The larger the reverse bias, the wider the depletion layer, and the smaller the capacitance value (C_j ∝ (V_bi - V) ^ {-1/2}).

  • Affects high-frequency response and limits the charging and discharging speed during light intensity transients.



02
Test process specification




02.png


03
Measures to address capacitance effect




  • Phenomenon:Transient IV curve caused by charging and discharging of metastable components

  • Solution:

  • Add before testing5-minute dark state rest(Release interface stored charge)

  • adoptComparison of Multi rate ScanningDiagnostic capacitance effect (0.1 V/s vs. 1 V/s)

  • introduceC-V testingQuantitative interface charge density (auxiliary correction IV result)






Association between outdoor power generation and laboratory data




03.png





Special optimization suggestions for TOPCon components




01
Low cost stimulation plan for production line:




Pulse light source preprocessing(1 solar intensity x 3 minutes, with intervals of 1 minute x 3 times)


02
Test automation upgrade:




  • Embedded adaptive algorithm:Real time monitoring of IV curve drift, dynamically extending/shortening preprocessing time


  • Output correction report:Automatically annotate the "metastable compensation factor" (based on capacitance test data)


03
Reference management:




  • choiceLow metastable sensitivity batchAs a calibration benchmark


  • Use DLTS every month(Deep level transient spectrum)Verify the stability of the defect state of the reference component





Summary: Core Risk Control Path




04.png


  • Execution priority:

  • Develop enterprise level 'IV Test Preprocessing Specification'

  • Develop capacitance efficiency correlation correction algorithm

  • Establish TOPCon metastable sample library (covering LID)/LETIDcase


  • Attachment: Example of Test Record Representation

05.png

Through the above framework, it is possible to systematically avoid the interference of metastable states on IV testing, ensuring consistency between laboratory data and outdoor power generation performance.