How often is the formaldehyde detector calibrated
Date: 2025-08-25Read: 0
Air formaldehyde detectorSuitable for on-site rapid quantitative detection of indoor air formaldehyde by indoor air treatment companies, air purification product manufacturers, decoration companies, environmental testing government functional departments, households and individuals.
1. The dual detection method for formaldehyde meets the requirements of the new national standard (phenol reagent method, AHMT method)
2. Self built work curves can meet more needs
3. 5-inch color touch screen with clear display
4. 2.9-inch e-ink screen with customizable shutdown screen
5. Support Bluetooth wireless printer
6. Product quality inspection report with CMA calculation
Calibration cycle basis:
Household detector:
It is recommended to perform calibration every 3 months, and for high humidity/high pollution environments, it should be shortened to monthly calibration.
Preheat in a ventilated environment for 2 hours before use, and verify accuracy with standard gas every month.
Professional testing equipment:
CMA certified equipment requires monthly calibration, and the lifespan of electrochemical sensors is usually 2-3 years.
Semiconductor sensors are recommended for calibration every 2 years and mandatory replacement every 3 years.
Abnormal environment:
The detector needs to be calibrated immediately after being exposed to oil fumes/dust.
After a sudden change in temperature and humidity (such as during the rainy season), the data should be revalidated.
Data exception:
Calibration is required if the reading does not match the sensory experience (such as being tasteless but displaying excessive levels).
Calibration and re inspection must be carried out 7-15 days after the governance project.
Precautions for use:
Calibration specifications:
Preheat in a ventilated environment for 2 hours before first use to reset the value to zero.
It is recommended to calibrate with standard gas every month to avoid sensor drift.
Testing environment requirements:
After closing the doors and windows for 12 hours, check and set up one sampling point for areas below 50 square meters.
Avoid using in cooking, perfume spraying and other scenarios to prevent data distortion.