Welcome Customer !

Membership

Help

Chongqing Shangli Instrument Equipment Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Chongqing Shangli Instrument Equipment Co., Ltd

  • E-mail

  • Phone

  • Address

    2nd Floor, Building 39, Chongqing University of Science and Technology, No. 20 East Road, University City, Shapingba District, Chongqing

Contact Now

thermal shock chamber

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Shangli Instrument supplies cold and hot shock test chambers and provides localized after-sales service. The TX-THS series cold and hot temperature impact test chamber accurately simulates the ambient temperature. The impact chamber structure consists of three boxes: a high temperature zone, a low temperature zone, and a sample zone. The sample zone is located in the middle of the high temperature zone and the low temperature zone, with an airflow valve between them. When the sample needs to undergo a high temperature test, the valve in the high temperature zone is opened and the valve in the low temperature zone is closed. When the sample undergoes a low temperature test, the valve in the low temperature zone is opened and the valve in the high temperature zone is closed, and the sample is in a stationary state. The rapid change in temperature is tested by the change in airflow.

Product Details

Shangli Instrument Supplythree-boxthermal shock chamberProvide localized after-sales service. The TX-THS series cold and hot temperature impact test chamber accurately simulates the ambient temperature. The impact chamber structure consists of three boxes: a high temperature zone, a low temperature zone, and a sample zone. The sample zone is located in the middle of the high temperature zone and the low temperature zone, with an airflow valve between them. When the sample needs to undergo a high temperature test, the valve in the high temperature zone is opened and the valve in the low temperature zone is closed. When the sample undergoes a low temperature test, the valve in the low temperature zone is opened and the valve in the high temperature zone is closed, and the sample is in a stationary state. The rapid change in temperature is tested by the change in airflow. The temperature in the high and low temperature zones, as well as the opening and closing coordination of valves, are set according to standards to achieve rapid switching of samples in high and low temperature environments, in order to verify the reliability of products under high and low temperature impacts. The high and low temperature impact test chamber is the fundamental instrument for controlling the reliability of weather resistance. This series of high and low temperature impact test chambers distinguishes models based on temperature control range and size. The temperature range of this series of test chambers can be selected from -55-200 ℃.

thermal shock chamberAlso known as the rapid temperature change test chamber, this test chamber is efficient, low-cost, and can quickly simulate environmental temperature. The temperature values of high and low temperature zones, as well as the opening and closing procedures of valves, can be freely set according to the requirements of the test standards. The TX-THS series cold and hot temperature shock test chamber can meet the standards of civilian or Jun products. Widely used in aerospace, military electronics, electronic and electrical components, circuit boards, communication products, display screens, paints and coatings, surface treatments, instruments and meters, automobiles, motorcycles and accessories, rubber and plastic products, metals, chemicals, building materials, aviation, military and other products that require attention to rapid temperature and humidity, for product reliability quality optimization and quality control.

This series of test chambers can meet the following standards (non-standard products will be customized separately):

GB/T10589-2008 Technical Conditions for Low Temperature Test Chamber, GB/T11158-2008 Technical Conditions for High Temperature Test Chamber, GB/T10592-2008 Technical Conditions for High and Low Temperature Test Chamber, GB/T2423.1-2008 Test A: Low Temperature, GB/T2423.2-2008 Test B: High Temperature, GB/T2423.22-2002 Test N: Temperature Change, GJB150.3A-2009 Part 3: High Temperature Test, GJB150.4A-2009 Part 4: High Temperature Test, GJB150.9A2009 Part 5: Temperature Impact Test, GJB150.9A2009 Part 18: Impact Test

Model (Tx THR) 27TF 125TF 300TF 27TS 125TS 300TS
Basket capacity (L) 27L 125L 300L 27L 125L 300L
studio dimensions 300x300x300 500x500x500 650x650x700 300x300x300 500x500x500 650x650x700
Outer box size (depth x width x height) mm 1600x1200x1900 2000x1700x2250 2100x1810x2520 1600x1200x1900 2000x1700x2250 2860x1550x2520
power supply AC380V (± 10%) 50HZ three box four wire+independent protective ground wire
performance parameters temperature Preheating temperature range +60℃-- +200℃
scope heating rate +60℃-- +200℃≤30min
Low temperature chamber Pre cooling temperature range -65℃-- -10℃ -70℃-- -10℃
降温速率 25℃-- -60℃≤70min 25℃-- -70℃≤60min
Experimental area temperature range -40℃-- +130℃ -55℃-- +150℃
Temperature response time ≤5min
Temperature conversion time ≤6s
Temperature recovery conditions +Exposure to 130 ℃ ≥ 30 minutes/-40 ℃ ≥ 30 minutes +Exposure to 150 ℃ for ≥ 30 minutes -55 ℃ for ≥ 30 minutes
Temperature uniformity ±2.0℃
temperature deviation ≤±2.0℃
material External material High quality cold-rolled steel plate, with surface rust prevention treatment and electrostatic spray coating
Inner box material SUS304 # mirror stainless steel
thermal insulation material Rigid polyurethane foam+glass fiber
controller monitor 7-inch, 800 * 480 dot matrix, true color LCD display
Setting method Chinese and English menus, touch screen input
Program capacity There are a total of 1000 sets of programs, with a maximum of 100 steps per set and a maximum of 999 loops per set. All 1000 sets of programs can be solidified, and each set of programs can be connected to each other, with a maximum of 10 sets connected
display resolution Temperature: 0.01 ℃ Time: 0.1min
temperature measurement *PT100 platinum resistor
communication function Equipped with Ethernet interface (broadband cable interface) as standard, it can achieve remote communication function of WEB SERVER, and can connect up to 200 devices at the same time
Recording function The sampling period can be freely selected from 1S to 60S. When the sampling period is 60S, it can store up to 600 days of historical data (24-hour operation)
refrigeration system refrigerator Imported refrigeration compressor
Cooling method Mechanical dual machine refrigeration
refrigerant R404a R23
cooling method Air cooled or water-cooled (according to customer requirements)
供水 Water supply method Pump motor water supply
water tower 10 cold tons, 15 cold tons, and 25 cold tons
Experimental water 生活用水
heater Fin heater
Electric heating film vacuum glass window (mm) 280x350
safety device Overtemperature protection; Leakage protection; Fan overload protection; Compressor overpressure, overload, overheating and overcurrent protection; Phase sequence protection; Fuse; Humidifier over temperature protection; Humidifier water shortage protection
Standard Configuration One test hole (50mm); 2 sample racks; 1 window light; Move 4; 1 USB interface
Optional accessories Paper or paperless recorder; Ink jet printer; Special specification test hole; Special specification sample rack; Water cooled cooling method; 10 inch touch screen LCD display; stainless steel casing