Siemens/Siemens 6GK6002-0AC09-0DA0switch
Media converter is a public utility level protocol free serial to fiber and serial standard converter that can meet all serial communication needs.
With the help of RMC20, RS485, RS422, or RS232 devices or networks can communicate over longer distances through secure, anti-interference, and optically isolated fiber optic wiring, and convert RS232 to RS485 or RS422 serial standards.
6GK6002-0AC01-0DA0
6GK6002-0AC02-0DA0
6GK6002-0AC03-0DA0
6GK6002-0AC04-0DA0
6GK6002-0AC05-0DA0
6GK6002-0AC06-0DA0
6GK6002-0AC07-0DA0
6GK6002-0AC08-0DA0
6GK6002-0AC09-0DA0
6GK6001-0AC08-0DA0
6GK6001-0AC07-0DA0
6GK6001-0AC06-0DA0
6GK6001-0AC05-0DA0
6GK6001-0AC04-0DA0
6GK6001-0AC03-0DA0
6GK6001-0AC02-0DA0
6GK6001-0AC09-0DA0
6GK6001-0AC01-0DA0
interface
Number of electrical connections
Used for network components and terminal devices/maximum value 1
Used for serial interface/according to RS 232/RS 422/RS 485/maximum value 2
Suitable for power supply 1
Suitable for redundant power supply 0
Electrical connection specifications
7-pin terminal board for network components and terminal devices
Suitable for power supply 3-pin terminal board
Number of optical connections
Used for network components and terminal devices/maximum value 1
Used for fiber optic/serial operations 1
Optical connection method/used for optical fibers
10 Mbit/s ST port (BFOC port)
scope
On the optical interface/depending on the fiber used/minimum value of 0 km
On the optical interface/depending on the fiber used/maximum value of 5 km
Supply voltage, current consumption, power loss
Product options/Wide Area Network components are
What is the fuse on the product component/power input terminal
Power loss [W]
Maximum value 3 W
environmental conditions
ambient temperature
During operation -40 .. +85 °C
Siemens/Siemens 6GK6002-0AC09-0DA0switch
Storage period -40 .. +85 °C
During transportation -40 .. +85 °C
The maximum operating temperature allowed by the remarks is+85 degrees Celsius, with a duration of 16 hours
Relative air humidity/at 25 ° C/no condensation/during operation/maximum 95%
Working conditions/fanless operation
Protection level IPIP30
Structural form, size, and weight
Compact structural form
Width 62.2 mm
Height 109 mm
Depth 92.8 mm
Net weight 0.68 kg
Product features/optional anti-corrosion coating
21 AWG electroplated steel shell for material/shell
Tightening type
35 mm DIN rail installation is
Is the S7-300 special-shaped guide rail installed