Welcome Customer !

Membership

Help

Beijing Zhongke Huaxing Science and Trade Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Beijing Zhongke Huaxing Science and Trade Co., Ltd

  • E-mail

  • Phone

  • Address

    Room A201, Fangyuan Building, No. 56 Zhongguancun South Street, Haidian District, Beijing

Contact Now

Rapid MAX N exceed large injection volume N element analyzer

NegotiableUpdate on 12/12
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Rapid MAX N exceed large injection volume N element analyzer

Product Details

elementar rapid MAX-N exceed.jpg

360截图1700101210212687.jpg

max1.jpgmax2.jpg

rapid MAX N exceed®

High performance protein analysis

Improve laboratory efficiency and significantly reduce the cost of individual sample testing. Rapid MAX N exceed is designed based on the Dumas method and utilizes the highly successful EAS REGAINER®A nitrogen/protein analyzer for technology that can also be used for larger sample weights. This instrument is designed for all-weather unmanned operation and is suitable for high-throughput laboratories with various sample types and weights.
Rapid MAX N excess represents excellent precision, sensitivity, and sample flexibility.

easy to use

Save valuable time during the sample preparation process. The unique combustion post-treatment technology ensures the complete digestion of challenging substances that are usually difficult to burn. Therefore, grinding or milling is usually omitted without affecting reliable data quality.

Maximum sample flux

Rapid MAX N exceed provides very fast nitrogen/protein determination within 5 minutes. Combined with a 90 bit automatic sampler, 300 samples can be measured daily. With proprietary EAS REGAINER®Technology can now run over 1000 samples without the need to exchange reducing agents. Therefore, customers can enjoy excellent low maintenance interventions and achieve industry-leading system uptime.

Sample flexibility

The vertical crucible design ensures that any liquid sample (such as milk, beer, soft drinks, juice, soy sauce, etc.) is fully burned. By combining unique combustion post-processing techniques, we achieve highly reliable data quality that is not affected by the substrate. The determination of 1 gram of solid sample achieves superior accuracy and precision.

Forward looking investment

Thanks to the excellent durability and lifespan of all element analyzers, both the combustion furnace and thermal conductivity detector (TCD) come with a ten-year warranty. As is well known, we have been committed to technical support for a long time, and the spare parts provided by Elementar can be used for at least 10 years. This results in a low total cost of ownership, giving customers confidence in receiving investment returns.

模式.jpg

Rapid MAX N exceed can be optimized for nitrogen/protein analysis.

Power Mode
For high sample weights, the strong mode can be used with a maximum adsorption capacity of 500 milligrams of carbon for the blowdown and capture chromatography column.

Quick Mode
To speed up the analysis time, the fast mode can be used, which has a maximum adsorption capacity of 100 milligrams of carbon for the blowdown and capture chromatography column.

规格.jpg

measurement method
High temperature combustion, 100% recovery and detection of released nitrogen. For nitrogen/protein, perform Dumas analysis according to AAOAC, DIN/ISO, EN, and relevant standards.

Easily handle samples
Weigh directly in a reusable crucible (steel or ceramic) without any special pre-treatment. Suitable for solids or liquids up to several grams or milliliters.

Safe, fast, and clean
Analysis only takes a few minutes. No corrosive or toxic chemicals are required. Separate water and interfering gases using physical and chemical methods.

Wide concentration range:
From 20 ppm to 100%, or 500 milligrams of absolute nitrogen content.

Low operational requirements
Less than 1 meter of experimental workspace, 1 power connector, and 2 types of operating gases are sufficient for free long-term operation. useHelium or argon gasThe operation of carrier gas is a standard procedure.

fully automatic
By integrating 90 sample changers and Windows based®Controlled operating software. Choose compatible software that meets the requirements of 21 CFR 11 regulations.

选项.jpg

Electronic balance:
The balance and elemental analyzer form a system. We provide analytical scales supplied by manufacturers for our instruments.

耗材.jpg

Our consumables kit includes all the components and chemicals required for effective use of the system. In most cases, it includes combustion tubes EAS REDUCTOR®All chemical and instrument specific vulnerable parts. We will not compromise on the quality of the components and chemicals we use - this is a prerequisite for ensuring the durability of our instruments.

Provide a consumable kit that can perform approximately 4000 analyses

Small vulnerable parts set:
A practical combination that includes the most important laboratory O-rings and fuses.

Of course, various consumables can also be ordered separately.

360截图1700101210212687.jpg