- Phone
-
Address
Room 201, Guanglou, Liantiao Mining Building, No. 1423 Renmin East Road, Gaobu Street, Yuecheng District, Shaoxing City, Zhejiang Province
Lichen Holdings (Hunan) Group Co., Ltd
Room 201, Guanglou, Liantiao Mining Building, No. 1423 Renmin East Road, Gaobu Street, Yuecheng District, Shaoxing City, Zhejiang Province

| instrument parameters | Parameter Details |
| Instrument model | LCA-PMD-2/4/6/8/10/12/16 |
| digit | 2/4/6/8/10/12/16 |
| power supply voltage | AV220V/50Hz |
| Total machine power | <2500W |
| temperature range | 0-250℃ |
| Temperature control method | PID frequency conversion technology |
| temperature control accuracy | 0.1℃ |
| Furnace cavity volume | 45L/50L/80L |
| Furnace cavity material | 316L stainless steel surface anti-corrosion treatment |
| Pressure measurement method | Sensor detection |
| Control pressure range | 0-6Mpa |
| Voltage control accuracy | 0.01Mpa |
| Microwave frequency | 2450MHz |
| Abnormal temperature alarm | have |
| Abnormal pressure alarm | have |
| Material of turntable frame | PP plastic |
| Dissolve the material of the inner tank | TFM (Tetrafluoroether) |
| Dissolve the volume of the inner tank | 100ml |
| Dissolve the material of the outer tank | PEEK(聚醚醚酮) |
| Net weight | 70kg |
| Overall dimensions | 540580760mm |
From the perspective of core measurement and control parameters, the temperature control accuracy of 0.1 ℃ and the pressure control accuracy of 0.01Mpa enable the equipment to achieve precise control of the digestion process, meeting the needs of various high-precision experiments; The temperature range of 0-250 ℃ and the pressure range of 0-6Mpa can cover the digestion conditions of most conventional and complex samples. In terms of the configuration of the digestion tank, the inner tank is made of TFM (tetrafluoroether) material, which has better corrosion resistance, high temperature resistance, and mechanical strength than ordinary polytetrafluoroethylene. Direct contact with the sample and strong acid reagents will not cause pollution, ensuring the accuracy of experimental data; The outer tank is made of PEEK (polyetheretherketone) material, which is a high-performance engineering plastic with compressive and impact resistance. PEEK provides strong protection for the inner tank, effectively preventing damage to the tank body caused by excessive pressure during the digestion process. The high-quality material combination of the inner and outer tanks creates a safe and pollution-free digestion environment.
At the same time, the entire series of equipment is equipped with dual temperature and pressure abnormal alarm functions. The sensor probing pressure measurement method makes pressure detection more direct and accurate, and can capture pressure changes in the digestion tank in real time, ensuring the safety and controllability of the digestion process from the details. The turntable frame made of PP plastic material balances portability and corrosion resistance, and can adapt to the working environment inside the furnace while effectively carrying the weight of the digestion tank.
4、 Product advantages and industry value
1. Domestic high cost-effectiveness, reducing laboratory procurement costs
The Lichen PMD series microwave digestion instrument is a pure domestic industrial grade equipment. Compared with similar imported products, it has a more advantageous price range while maintaining the same core performance and technical parameters. At the same time, the manufacturer's direct supply mode reduces intermediate links, further reducing laboratory procurement costs. In addition, the core components and vulnerable parts of the equipment are domestically matched, making maintenance and replacement of accessories more convenient and cost-effective in the later stage, significantly reducing the cost of equipment use and maintenance in laboratories, and enabling various types of laboratories in China to use high-performance industrial grade microwave digestion equipment.
2. Intelligent throughout the entire process, reducing operational barriers and improving experimental efficiency
From parameter setting, process monitoring to data export, the equipment has achieved intelligent operation throughout the entire process. The 10 inch 4K high-definition display screen and simple operation interface allow experimenters to quickly get started without professional microwave technology knowledge; Continuous non pulse microwave output, 360 degree unidirectional continuous rotation and other technologies enable sample digestion without manual intervention, achieving automated synchronous digestion; The high-power exhaust cooling system significantly shortens the cooling time after digestion. Compared with traditional electric heating plate digestion methods, the efficiency is improved several times or even tens of times, which can effectively improve the sample pretreatment efficiency in the laboratory and meet the needs of high-throughput detection.
3. Multiple security protection designs to eliminate experimental safety risks
The core safety pain point of microwave digestion lies in the risks of explosion and leakage in high temperature and high pressure environments. The Lichen PMD series microwave digestion instrument has built a safety protection system from multiple aspects such as structural design, system control, and component materials: six layer steel structure explosion-proof furnace door, double locking self inspection, temperature and pressure double abnormal alarm, PID intelligent temperature and pressure control, coupled with the pressure resistant and anti-corrosion combination of TFM inner tank and PEEK outer tank, eliminating safety risks from the source to the process, allowing experimental personnel to operate with confidence, and providing solid guarantee for the safe operation of the laboratory.
4. Accurate and traceable data to meet standardized laboratory management
The temperature control accuracy of 0.1 ℃ and the pressure control accuracy of 0.01Mpa make the parameter control of the digestion process more precise, ensuring sample digestion and good parallelism and repeatability of experimental data; The accompanying intelligent software can record all parameter changes during the digestion process in real time and support one click data export, achieving the recording, traceability, and analysis of experimental data, meeting the standardized requirements of modern laboratories in data management, experimental traceability, report issuance, and providing reliable data support for scientific research experiments and testing work.
5. Strong adaptability to multiple fields, one-stop solution for sample digestion problems
The industrial grade design and diverse model selection of the equipment enable it to meet the sample digestion needs of many industries such as healthcare, food/agricultural products, chemical, biotechnology, pharmaceuticals/biopharmaceuticals, etc. Whether it is heavy metal detection in food, pollutant analysis in environmental water samples, sample composition analysis in biomedicine, or purity detection of chemical raw materials, the Lichen PMD series microwave digestion instrument can set personalized digestion parameters based on sample characteristics, achieve rapid digestion, and solve the pre-treatment problems of different fields and types of samples in one stop.

5、 Equipment usage and maintenance instructions
Daily usage precautions
1. The equipment should be placed on a ventilated, dry, and flat experimental platform, away from water sources, fire sources, and strong magnetic fields. The power connection should meet the requirements of AV220V/50Hz and be equipped with grounding protection to prevent leakage accidents.
2. Before digestion, it is necessary to check the sealing and integrity of the digestion tank. If there are scratches or damages in the TFM inner tank, it should be replaced in a timely manner to avoid liquid leakage during the digestion process; The PEEK outer can needs to be kept clean and free from cracks, deformations, and other issues.
3. The amount of sample and digestion reagent added must be strictly controlled, not exceeding one-third of the volume of the digestion inner tank, to prevent safety accidents caused by excessive pressure during the digestion process.
During the operation of the equipment, experimenters are not allowed to open the furnace door at will. If an alarm signal appears, the equipment must be stopped immediately, the fault must be investigated and resolved before continuing to use.
After the digestion is completed, the furnace chamber and digestion tank need to be cooled to room temperature through a high-power exhaust cooling system before being removed to avoid high-temperature burns; Wear acid resistant gloves and goggles when removing the digestion tank to prevent strong acid reagents from coming into contact with the skin and eyes.
Daily maintenance and upkeep
1. After each use, it is necessary to clean the inside of the furnace chamber and the turntable frame in a timely manner. Use a clean damp cloth to wipe the inner wall of the furnace chamber. If there is residual strong acid reagent, use a small amount of deionized water to clean it and air dry it to keep the inside of the furnace chamber clean and prevent acid mist corrosion.
2. Regularly check the operating status of core components such as magnetron, exhaust system, sensors, etc. If there are abnormal noises, poor heat dissipation, inaccurate parameter detection, etc., it is necessary to contact the manufacturer for repair in a timely manner.
3. The digestion tank needs to be regularly maintained, and the TFM inner tank should be cleaned and dried in a timely manner after use to avoid prolonged residue of strong acid reagents; PEEK outer cans should avoid severe collisions to prevent deformation and damage.
When the equipment is not used for a long time, the power should be cut off, the equipment should be covered with a dust cover, and placed in a dry and ventilated environment to prevent moisture and dust accumulation.