flow transmitter
|

purpose
|
||||||
CS-3051DP type A flow transmitter is specifically designed to receive differential pressure signals from throttling elements, which are converted into 4-20mA.DC signals proportional to the flow rate through a "J" type electronic circuit board with square root function. This product uses electronic switch components to switch the relationship between the output current below 20% and the input differential pressure to linear, reducing the instability of the output current of the flow transmitter in the initial working section (especially at zero). However, when the output current is below 50%, due to the higher conversion sensitivity of the flow transmitter compared to differential pressure transmitters of the same specification, its stability is still slightly inferior to differential pressure transmitters.
|
||||||
General technical performance and parameters
|
||||||
|
||||||
|
Range ratio: 10:1 or 100:1 Power supply impact:<0.005% output range/V Load impact: When the power supply is stable, there is no load impact. Measurement accuracy: ± 0.1%, ± 0.2% of the calibration range (standard accuracy is ± 0.2%, if other accuracies are selected, please indicate them when ordering and selecting.) Damping: usually adjustable between 0.1 and 16 seconds. Start time:<2 seconds, no preheating required Working environment: ambient temperature -29~93 ℃ (analog amplifier) -29~75 ℃ (digital/smart amplifier) -29-65 ℃ (with display header) Environmental humidity: 0-95% Protection feature: IP65 protection capability Explosion proof type: Explosion proof Exd II BT4-6 Intrinsically safe Exia II CT5 Static pressure influence: Zero position error: ± 0.5% maximum range limit, calibrated by zeroing for 32MPa under pipeline pressure. Electromagnetic radiation impact: 0.05% maximum range value, accepted radiation frequency of 27-500MHz, test field strength of 3V/m. Indicator (%): LCD digital display accuracy ± 0.2% Vibration effect: ± 0.05%/g when vibrating at 200Hz in any direction. Installation position: The diaphragm is not installed vertically, which may result in a zero point error of less than 0.24KPa, but it can be corrected by adjusting the zero point. Weight: 3.9Kg (excluding accessories) |
||||||
CS-3051DP Type flow transmitter
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
CS-3051DP 3 J 2 2 C M3 B1 0~2.5KPa
|
||||||
| Note: For external dimensions, installation method, and pressure connection method, please refer to the pressure connection method of CS-3051DP differential pressure transmitter. | ||||||