Phone
18994599789
-
Address
Jiangsu Jinhu Industrial Park has been changed to No. 8 West Road
Long March Instrument (Jinhu) Co., Ltd
18994599789
Jiangsu Jinhu Industrial Park has been changed to No. 8 West Road
|
model
|
pressure of use
|
air consumption
|
Impact energy N.M
|
weight
|
|
CZ-30
|
0.3-0.7Mpa
|
0.05-0.13L/round
|
5.5-13.1
|
1.1kg
|
|
CZ-40
|
0.3-0.7Mpa
|
0.15-0.37L/round
|
9.2-22.2
|
2.7kg
|
|
CZ-60
|
0.3-0.7Mpa
|
0.33-0.77L/round
|
20.6-49.0
|
6.0kg
|
|
CZ-80
|
0.4-0.6Mpa
|
0.60-1.40L/round
|
45.1-109.0
|
12.5kg
|
Model size
|
model
|
A
|
φB
|
φC
|
D
|
φH
|
IN
|
OUT
|
|
CZ-30
|
135
|
82
|
67
|
14
|
9
|
1/4″PT
|
1/8″PT
|
|
CZ-40
|
175
|
98
|
77
|
18
|
11
|
1/4″PT
|
1/8″PT
|
|
CZ-60
|
220
|
143
|
110
|
17
|
12.5
|
1/4″PT
|
1/4″PT
|
|
CZ-80
|
275
|
170
|
140
|
25
|
17
|
3/8″PT
|
3/8″PT
|
|
abnormal situation
|
Possible reasons
|
Check and exclude
|
|
◆ Unable to start
|
◆ No air source or low pressure
|
Check if the pressure indication of the air conditioning combination is normal
|
|
The solenoid valve does not operate
|
◆ Disconnect the air pipe that catches the pneumatic hammer at the solenoid valve end, and check if there is any gas spraying by operating the solenoid valve
|
|
|
◆ Incorrect installation of intake and exhaust pipes
|
Check if the intake and exhaust pipes of the solenoid valve are installed properly
|
|
|
◆ Incorrect selection of solenoid valve
|
The pneumatic striking hammer must be selected as a three port two position or five port two position, otherwise it will not be able to exhaust after the action and will not work the next time.
|
|
|
The impact force is too small or cannot be started
|
One main pipe is equipped with too many branch pipes, and the size of the main pipe is the same as that of the branch pipes
|
The cross-sectional area of the main pipe should be the sum of the cross-sectional areas of the branch pipes, or separate piping should be set up to ensure that the pneumatic hammers do not affect each other
|
|
The gas source is insufficient for the pipe diameter, the three-point combination of the solenoid valve does not meet the specified requirements, or the piping is too long
|
Check whether the pipeline specifications and installation are correct, the pipeline length should be within 5 meters, and check whether the electromagnetic valve air conditioning combination specifications and installation are correct
|
|
|
The air pressure is too low
|
Check the air source and air conditioning combination, and increase the air pressure to the specified pressure
|
|
|
The diameter of the piping does not meet the requirements
|
Check if the pipeline specifications are correct
|
|
|
◆ Muffler blockage
|
Replace the muffler and adjust the fuel supply of the air conditioner
|
|
|
◆ Knocking noise
|
The screw fixing the pneumatic hammer is not tightened
|
◆ Re lock
|
|
|
Poor welding or insufficient strength with the fixed frame of the struck object. There are foreign objects or malfunctions inside the pneumatic striking hammer
|
◆ Recheck welding, remove pneumatic hammer, clean or maintain
|
|
◆ Electromagnetic valve noise
|
There are foreign objects or malfunctions inside the solenoid valve
|
◆ Clean or repair the solenoid valve
|