Output current of zirconia oxygen analyzer for ironmaking and sintering: 4-20mA. (The output signal corresponds to the display oxygen content of 0-5%, 0-10%, 0-20.6%, 0-25% O2 range, which can be selected.)

Product Details

Zirconia oxygen analyzer for ironmaking and sinteringFeatures:

● Anti smoke dust particle erosion

Can withstand flue gas pressures ranging from -10KPa to -20KPa

The detector filter has waterproof and anti-corrosion functions

The components of the terminal box are resistant to high temperatures


Zirconia oxygen analyzer for ironmaking and sinteringTechnical specifications:

Measuring element: oxygen sensor

Measurement range: 0-20.6% O2 (special requirements to be discussed separately)

● Output current: 4-20mA. (The output signal corresponds to the displayed oxygen levels of 0-5%, 0-10%, 0-20.6%, and 0-25%. The O2 range is optional.). )

The detector heating furnace heats up and takes about 20 minutes to reach the working temperature.

● Standard length of detector: 180mm, 600mm, 1000mm, 1200mm. Special requirements to be discussed separately.

● Repeatability ≤± 0.1% FS

● Basic error ≤ ± 2% FS

Stability ≤ ± 1% FS (instrument continuously calibrated for 24 hours)

Response time: When standard gas is introduced from the detector inlet, 90% response is achieved within 5 seconds.

● Environmental temperature: Detector -20 ℃~80 ℃ Converter -20 ℃~60 ℃

Power supply and power consumption: The power supply is 220 ± 10% VAC 50Hz, with a power consumption not exceeding 150W.


External dimensions:


  • Wall mounted converter



    Special detector for ironmaking and sintering