Welcome Customer !

Membership

Help

Beijing Shouyi Huaqiang Electronic Equipment Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Zirconia oxygen analyzer for hazardous waste incineration

NegotiableUpdate on 01/08
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The zirconia oxygen analyzer for hazardous waste incineration adopts the sampling adapter self guided flow and blowing anti-corrosion isolation technology, which avoids detector corrosion, easy blockage, and oxygen sensor electrode damage. The sampling adapter does not require drainage and uses the flow rate of flue gas as the driving force to generate self circulating flow guidance.

Product Details

Zirconia oxygen analyzer for hazardous waste incinerationFeatures:

The sampling adapter adopts self guided flow and blowing anti-corrosion isolation technology, which avoids detector corrosion, easy blockage, and oxygen sensor electrode damage. The sampling adapter does not require drainage and uses the flow rate of flue gas as the driving force to generate self circulating flow guidance.

● It has a timed blowing function, which intermittently blows the sampling adapter to ensure that the sample gas remains unobstructed.

The front end of the detector is equipped with a filter to block the influence of complex harmful components in the smoke on the oxygen sensor.

The electrode reinforcement and ion membrane coating protection of the oxygen sensor have extended the service life of the detector.


Zirconia oxygen analyzer for hazardous waste incinerationTechnical specifications:

Measuring element: oxygen sensor

Measurement range: 0-20.6% O2 (special requirements to be discussed separately)

Output current: 4-20mA (the output signal corresponds to the displayed oxygen levels of 0-5%, 0-10%, 0-20.6%, and 0-25%, with optional O2 ranges). )

The detector heating furnace heats up and takes about 20 minutes to reach the working temperature.

● Standard length of detector: 180mm

● Repeatability ≤± 0.1% FS

● Basic error ≤ ± 2% FS

Stability ≤ ± 1% FS (instrument continuously calibrated for 24 hours)

Response time: When standard gas is introduced from the detector inlet, 90% response is achieved within 5 seconds.

● Environmental temperature: Detector -20 ℃~80 ℃ Converter -20 ℃~60 ℃

Power supply and power consumption: The power supply is 220 ± 10% VAC 50Hz, with a power consumption not exceeding 150W.


External dimensions:

  • Blow control box

    Special sampling device for hazardous waste

    Instrument protection box

    Self guided flow pattern detector