Yuxi Siemens inverter agent

NegotiableUpdate on 05/16
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Yuxi Siemens frequency converter agents guarantee that all products purchased from our company are brand new, with a penalty of ten for each fake product. We can sign a formal sales contract. Our company mainly deals in S7-200, S7-300, S7-1200, S7-400 PLC modules, touch screens, communication cables, programming cables, DP connectors, LOGO, Model fast SMART modules, soft starters, servo motors, frequency converters, and other products are covered by Siemens' one-year warranty. Free replacement of new products within one year due to product quality issues; No fees charged

Product Details

Yuxi Siemens inverter agent

Hunan Bojunyi Intelligent Technology Co., Ltd. is a Siemens first level authorized agent

All products purchased from our company are guaranteed to be brand new, and formal sales contracts can be signed. Our company mainly operates S7-200, S7-300, S7-1200, S7-400 PLC modules, touch screens, communication cables, programming cables, DP connectors, LOGO, Model fast SMART modules, soft starters, servo motors, frequency converters, and other products are covered by Siemens' one-year warranty. Free for product quality issues within one year

Yuxi Siemens inverter agent

The product is sold in 23 provinces and 5 autonomous regionsMajor regions

Managing Siemens * spot goodsPLCS7-200S7-300 S7-400 S7-1200Touch screen, frequency converter,6FC6SNS120 V10 V60 V80Servo CNC spare parts: * motor(1LA7The1LG4The1LA9The1LE1)Domestic motor(1LG01LE0)Large motor(1LA81LA41PQ8)Servo motor(1PH1PM1FT1FK1FS)Siemens products are covered by a one-year warranty. Free replacement of new products within one year due to product quality issues; No charge

SIEMENS programmable controller

Where is it sold? How much does it cost? Where can I buy it? Where can I buy it? Where is the price, specifications, model, which is cheaper? Where is it available? Sales, order number, how much does it cost? Which one has the best price? Manufacturer, performance, advantages, packaging, purpose, after-sales service! Where can I find sales agents and general agents

Siemens frequency converter6SE6440-2UD42-0GB1Sales of Siemens MM440, MM430, and MM420 frequency convertersSales agent Siemens
Siemens Zhejiang agent

Siemens MM440 frequency converter

ICROMASTER 440 series (constant torque)

Siemens frequency converter Siemens frequency converter

6SE6400-1PB00-0AA0
6SE6400-1PC00-0AA0
6SE6400-1PC00-0AA0
6SE6420-2AB13-7AA1
6SE6420-2AB22-2BA1
6SE6440-2UC11-2AA1 0.12 KW
6SE6440-2UC11-2AA1 0.12 KW
6SE6440-2UC12-A1 0.25 KW
6SE6440-2UC13-7AA1 0.37 KW
6SE6440-2UC15-A1 0.55 KW
6SE6440-2UC17-A1 0.75 KW
6SE6440-2UC21-1BA1 1.1 KW
6SE6440-2UC21-5BA1 1.5 KW
6SE6440-2UC22-2BA1 2.2 KW
6SE6440-2UC23-0CA1 3 KW
6SE6440-2UC24-0CA1 4 KW
6SE6440-2UC25-5CA1 5.5 KW
6SE6440-2UC27-5DA1 7.5 KW
6SE6440-2UC31-1DA1 11 KW
6SE6440-2UC31-5DA1 15 KW
6SE6440-2UC31-8EA1 18.5 KW
6SE6440-2UC32-2EA1 22 KW
6SE6440-2UC33-0FA1 30 KW
6SE6440-2UC33-7FA1 37 KW
6SE6440-2UC34-5FA1 45 KW
380~480 3 ac Unfiltered without built-in filter
6SE6440-2UD13-7AA1 0.37 KW
6SE6440-2UD15-A1 0.55 KW
6SE6440-2UD17-A1 0.75 KW
6SE6440-2UD21-1AA1 1.1 KW
6SE6440-2UD21-A1 1.5 KW
6SE6440-2UD22-2BA1 2.2 KW
6SE6440-2UD23-0BA1 3 KW
6SE6440-2UD24-0BA1 4 KW
6SE6440-2UD25-5CA1 5.5 KW
6SE6440-2UD27-5CA1 7.5 KW
6SE6440-2UD31-1CA1 11 KW
6SE6440-2UD31-5DA1 15 KW
6SE6440-2UD31-5DB1 15 KW
6SE6440-2UD31-8DA1 18.5 KW
6SE6440-2UD31-8DB1 18.5 KW
6SE6440-2UD32-2DA1 22 KW
6SE6440-2UD32-2DB1 22 KW
6SE6440-2UD33-0EA1 30 KW
6SE6440-2UD33-0EB1 30 KW
6SE6440-2UD33-7EA1 37 KW
6SE6440-2UD33-7EB1 37 KW
6SE6440-2UD34-5FA1 45 KW
6SE6440-2UD34-5FB1 45 KW
6SE6440-2UD35-5FA1 55 KW
6SE6440-2UD35-5FB1 55 KW
6SE6440-2UD37-5FA1 75 KW
6SE6440-2UD37-5FB1 75 KW
6SE6440-2UD38-8FA1 90 KW
6SE6440-2UD38-8FB1 90 KW
6SE6440-2UD41-1FA1 110 KW
6SE6440-2UD41-1FB1 110 KW
6SE6440-2UD41-3GA1 132 KW
6SE6440-2UD41-3GB1 132 KW
6SE6440-2UD41-6GA1 160 KW
6SE6440-2UD41-6GB1 160 KW
6SE6440-2UD42-0GA1 200 KW
6SE6440-2UD42-0GB1 200 KW
500~600V 3 ac Unfiltered without built-in filter
6SE6440-2UE17-5CA1 0.75 KW
6SE6440-2UE21-5CA1 1.5 KW
6SE6440-2UE22-2CA1 2.2 KW
6SE6440-2UE24-0CA1 4 KW
6SE6440-2UE25-5CA1 5.5 KW
6SE6440-2UE27-5CA1 7.5 KW
6SE6440-2UE31-1CA1 11 KW
6SE6440-2UE31-5DA1 15 KW
6SE6440-2UE31-8DA1 18.5 KW
6SE6440-2UE32-2DA1 22 KW
6SE6440-2UE33-0EA1 30 KW
6SE6440-2UE33-7EA1 37 KW
6SE6440-2UE34-5FA1 45 KW
6SE6440-2UE35-5FA1 55 KW
6SE6440-2UE37-5FA1 75 KW
208~240 1 ac with filter with built-in filter
6SE6440-2AB1102AA1 0.12 KW
6SE6440-2AB12-A1 0.25 KW
6SE6440-2AB13-7AA1 0.37 KW
6SE6440-2AB15-A1 0.55 KW
6SE6440-2AB17-A1 0.75 KW
6SE6440-2AB21-1BA1 1.1 KW
6SE6440-2AB21-5BA1 1.5 KW
6SE6440-2AB22-2BA1 2.2 KW
6SE6440-2AB23-0CA1 3 KW
208~240 1/3 ac with filter with built-in filter
6SE6440-2AC23-0CA1 3 KW
6SE6440-2AC24-0CA1 4 KW
6SE6440-2AC25-5CA1 5.5 KW
380~480V 3 ac with filter with built-in filter
6SE6440-2AD22-2BA1 2.2 KW
6SE6440-2AD23-0BA1 3 KW
6SE6440-2AD24-0BA1 4 KW
6SE6440-2AD25-5CA1 5.5 KW
6SE6440-2AD27-5CA1 7.5 KW
6SE6440-2AD31-1CA1 11 KW
6SE6440-2AD31-5DA1 15 KW
6SE6440-2AD31-8DA1 18.5 KW
6SE6440-2AD32-2DA1 22 KW
6SE6440-2AD33-0EA1 30 KW
6SE6440-2AD33-7EA1 37 KW
6SE6440-2AD34-5FA1 45 KW
6SE6440-2AD35-5FA1 55 KW
6SE6440-2AD37-5FA1 75 KW

MM430 frequency converter
380~480V 3 ac Unfiltered without built-in filter
6SE6430-2UD27-5CA0 7.5 KW
6SE6430-2UD31-1CA0 11 KW
6SE6430-2UD31-5CA0 15 KW
6SE6430-2UD31-8DA0 18.5 KW
6SE6430-2UD31-8DB0 18.5 KW
6SE6430-2UD32-2DA0 22 KW
6SE6430-2UD32-2DB0 22 KW
6SE6430-2UD33-0DA0 30 KW
6SE6430-2UD33-0DB0 30 KW
6SE6430-2UD33-7EA0 37 KW
6SE6430-2UD33-7EB0 37 KW
6SE6430-2UD34-5EA0 45 KW
6SE6430-2UD34-5EB0 45 KW
6SE6430-2UD35-5FA0 55 KW
6SE6430-2UD35-5FB0 55 KW
6SE6430-2UD37-5FA0 75 KW
6SE6430-2UD37-5FB0 75 KW
6SE6430-2UD38-8FA0 90 KW
6SE6430-2UD38-8FB0 90 KW
6SE6430-2UD41-1FA0 110 KW
6SE6430-2UD41-1FB0 110 KW
6SE6430-2UD41-3FA0 132 KW
6SE6430-2UD41-3FB0 132 KW
6SE6430-2UD41-6GA0 160 KW
6SE6430-2UD41-6GB0 160 KW
6SE6430-2UD42-0GA0 200 KW
6SE6430-2UD42-0GB0 200 KW
6SE6430-2UD42-5GA0 250 KW
6SE6430-2UD42-5GB0 250 KW
380~480V 3 ac with filter with built-in filter
6SE6430-2AD27-5CA0 7.5 KW
6SE6430-2AD31-1CA0 11 KW
6SE6430-2AD31-5CA0 15 KW
6SE6430-2AD31-8DA0 18.5 KW
6SE6430-2AD32-2DA0 22 KW 22
6SE6430-2AD33-0DA0 30 KW
6SE6430-2AD33-7EA0 37 KW
6SE6430-2AD34-5EA0 45 KW
6SE6430-2AD35-5FA0 55 KW
6SE6430-2AD37-5FA0 75 KW
6SE6430-2AD38-8FA0 90 KW

MM420 frequency converter
208~240V 1/3 ac Unfiltered without built-in filter
6SE6420-2UC11-2AA1 0.12 KW
6SE6420-2UC12-A1 0.25 KW
6SE6420-2UC13-7AA1 0.37 KW
6SE6420-2UC15-A1 0.55 KW
6SE6420-2UC17-A1 0.75 KW
6SE6420-2UC21-1BA1 1.1 KW
6SE6420-2UC21-5BA1 1.5 KW
6SE6420-2UC22-2BA1 2.2 KW
6SE6420-2UC23-0CA1 3 KW
6SE6420-2UC24-0CA1 4 KW
6SE6420-2UC25-5CA1 5.5 KW
380~480V 3 ac Unfiltered without built-in filter
6SE6420-2UD13-7AA1 0.37 KW
6SE6420-2UD15-A1 0.55 KW
6SE6420-2UD17-A1 0.75 KW
6SE6420-2UD21-1AA1 1.1 KW
6SE6420-2UD21-A1 1.5 KW
6SE6420-2UD22-2BA1 2.2 KW
6SE6420-2UD23-0BA1 3 KW
6SE6420-2UD24-0BA1 4 KW
6SE6420-2UD25-5CA1 5.5 KW
6SE6420-2UD27-5CA1 7.5 KW
6SE6420-2UD31-1CA1 11 KW
208~240V 1 ac with filter with built-in filter
6SE6420-2AB11-2AA1 0.12 KW
6SE6420-2AB12-A1 0.25 KW
6SE6420-2AB13-7AA1 0.37 KW
6SE6420-2AB15-A1 0.55 KW
6SE6420-2AB17-A1 0.75
6SE6420-2AB21-1BA1 1.1
6SE6420-2AB21-5BA1 1.5
6SE6420-2AB22-2BA1 2.2
6SE6420-2AB23-0CA1 3
208~240V 1/3 ac with filter with built-in filter
6SE6420-2AC23-0CA1 3
6SE6420-2AC24-0CA1 4
6SE6420-2AC25-5CA1 5.5
380~480V 3 ac with filter with built-in filter
6SE6420-2AD22-2BA1 2.2
6SE6420-2AD23-0BA1 3
6SE6420-2AD24-0BA1 4
6SE6420-2AD25-5CA1 5.5
6SE6420-2AD27-5CA1 7.5
6SE6420-2AD31-1CA1 11

Options
6SE6400-0BP00-0AA0 BOP Basic Operation Panel -420/440
6SE6400-0BE00-0AA0 BOP2 Basic Operation Panel-430
6SE6400-0AP00-0AA1 AOP Operation Panel-420/440
6SE6400-0AP00-0AB0 Chinese AAOP Operation Panel-420/440
6SE6400-0EN00-0AA0 Encoder Pulse Encoder Counting Module
6SE6400-1PB00-0AA0 Profibus Communication Module
6SE6400-1CB00-0AA0 CANopen Communication Module
6SE6400-1DN00-0AA0 DeviceNet Communication Module
6SE6400-1PC00-0AA0 PC to inverter connection component-420/440
6SE6400-0PA00-0AA0 PC to AOP Connection Component
6SE6400-0DR00-0AA0 DIN Rail Installation Adapter
6SE6400-0GP00-0AA0 sealing cover-A size
6SE6400-0GP00-0BA0 Sealing Cover Plate - B Size
6SE6400-0GP00-0CA0 sealing cover plate - C size
6SE6400-0MD00-0AA0 AOP Multi control Cabinet Door Installation Component
6SE6400-0PM00-0AA0 BOP/AOP Cabinet Door Installation Component

Brake Resistors
6SE6400-4BC05-0AA0 6SE6400-4BC11-2BA0
6SE6400-4BC13-0CA0 6SE6400-4BC18-0DA0
6SE6400-4BC21-2EA0 6SE6400-4BC22-5FA0
6SE6400-4BD11-0AA0 6SE6400-4BD12-0BA0
6SE6400-4BD16-5CA0 6SE6400-4BD21-2DA0
6SE6400-4BD22-2EA0 6SE6400-4BD24-0FA0
6SE6400-4BD26-0FA0
Domestic local braking resistor
6SE6400-4BR11-0AA0 6SE6400-4BR12-0BA0
6SE6400-4BR16-5CA0 6SE6400-4BR21-2DA0
6SE6400-4BR22-2EA0 6SE6400-4BR24-0FA0

Filter Filter
6SL3000-0BE32-A0 6SL3000-0BE34-4AA0
6SL3000-0BE36-0A0
6SE6400-2FA01-4BC0 6SE6400-2FB00-6AD0
6SE6400-2FB01-4BC0 6SE6400-2FL01-0AB0
6SE6400-2FL02-6BB0 6SE6400-2FS01-0AB0
6SE6400-2FS01-6BD0 6SE6400-2FS02-6BB0
6SE6400-2FS02-5CB0 6SE6400-2FS03-8CD0

Import Input Choke
6SE6400-3CC02-2CD3 (replacing 6SE6400-3CC02-2CD0)
6SE6400-3CC03-5CD3 (replacing 6SE6400-3CC03-5CD0)
6SE6400-3CC04-4DD0 6SE6400-3CC05-2DD0
6SE6400-3CC11-2FD0 6SE6400-3CC11-7FD0
6SE6400-3CC00-2AD3 6SE6400-3CC00-3AC3
6SE6400-3CC00-4AB3 6SE6400-3CC00-4AD3
6SE6400-3CC00-C3 6SE6400-3CC00-6AD3
6SE6400-3CC00-8BC3 6SE6400-3CC00-0AB3
6SE6400-3CC01-0BD3 6SE6400-3CC01-4BD3
6SE6400-3CC01-7CC3 6SE6400-3CC02-6BB3
6SE6400-3CC03-5CB3 6SE6400-3CC08-3ED0
6SE6400-3CC08-8EC0 6SE6400-3CC32-3AA0
6SE6400-3CC32-8AA0 6SE6400-3CC33-3AA0
6SE6400-3CC35-1AA0
Domestic incoming line reactor Local input choke
6SE6400-3CR00-2AD3 6SE6400-3CR00-4AD3
6SE6400-3CR00-6AD3 6SE6400-3CR01-0BD3
6SE6400-3CR01-4BD3 6SE6400-3CR02-2CD3
6SE6400-3CR03-5CD3 6SE6400-3CR04-4DD0
6SE6400-3CR05-2DD0 6SE6400-3CR08-3ED0
6SE6400-3CR11-2FD0 6SE6400-3CR11-7FD0
6SE6400-3CR22-4FD0 6SE6400-3CR27-8FD0
6SE6400-3CR33-1GD0 6SE6400-3CR50-8GD0
Imported output reactor
6SE6400-3TC00-4AD2 6SE6400-3TC01-0BD3
6SE6400-3TC03-2CD3 6SE6400-3TC03-8DD0
6SE6400-3TC05-4DD0 6SE6400-3TC07-5ED0
6SE6400-3TC08-0ED0 6SE6400-2BE35-0AA0
6SE6400-3TC14-5FD0 6SE6400-2BE33-8AA0
6SE6400-3TC15-4FD0 6SE6400-2BE33-2AA0
6SE6400-2BE32-1AA0 6SE6400-2BE32-6AA0


Local direct sales, Zhejiang, Shanghai, Tianjin, Liaoning, Yunnan, Guangxi, Guangdong, Anhui, Beijing, Xinjiang, Chongqing, Hunan, Hubei, Hebei, Henan, Ningxia, Gansu, Shaanxi, Xizang, Guizhou, Sichuan, Hainan, Heilongjiang, Inner Mongolia, Shandong, Fujian, Shanxi, Jiangxi, Jiangsu

Siemens inverter MicroMaster440
The Siemens MicroMaster440 frequency converter is a new generation of multifunctional standard frequency converter that can be widely used. It adopts high-performance

Vector control technology provides low-speed high torque output and good dynamic characteristics, while also possessing * overload capacity to meet a wide range of applications

Occasion. The innovative BiCo (internal functional interconnection) feature has * flexibility. Main features: 200V-240V ± 10%,

Single phase/three-phase, AC, 0.12kW-45kW; 380V-480V ± 10%, three-phase, AC, 0.37kW-250kW; Vector control method

Can form closed-loop vector control and closed-loop torque control; High overload capacity, built-in braking unit; Three sets of parameter switching function.

Control functions: linear v/f control, square v/f control, programmable multi-point setting v/f control, flux current control without speed measurement vector control, closed

Loop vector control, closed-loop torque control, energy-saving control mode; Standard parameter structure, standard debugging software; Six digital inputs

Two analog inputs, two analog outputs, and three relay outputs; Independent I/O terminal board for easy maintenance; Using BiCo

Technology enables free connection of I/O ports; Built in PID controller, parameter self-tuning; Integrated RS485 communication interface, optional

PROFIBUS-DP/Device Net communication module; Has 15 fixed frequencies, 4 jump frequencies, programmable; Can achieve main/

From control and torque control methods; It has the function of 'automatic restart' when the power supply disappears or malfunctions; Flexible slope function occurs

Device with smooth characteristics of starting and ending segments; Fast current limiting (FCL) to prevent unnecessary tripping during operation; have

DC braking and composite braking methods improve braking performance. The overload capacity of the protection function is 200% of the rated load current, with a duration of 3

Seconds and 150% rated load current, with a duration of 60 seconds; Overvoltage and undervoltage protection; Inverter and motor overheat protection;

Ground fault protection, short circuit protection; Locking motor protection to prevent stall protection; Implement parameter linkage using PIN numbers.

Siemens inverter MicroMaster430
Siemens MicroMaster430 frequency converter is an expert in variable torque loads for fans and pumps in the new generation of standard frequency converters. power range

7.5kW to 250kW. It is designed according to requirements and uses internal functional interconnection (BiCo) technology, with high reliability and flexibility.

The control software can achieve functions such as multi pump switching, manual/automatic switching, bypass function, belt breakage and water shortage detection, energy-saving operation mode, etc

Main features: 380V-480V ± 10%, three-phase, AC, 7.5kW-250kW; Fan and pump type variable torque load specialist

Use; Robust EMC (electromagnetic compatibility) design; Fast response of control signals; Control function: Linear v/f control with flux current control (FCC) to enhance motor dynamic response and control characteristics, multi-point v/f control; Built in PID control

Equipment; Fast current limitation to prevent unnecessary tripping during operation; 6 digital inputs, 2 analog inputs, analog inputs

Output 2, relay output 3; Has 15 fixed frequencies, 4 jump frequencies, programmable; Using BiCo technology to achieve

Free connection of I/O ports; Integrated RS485 communication interface, optional PROFIBUS-DP communication module; Flexible slope function generator

, optional smoothing function; Three parameter switching functions: motor data switching, command data switching; Fan and pump functions

Multiple pump switching; Bypass function; Manual/automatic switching; Strip breakage and water shortage detection; Energy saving methods; Protection function: Overload capacity of 140% rated load current for 3 seconds and 110% rated load current for 60 seconds; Overvoltage and undervoltage protection; Inverter over temperature protection; Ground fault protection, short circuit protection; I2t motor overheat protection; PTC Y motor protection.

application field

MICROMASTER 430- Instructions

Do you need a frequency converter that can meet specific requirements without much effort? Using Siemens' MICROMASTER 420, this will not be a problem as it is a universal frequency converter suitable for three-phase power grids and can be connected via fieldbus. This type of frequency converter has a modular design, and various options can complement a wide range of standard functions. You only need to insert the operator panel and communication module without using any tools. Like other frequency converters in this series, the use of screw free control terminals makes terminal connections easy.

MICROMASTER 420- Instructions

Each task executed by the driving system has its own specific requirements. Therefore, it is necessary to provide a frequency converter solution that can be easily and flexibly adjusted to meet various challenges. Siemens' modular MICROMASTER 430 frequency converter possesses this flexibility. It is specifically designed for pumps and fans in the industrial field, capable of performing a wide range of tasks in similar applications. Compared to MICROMASTER 420, this frequency converter has higher energy efficiency, more inputs and outputs, and an optimized operator panel that can switch between manual and automatic operation modes.

MICROMASTER 440- Instructions

In the field of frequency converters, there are also some things that are difficult to control. It was not until the introduction of Siemens' functional frequency converter that the situation improved. MICROMASTER 440 is specifically designed for applications that require more extensive functionality and higher dynamic response than usual. These advanced vector control systems ensure high driving performance, even in the event of sudden load changes. Due to its fast response to input and ability to locate deceleration ramps, it is possible to move to the target position even without using an encoder. This frequency converter is equipped with an integrated brake chopper, which can work with outstanding accuracy even during braking and short deceleration ramp periods. All of these can be achieved within a power range of 0.12 kW (0.16 HP) to 250 kW (350 HP).


Siemens frequency converter

Wind Power Group is a supplier that can provide advanced wind power solutions for offshore, onshore, and coastal wind power projects.

As a purchaser in a company, it is necessary to pay attention to the following matters when selecting MM4 frequency converters for automation products,

Only by understanding the eight principles of selecting MM4 frequency converters can enterprises choose better MM4 frequency converters.


1、 The actual motor current value is used as the basis for selecting the frequency converter.

When choosing MM4 frequency converter, full consideration should be given to the high output high-order harmonic ratio of the frequency converter,

High order harmonics can deteriorate the power factor and efficiency of electric motors.

Therefore, when choosing electric motors and frequency converters, this situation should be taken into consideration, and appropriate margins should be left to prevent excessive temperature rise and affect the service life of the electric motor.


2、 Select a frequency converter based on load characteristics. If the load is a constant torque load, a Siemens MM4 frequency converter should be selected,

If the load is a fan or pump, an MM430 frequency converter should be selected.


3、 Measures should be taken to suppress the impact of long cable on ground coupling capacitance and avoid insufficient output of the frequency converter when it is necessary to operate a long cable frequency converter.


4、 For some high environmental temperatures, high switching frequencies (especially when used in applications with high noise restrictions such as building automation), high altitudes, etc

At this point, it will cause a reduction in the capacity of the frequency converter, and the frequency converter needs to be amplified by one level for selection.

If the power supply of the frequency converter is a self-contained power supply, with an inlet reactor added.


5、 When using a frequency converter to drive a gear reduction motor, the application range is limited by the smooth method of gear transformation.

When the oil is smooth, there are no constraints in the low-speed range; There is a risk of running out of smooth oil in the high-speed range beyond the additional speed.

Therefore, do not exceed the allowable value of Z high speed.


6、 When driving a wound rotor asynchronous motor with a frequency converter, most existing motors are used.

Compared with conventional squirrel cage motors, wound motor windings have lower impedance.

Therefore, it is easy to experience overcurrent tripping due to ripple current, so a frequency converter with slightly larger capacity than usual should be selected.

Usually, wound motors are used in situations where the flywheel torque GD2 is large, and more attention should be paid when setting the acceleration and deceleration time.


7、 When driving a synchronous motor with a frequency converter, the output capacity will decrease by 10% to 20% compared to the power supply,

The continuous output current of the frequency converter should be greater than the product of the additional current of the synchronous motor and the standard value of the synchronous traction current.


8、 Regarding loads with large torque fluctuations such as compressors and vibration machines, as well as peak load conditions such as hydraulic pumps,

If the frequency converter is selected based on the additional current or power value of the motor, there is a possibility of overcurrent maintenance measures due to peak current.

Therefore, it is necessary to know the operating conditions of the power frequency and select a frequency converter with an additional output current greater than its Z current.