Yokogawa Yokogawa Industrial Gas Chromatography System
GC8000
The GC8000 has a built-in 12 inch color touch screen, greatly simplifying maintenance work. As long as you touch the screen, all analysis parameters and measurement results will be presented in a simple and understandable graphical form on the color display screen for technicians to refer to.
GC8000 also has many significant innovations in the analytical capabilities of gas chromatography. Due to the adoption of the GC unit (GCM) concept, the practicality of parallel analysis has been achieved. By setting multiple virtual chromatograms in a single analyzer, the settings, displays, and data of all chromatograms are made independent, making it easy to understand and maintain. Moreover, the built-in graphical overview screen can be used to view each GC unit.
GC8000 provides hardware and electronic technologies that have been validated in terms of reliability and operability, while also taking the application of industrial gas chromatography to a higher level through its multi oven analysis capability.
The communication network of GC8000 is based on the industrial standard Ethernet structure, which ensures flexible and secure transmission of data to the gas chromatograph maintenance station and factory DCS system. GC8000 can be configured with either a single Ethernet or a redundant network using two isolated Ethernet networks.
feature
Multi constant temperature furnace structure for high-speed analysis
Large touch screen improves operational performance
Highly reliable
performance improvement
specification
Measurement object gas or volatile liquid (boiling point of 400 ℃ or below)
Analysis method: Gas chromatography
The measurement range depends on the analysis conditions
TCD: 1ppm~100%
FID: 1ppm~100%
FID (with methane converter): 1ppm~0.1%
FPD: 1ppm~0.1%
The measurement group score is 999 (including the total number of components in all calibrated flow paths)
Analysis cycle is 21600.0 seconds (6 hours) long
31 measurement channels (including calibration channels)
Contact material RV: 316SS, Hastelloy C, Rulon, PTFE (PTFE) Bearee)
LSV:316SS、 Hastelloy C, Rulon, glass, PTFE (Teflon) Bearee)、 Fluororubber (Viton), Perfluorinated Rubber (Kalrez)
Repeatability depends on the analysis conditions
Gas sample: ± 1% (2 σ) of full scale
Liquid sample: ± 2% (2 σ) of full scale
*According to different specifications and conditions, there may be differences. For detailed information, please consult Yokogawa Electric Corporation.
Analyzer specifications
Protection type: positive pressure and explosion-proof structure, or non explosion proof structure
Explosion proof grade FM and CSA:
Type X Pressurization and Explosionproof for Class I,
Division 1,Groups B, C and D. T1~T4
Type X and Y Pressurization for Class I,
Division 1,Groups B, C and D. T1~T4
ATEX: II2G Ex d px IIB+H2 T4...T1 Gb
IECEx: Ex d px IIB+H2 T1...T4 Gb
TIIS: Ex pd IIB+H2 T1~T4
Construct NEMA3R, equivalent to IP54 (dustproof and anti drip structure)
Operating environmental conditions -10~50 ℃, 95% RH or below (no condensation)
weight
Wall mounted independent type
Type 1 weighs approximately 100kg and 140kg
Type 2 weighs approximately 155kg and 190kg
Type 3 weighs approximately 200kg and 220kg
Constant temperature furnace
Large capacity constant temperature furnace: approximately 45L
Standard constant temperature furnace: approximately 31L
Temperature setting range: 55-225 ℃ (set in units of 1 ℃)
Temperature control accuracy ± 0.03 ℃
Temperature control method PID control
Input
Analog input/output with an additional 16/32 points
Contact input/output large 32/20 points
PC Communication Ethernet Communication
Protocol: TCP/IP, FTP, Modbus CP/IP
DCS communication RS-422
Protocol: MODBUS, Y-Protocol
Common parts
Power supply 100/110/115/120/200/220/230/240VAC ± 10%,
50/60Hz±5%
Power consumption type 1: 1.2-1.6kVA
Type 2: 2.0-2.5kVA
Type 3: 3.0-3.7kVA
instrument air
Pressure: 350-900kPa
Flow rate: Type 1: 100-140L/min
Type 1 with FPD: 130-200L/min
Type 2: 150-210L/min
Type 2 with FPD: 180-270L/min
Type 3: 200-280L/min
carrier gas
Type: H2, N2, He or Ar
Purity: Measurement range 0-50ppm or higher:
99.99% lower
(Water: 10ppm or less; Organic components: 5ppm or lower)
Measurement range 0 to below 50ppm:
99.99% lower
(Water: 5ppm or lower; Organic components: 0.1ppm or lower)
Pressure: H2: 500kPa (72.5psi) (To meet explosion-proof requirements, additional pressure reducing valves need to be installed for gas supply)
Other gases: 400-700kPa
Consumption: 60-300mL/min per constant temperature furnace