YT-TQT100 Desktop Pressure Calibration Platform

NegotiableUpdate on 05/20
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The pressure calibration station is a vacuum calibration station that combines vacuum and air pressure, consisting of three parts: a relief valve, a pressure generating system, and a pressure output. It can provide a pressure source for verifying pressure (differential pressure) transmitters, precision pressure gauges, ordinary pressure gauges, and other pressure instruments. Can be used in conjunction with pressure standards to complete testing and calibration work. Due to its open and transparent structure, users often overlook the convenience of maintenance and upkeep when selecting models

Product Details

The pressure calibration station is a vacuum calibration station that combines vacuum and air pressure, consisting of three parts: a relief valve, a pressure generating system, and a pressure output. It can provide a pressure source for verifying pressure (differential pressure) transmitters, precision pressure gauges, ordinary pressure gauges, and other pressure instruments. Can be used in conjunction with pressure standards to complete testing and calibration work. Due to its open and transparent structure, users often overlook the convenience of maintenance and upkeep when selecting models

Technical Specifications:

1. Pressure range: -0.095 to 6MPa

2. Operating temperature: (0-50 ℃)

3. Adjust fineness: 1Pa

4. Pressure medium: clean air

5. Weight: 7.5Kg

6. Volume: 410X355X180 (mm)

Notes:

1. The device should be used within the rated pressure range as much as possible and should not be used beyond the range.

2. The pressure/vacuum conversion must be carried out in a non pressure state.

3. The calibration table should be placed on a stable operating platform to avoid entering environments with corrosive gases and dust particles.

4. If not used for a long time, the equipment should be stored in a dry, non corrosive gas environment;

5. Leverage pressure, apply even force, do not use force when closing or opening the valve.

6. Regularly clean the impurities inside the filter to prevent them from affecting the service life of the equipment