1、 Product Introduction
YSI 55 dissolved oxygen and temperature measuring instrumentIt is a multi parameter measuring instrument that can be operated by hand and has a stainless steel probe under field conditions. The YSI 55 dissolved oxygen and temperature measuring instrument from the United States uses an integrated probe and cable. Backlight display, long battery life.
2、 Product Features
Handheld operation, can also be hung on the shoulder or waist
Stainless steel probe, capable of withstanding more severe field conditions; Additionally, the weight of the metal makes it easier for the probe to sink into the water
Available in three cable lengths of 3.7 meters, 7.5 meters, and 15 meters for selection
Full button calibration and operation, all operations are controlled by a microprocessor
Simultaneously display dissolved oxygen and temperature readings, with the option to display air saturation or milligrams per liter concentration
Can directly input salinity to compensate for the deviation of dissolved oxygen in different water bodies
Height can be directly input to compensate for the deviation of dissolved oxygen caused by air pressure at different heights
The cable joint is equipped with a stress reliever to reduce material fatigue at the connection point and effectively extend the service life of the cable
YSI 55 dissolved oxygen and temperature measuring instrumentBuilt in calibration room for easy air calibration; The calibration room can also serve as a probe storage room at the same time
Extra large LCD display screen with background lighting function, allowing clear reading even in dim environments
Full battery operation, with a working life of up to 100 hours (alkaline battery); There is also a low battery display
3、 Technical parameters
technical indicators | |||
ginsengnumber |
measurement range |
resolution |
accuracy* |
溶solutionoxygen |
0to200%air saturation |
0.10%air saturation |
±2%air saturation* |
0to20milligram/rise |
0.01milligram/rise |
±0.3milligram/rise* |
|
warmdegree |
-5℃ to+45℃ |
0.1℃ |
±0.4℃* |
Salinity compensation |
0to40ppt |
||
high compensation |
0to3000rice |
||
rulerinch |
24.1Centimeter (height)×8.9Centimeter (width)×5.0Centimeter (thickness) |
||
heavyquantity |
0.73kilogram |
||
* The instrument specifications include the total error of the instrument and probe | |||
Buying Guide | |
andceremonydevice | |
55-12 |
55typeDissolved oxygen and temperature measuring instruments,3.7Rice cable |
55-25 |
55typeDissolved oxygen and temperature measuring instruments,7.5Rice cable |
55-50 |
55typeDissolved oxygen and temperature measuring instruments,15Rice cable |
55D |
55DtypeDissolved oxygen and temperature measuring instrument (without probe) |
DType probe |
|
55D-12 |
Detachable dissolved oxygen/Temperature probe,3.7Rice cable |
55D-25 |
Detachable dissolved oxygen/Temperature probe,7.5Rice cable |
55D-50 |
Detachable dissolved oxygen/Temperature probe,15Rice cable |
matchdocument |
|
5050 |
Carrying case, hardware |
5520 |
Plastic portable case (capable of accommodating)7.5Meter cable) |
薄membrane |
|
5685 |
Semi sensitive membrane(30piece) |
5775 |
Standard film(30piece) |
5576 |
High sensitivity membrane(30The film,) |
5793 |
Standard film(150Film) |
5794 |
High sensitivity membrane(150Film) |
Note: Standard film is suitable for the vast majority of situations. High sensitivity membranes can be used at low temperatures or low dissolved oxygen levels; On the contrary, when the dissolved oxygen level is very high or requires slightly longer monitoring, a semi sensitive membrane can be used. | |