YNFDJ-1000 intelligent automatic charging and discharging motor for battery pack
YNFDJ-1000 intelligent automatic charging and discharging motor for battery packSuitable for automatic charging and discharging detection of batteries in industries such as communication, power, and rail transit (railway, high-speed rail, subway, light rail). This product integrates battery constant current and constant power discharge, individual monitoring (optional), and intelligent charging; One machine with multiple uses reduces enterprise costs, lowers the labor intensity of maintenance personnel, and provides comprehensive and scientific testing methods for battery maintenance, making it a beneficial assistant for battery maintenance work.
1. It integrates four functions: charging, discharging, individual voltage detection, and whole group activation. It is fully functional and versatile.
2. The charging and discharging voltage range is wide, the single machine current is large, and it can charge and discharge different types of lead-acid batteries and alkaline batteries. It can be used for multiple purposes, reducing enterprise costs and lowering the labor intensity of maintenance personnel.
3. Seven inch color touch LCD display, with clear and beautiful display effect; The fully Chinese human-machine dialogue interface is easy to read and operate, beautiful and practical, and user-friendly.
4. Constant current discharge, intelligent three-stage automatic charging, real-time online detection of the voltage of each individual battery, can set parameters such as voltage, current, time, capacity, etc., and automatically complete various tests of the battery pack according to the set parameters.
5. During the charging and discharging process, parameters such as charging and discharging current, voltage, capacity, and time can be modified without exiting the charging and discharging operation to charge and discharge according to the newly modified parameters. During the charging and discharging process, manual intervention can be used to terminate the charging and discharging.
6. Having multiple safety protection measures: reversing the polarity of the charging and discharging cables, the reverse connection indicator light will light up and emit an alarm sound; If the charging and discharging current exceeds the set value, the voltage is higher or lower than the set value, and the temperature is abnormal, the equipment can automatically alarm and stop charging and discharging.
7. You can view the column chart of individual batteries in real-time, and after testing is completed, you can directly view the individual cell curve and the comparison chart with the reference curve.
8. During the testing process, if there is a sudden power outage or prolonged disuse, the memory data in the host will not be lost. Can save 10 sets of charging, 10 sets of discharging, and 10 sets of online monitoring data; Users can perform query, deletion, and SD card export operations.
9. The upper computer data management software has user-friendly interface and provides functions such as data management, printing, analysis, report statistics, and automatic generation of test reports.
10. It has a quick connection function and is easy to operate and use.
1. Public parameters:
| display mode | 7-inch color touch LCD display |
| Discharge load | Alloy resistance (with good safety) |
| charging unit | Intelligent high-frequency switching power supply |
| cooling method | Forced air cooling type |
| battery type | Lead acid battery, alkaline battery |
| Charge and discharge detection method | The battery pack is disconnected from the original system |
| Accuracy of charging and discharging current | (Resolution 0.1A, Accuracy 1A) |
| Accuracy of charging and discharging voltage | (Resolution 10mV, accuracy 0.1V) |
| Discharge termination conditions | Lower limit of overall voltage, lower limit of individual voltage (multiple sections can be set), discharge time, discharge capacity, manual termination |
| Charging termination conditions | Upper limit of overall voltage, upper limit of individual voltage (multiple sections can be set), charging time, charging capacity, manual termination |
| Single cell voltage monitoring range (optional) | 0.500V~16.00V (resolution 1mV, accuracy 10mV) |
| Charging and discharging time | 0-99 hours and 59 minutes can be set |
| Number of charging and discharging cycles | 1 to 9 times can be set |
| Charging and discharging interval time | 1 minute to 99 hours can be set |
| Data storage space | Built in 256M+external 4G (standard) SD card, optional storage location |
| Alarm generation and safety measures | Test cable polarity reversal; The charging and discharging current exceeds the set value; Voltage above or below the set value; Abnormal temperature; The equipment can automatically sound an alarm and stop discharging in case of fan failure, etc. |
| data analysis software | Can start online testing and conduct real-time monitoring |
| Data analysis and printing project | Dynamic data display and printing of settings and measured items such as charging and discharging voltage, charging and discharging current, charging and discharging time, charging and discharging capacity, and individual capacity. |
| Operating Temperature | -20~55℃ |
| relative humidity | 90%(40±2℃) |
| atmospheric pressure | (70~106)kPa |
2. Selection parameters:
| product category | communication | electricity | UPS | Wide voltage range type (Customized type) |
Railway, subway and other industry types |
| Voltage type of battery pack | 48V | 110V/220V | 380V/450V/600V | 10~300V | 10~120V |
| MAX charging and discharging current | 50A/100A/150A | 30A/40A/50A/60A/80A/100A | 30A/50A | 0~ 50A | 0~ 100A |
| Charging and discharging voltage range | 30~60V | 110V:90~180V 220V:180~260V |
380V:300~450V 450V:380~500V 600V:450~650V |
10~300V | 10~120V |
| Number of individual batteries | Configure according to the actual number of sections (single cell voltage monitoring function can be turned off) | ||||
| working power supply | AC:220V | AC:220V | AC:220V | AC:220V | AC:380V |
| charging power supply | AC:380V | AC:380V | AC:380V | AC:380V | AC:380V |
| Transportation method | Roller Mobile Portable | Roller Mobile Portable | Roller Mobile Portable | Roller Mobile Portable | Cabinet fixed installation type |
| host size | 590㎜×340㎜×600㎜ | 590㎜×340㎜×600㎜ | 400㎜×500㎜×800㎜ | 770㎜×435㎜×820㎜ | 600㎜×600㎜ ×1850 ㎜ |
| host weight | 45 Kg | 45Kg | 50 Kg | 60 Kg | 230Kg |
| packaging method | wooden box | ||||
| package weight | 60Kg | 60Kg | 65Kg | 75Kg | 230Kg |
| mode of transportation | Railway and automobile transportation | ||||