- Phone
-
Address
No. 80 Zhucun Avenue West, Zhucun Street, Zengcheng District, Guangzhou City
Guangzhou Wenlai Instrument Co., Ltd
No. 80 Zhucun Avenue West, Zhucun Street, Zengcheng District, Guangzhou City
XSM/A-H1MT1A1B1V0N Speed Controller
XSM/C-H1GT2A1B1S0V0 tachometer function parameter description:


XSM/A-H1MT1A1B1V0N Speed Controller

Product Description:
① Connect various proximity switches, encoders, or pulse signals. Measure rotational speed, frequency, and line speed within a frequency range of 0.1Hz to 25kHz, with a basic error of ± 0.02%, displayed on a 5-digit LED
② Dimensions: 160 * 80 (horizontal), 96 * 48 (horizontal), 96 * 96 (square)
③ Instrument power supply 220V AC, (9~30) V DC
Basic configuration:
Single display, external sensor power supply (≥ 50mA)
Extended functions:
① Alarm output: 4 extra points for 160 × 80 specifications, 2 extra points for 96 × 48 specifications
② Transmission output
③ Communication interface: RS 232 or RS 485
Selection Table
content |
Code Description |
||||||||||||||
XSM/ |
Single display, external sensor power supply (≥ 50mA) |
||||||||||||||
|
appearance size |
A— |
160(W)×80(H)×125(L) |
|||||||||||||
B— |
96(W)×96(H)×112(L) |
||||||||||||||
C— |
96(W)×48(H)×112(L) |
||||||||||||||
Panel form |
H |
horizontal format |
|||||||||||||
F |
square |
||||||||||||||
|
display mode (The color of LED display shall be in accordance with the order requirements) |
1 |
Measurement value (green) |
|||||||||||||
2 |
Measurement value (green)+set value (red) (limited to A-type instrument) |
||||||||||||||
3 |
Measurement value (green)+measurement value light column (green) (limited to A-type instruments) |
||||||||||||||
input signal |
G |
Standard type. Suitable for NPN, PNP voltage pulses, (4~20) mA2 limited pulses, TTL pulses, etc |
|||||||||||||
M |
MV type, suitable for magneto electric proximity switches |
||||||||||||||
Number of alarm points |
T□ |
T0: No alarm T1~T8:1~8 point alarm |
|||||||||||||
|
transmitter output (Independent power supply, fully isolated. 10 bit D/A, error less than ± 0.5%, or 12 bit D/A, error less than ± 0.2%) |
A0 |
No output |
|||||||||||||
A1 |
Current output (4~20) mA, (0~10) mA, or (0~20) mA |
||||||||||||||
A2 |
Voltage output (0~5) V, (1~5) V |
||||||||||||||
A3 |
Voltage output (0~10) V |
||||||||||||||
A4 |
Other outputs |
||||||||||||||
External power supply |
B0 |
No external power supply |
|||||||||||||
B1 |
External supply 24V DC, error less than ± 5%, 50mA |
||||||||||||||
B2 |
External supply 12V DC, error less than ± 5%, 50mA |
||||||||||||||
B3 |
other |
||||||||||||||
communication interface |
S0 |
No communication interface |
|||||||||||||
S1 |
RS-232 interface |
||||||||||||||
S2 |
RS-485 interface |
||||||||||||||
S3 |
RS-422 interface |
||||||||||||||
S4 |
BCD code interface (limited to A and B type instruments) Note 2 |
||||||||||||||
instrument power supply |
V0 |
220V AC |
|||||||||||||
V1 |
24V DC |
||||||||||||||
V2 |
12V DC |
||||||||||||||
V3 |
other |
||||||||||||||
Printing function (limited to A and B type instruments) |
P |
P represents the printing interface, which can be omitted if not included |
|||||||||||||
Pre division unit |
F* |
F * represents the pre frequency division unit, which can be omitted if not included. |
|||||||||||||
Non standard functions |
N |
N represents non-standard function |
|||||||||||||
Example of selection: