XMTA-1000 series intelligent PlD regulator

NegotiableUpdate on 07/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Overview: The OW-XMTA series intermittent or continuous PID regulator can have up to 5 switch outputs, including one dedicated to controlling the input part's resistance, coupling, and disconnection, and the other 4 for switch, control, or programmable dual timers, counters, or programmable intelligent sound and light alarms

Product Details

summary
OW-XMTAThe series of intermittent or continuous PID regulators can have up to 5 switch outputs, one of which is dedicated to controlling the breaking resistance, breaking coupling, and breaking of the input part, and the other 4 are used for switch, control, or programmable dual timers, counters, or programmable intelligent sound and light alarms.
XMTAA series of intermittent or continuous PID regulators can output the PID continuous control quantity, input process quantity, setpoint, valve position feedback quantity, etc. in analog form from the instrument. The same quantity can be given to any one or two analog output ports. The instrument can have up to 3 analog output ports. When ordering the instrument, please specify the quantity and purpose of the analog output ports. Each analog output port can be defined as 0~10mA or 4~20mA by the user.
◆ Characteristics
Various analog inputs or frequency inputs can also be subjected to square root and small signal cutoff (specified when ordering).
● Triple display of process quantity indication, given value, and control quantity indication.
● PID regulation positive and negative action selection.
● Manual automatic bidirectional undisturbed cutting and manual automatic status indication.
● Process quantity (transmitter with adjustable measurement interval and reverse action) analog output.
Both intermittent and continuous PID regulators can control analog output.
● Set the analog output to 0~10mA or 4~20mA at will.
The action pattern of each positional control point can be set in 8 different ways (such as upper limit alarm, lower limit alarm, absolute value alarm, etc.)
● Output faults such as broken resistance, broken couple, and broken wire.
The automatic adjustment of proportion P, the adjustment of re adjustment time I, and the adjustment of pre adjustment time d are the adjustment methods I.
PID parameter self-tuning or independent self-tuning of P parameter.
● Control upper limit and lower limit output control range can be set separately.
● Power on automatically or manually (manual output value can be preset).
● Manual and automatic status indication and output.
● Simulate output with internal given value (specified when ordering).
● Two or three analog outputs (specify when ordering).
● The first analog output can be set as frequency output mode (full scale is 3~10000Hz).
One switch can be set to selectively monitor the other two switch values, achieving intelligent sound and light alarm function with silencing time (specified when ordering).
The third and fourth set values can be combined to achieve organic control of a relay, simplifying the external wiring or components of the instrument and reducing the occupation of internal hardware resources. If there are different controls for water pumps or sewage pumps (please specify the associated method when ordering).
The 50Hz synchronous bidirectional thyristor zero crossing compensation control algorithm is used to achieve optimized control of each sine wave, avoiding high-order harmonic pollution of the power grid caused by high-power loads.
● Remote switch quantity control set value displacement (SP=SP1 ± P1h or=SP4).
The intermittent PID regulator instrument can directly control single-phase resistive loads with AC power below 2KW or output 3 sets of synchronous signals triggering bidirectional thyristors below 500A for users with built-in 40A bidirectional thyristors.
8 sets of given values SP1 and P, I, D parameter storage and calling.
The control output of the remote switch quantity control regulator is PID regulation mode or hold state, with bidirectional disturbance free switching.
● Set the given values and PID parameters online without disturbance.
The control input and output of the remote switch quantity control regulator are PID regulation mode or tracking state, with bidirectional disturbance free switching.
Main technical indicators
1Display mode: Full 4-digit even number display indicator, accuracy level 0.5.
2Resolution: Last word
3Analog output accuracy: Level 0.5
4Current signal: ≤ 50 Ω; Voltage signal: ≥ 500K Ω; Frequency signal: ≥ 10K Ω
External resistance of thermal resistor: ≥ 10 Ω; Thermocouple signal: ≥ 500K Ω
5Switching input impedance: The internal pull-up resistors at the EM1 and EM2 terminals of the instrument are 10 Ω, and the low level (≤ 0.8V) is effective
6Analog output driving load impedance:
Current signal: 0~10mA ≥ 1.5 K Ω; 4~20mA ≥ 750 K Ω;
Voltage signal: 0~5V, 1~5V output impedance ≤ 1 Ω
7Switching output: AC 220V, 3A (impedance load)
8The parameter retention time set after power outage: ≥ 20 years
9Insulation strength: AC voltage 1500V, 1 minute
10Insulation impedance: above 50M Ω
11Environmental temperature: 0~50 ℃
12Compared to temperature: ≤ 85%
13Voltage: AC 220V, 50Hz
14Allowable power supply voltage variation: ≤± 10%
15Power consumption: ≤ 6VA
◆ Selection method
OW-
enterprise standard
model
XMTA
Digital display instrument (analog input) (artificial intelligence, enhanced)
DesIgn Serial Number
1
Input function
0
Linear resistance: 0-400 Ω
1
Thermocouple indexing numbers: K, E, S, B, J, T, N, EA
2
Thermal resistance index numbers: Pt100, BA1, BA2, Cu100, Cu50
3
Linear current: 0-10 mA, 4-20mA
4
Linear voltage: 0-20mV, 10-100mV, 0-500mV, 0-5V, 1-5V
5
Two wire transmitter: 4-20mA
6
Frequency signal: 0.01-1000Hz
9
Full signal input (including all 1-5)
output function
0
No analog output
1
4-20mA、 DC 1-5V
2
0-10mA、 DC 0-5V
3
1-5VDC
4
0-5VDC
Alarm
0
No alarm
1
Alarm all the way
2
Two way alarm
3
Three way alarm
9
Four way alarm
Instrument functions
1
Continuous PID current voltage output
2
Intermittent PID
3
Time proportion adjustment control
4
PIDGiven output in and out of band
External dimensions
B
Panel size 160 × 80 with openings 152 × 76
F
Panel size 96 × 96 with openings 92 × 92
H
Panel size 80 × 160 with openings 76 × 152
I
Panel size 72 × 72 with openings 68 × 68
L
Panel size 48 × 96 with openings 44 × 92
S
Panel size 96 × 48 with openings 92 × 44
External power output
N
No feed output
P
There is a 24V DC output
communication model
0
No communication
1
RS485/RS232communication interface
Additional features (optional multiple)
U
Conventional instruments (can be omitted)
G
ordinarybeamindicate
S
Dual signal input
K
Opening method display
Power supply mode
W
DC 24Vpower supply
T
switch power supply
M
220V/AC(Can be omitted)