Welcome Customer !

Membership

Help

Jinhu Ouwang Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Jinhu Ouwang Technology Co., Ltd

  • E-mail

    jhowkj@163.com

  • Phone

    15952326780

  • Address

    No. 48-11 Jinhu Road, Jinhu County, Jiangsu Province

Contact Now

XMJA series intelligent flow integrator

NegotiableUpdate on 07/24
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Overview: Our OW-XMJA-9000 series intelligent flow integrator integrates most of the functions of various flow integrators in current automatic control systems, supplemented by a software system that draws on the strengths of others, carefully developed, and repeatedly debugged

Product Details



◆ Overview
Our OW-XMJA-9000 series intelligent flow integrator integrates most of the functions of various flow integrators in current automatic control systems, supplemented by a software system that draws on the strengths of others, carefully developed, and repeatedly debugged.
◆ Characteristics
The hardware of the instrument has been significantly reduced, and the composition structure of the system is relatively simple. Within the scope of user application, multiple input signals can be switched freely. Adopting optimized design, the process has been significantly improved, without flying wires or adjusting potentiometers. All calibration and function settings can be completed by software through the keyboard.
Up to four alarm outputs can be set, with more than ten alarm methods and monitoring of alarm parameters.
Two display windows, four display windows display instantaneous flow values, six display integrated values, and the actual effective integrated value is seven or nine. The P-type also has a dual reset function of external reset and internal reset (which can be viewed by setting the conversion coefficient).
◆ Function
Input signals: standard linear signal, Pt100 thermistor, frequency signal.
Square opening and small signal resection are possible. 8 compensation points and parameters.
● 4Reset the instantaneous flow value and cumulative flow value to zero.
Programmable quantitative flow calculation, capable of batch and quantitative control.
Transmission output: 0-100mA or 4-20mA
Instantaneous and cumulative flow control output with adjustable values.
Two flow signals can be mixed in proportion to display instantaneous flow and accumulate flow, and two analog outputs can be selected simultaneously.
Dual flow accumulation control, dual-mode analog transmission. Batch and quantitative control is possible.
After the instrument relay, the parameters and cumulative flow values can be saved for 200 years.
RS485 asynchronous serial communication can be provided in multi-party, single host, and no host modes. Communication data verification follows CRC-16 US data communication standard, high reliability cycle, barcode verification
Main technical indicators
Measurement accuracy: ± 0.5% FS+1 word
Adjustment control accuracy: Position: ± 0.5% FS
Alarm function: upper limit, lower limit, upper and lower limits, lower loop difference, double loop difference, OK mode, absolute value mode, etc
Transmission output accuracy: ± 0.5% FS Load capacity: 0-600 Ω
Input impedance: 0-10mA: 500 Ω, 4-20mA: 250 Ω, DC. V ≥ 200K Ω, pulse amplitude: ≥ 2.5V, frequency range: 0.01-10000Hz
Relay contact capacity: AC220V 2A
Power supply: AC220V ≤ 6W AC110V DC24V
Work environment requirements: temperature: 0-50 ℃, relative humidity:<85%, no corrosive gases, low vibration allowed
◆ Selection method
OW
enterprise standard
Separation line
Model number
9
Digital display flow accumulation instrument (artificial intelligence, enhanced)
DesIgn Serial Number
9
Input function
0
Linear: mV signal
5
Linear: mA signal
6
Linear: V signal
7
Compatible with all signals
9
Frequency pulse signal
output function
0
no-output
1
4~20mA or 1-5V
2
0~10mA or 1-5V
Alarm
0
No alarm
1
Alarm all the way
2
Two way alarm
3
Three way alarm
9
Four way alarm
External dimensions
B
Panel size 160 × 80 with openings 152 × 76
F
Panel size 96 × 96 with openings 92 × 92
H
Panel size 80 × 160 with openings 76 × 152
External power supply
N
No feed output (can be omitted)
P
There is a 24V DC output
Compensation method
0
Normal flow method, without temperature or pressure compensation
1
Pressure compensation method using voltage or current signals for saturated steam
2
Temperature compensation method using voltage or current signals for saturated steam
3
Temperature compensation method using Pt100 thermal resistor for saturated steam
4
Temperature and pressure compensation method using voltage or current signals for saturated steam
5
Superheated steam is compensated for pressure using voltage or current signals, and temperature compensation using Pt100 thermal resistors
6
Excluding temperature and pressure compensation, with display conversion system settings
7
Capable of compensating for both temperature and pressure simultaneously
Power supply mode
W
DC 24Vpower supply
T
Switching power supply 85-265V.AC
M
220V.AC(Can be omitted)