Welcome Customer !

Membership

Help

Haohan Chromatography (Shandong) Application Technology Development Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Haohan Chromatography (Shandong) Application Technology Development Co., Ltd

  • E-mail

    2875161531@qq.com

  • Phone

    13963221227

  • Address

    Honghe Avenue Smart Trade City

Contact Now

Workplace air toxic substance - determination of acetic anhydride - chromatographic column

NegotiableUpdate on 02/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Workplace air toxic substance acetic anhydride determination chromatography column; Suitable for: Agilent 490 online/portable, 489058906890782088608890 Shimadzu GC-14C, GC-2010, GC-2014, GC-2030 $r $n $r $n $r $n Thermo Fisher Scientific 1310130016101600 $r $n $r $n Varian 3800 series $r $n $r $n Bruker PE580590680690
Product Details

Workplace air toxic substance - determination of acetic anhydride - chromatographic column Detailed information:


GBZ/T 160.60-2004 Determination of Toxic Substances in Workplace Air - Anhydride Compounds
This standard is replaced by GBZ/T 300.118-2017 Determination of Toxic Substances in Workplace Air Part 118: Acetic Anhydride, Maleic Anhydride, and Phthalic Anhydride
This standard specifies the method for monitoring the concentration of anhydride compounds in the air of the workplace.
This standard is applicable to the determination of the concentration of anhydride compounds in the air of the workplace.


Name: Filler Column

Fixed phase: porous polymer support of 2,6-diphenyl-p-phenylether

Specification: 2m * 4mm

Material: Glass Column/Stainless Steel

Model: Tenax

Application:

GBZ/T 160.60-2004 Determination of Toxic Substances in Workplace Air - Anhydride Compounds

GBZ/T 300.118-2017 Determination of Toxic Substances in Workplace Air Part 118: Acetic Anhydride, Maleic Anhydride, and Phthalic Anhydride


Suitable for:

Agilent 490 online/portable, 48905890689088608890

Shimadzu GC-14C, GC-2010, GC-2014, GC-2030

Thermo Fisher Scientific 1310130016101600

Varian 3800 Series

Brooke PE580590680690

Panno A90, Fuli GC9790, Huaai, Tianrui, Tianmei, GC7900, Chuanyi, Beifen Ruili, Dongxi Electronics, Lunan Ruihong, Jiedao/Kexiao



Haohan Chromatography (Shandong) Application Technology Development Co., Ltd., research and production《Workplace air toxic substance - determination of acetic anhydride - chromatographic column 》In Agilent, Shimadzu, Thermo Fisher, Varian, Brooke, PE, The separation is good and the effect is satisfactory.





Each chromatographic column undergoes rigorous testing

Complete range of chromatographic column types

Technical Support

Years of accumulated rich experience and technical team in chromatographic analysis


Using high-quality stainless steel tubes, glass tubes, and chromatographic fillers to produce various packed chromatographic columns

If you need to use stainless steel filter mesh as the plug at both ends of the column, please indicate it when ordering

If a column is used for sampling, there will be a space of 6CM at the front end of the column entrance,

To prevent the chromatographic packing from flowing out, both ends of the column are sealed with silanized glass wool

If a chromatographic column with valve injection or non column injection is used, the inlet of the column is filled

Can provide glass column configurations for various models of gas chromatographs

The inlet of the 2mm inner diameter glass column tube is equipped with a sloping surface for sample injection

Each chromatographic column undergoes thorough aging and rigorous quality evaluation testing

Precautions

Thank you for purchasing the chromatography column produced by Haohan

Each chromatographic column provided by Haohan has been aged, and for the analysis and separation effect you have obtained, please age it for another 1-2 hours before use. When aging, the carrier gas should be introduced for about 10 minutes first, and after the air inside the column is completely replaced, the temperature should be raised to the operating temperature using a program for aging.

To avoid contamination of the detector, please do not connect the chromatography column to the detector during aging.

When the temperature of the column box is higher than room temperature, a small amount of oxygen in the carrier gas will damage the stationary phase inside the chromatographic column. The carrier gas must be further deoxygenated using a deoxygenation tube (it is recommended that the oxygen content in the carrier gas used should not exceed 1PPm)

When installing the chromatography column, the product brand should face the operator, with the injection port (or see identification) on the left side of the column.

When disassembling the chromatographic column, first lower the column temperature to room temperature, and then turn off the carrier gas.