Workplace air toxic substance - determination of acetic anhydride - chromatographic column Detailed information:
Name: Filler Column
Fixed phase: porous polymer support of 2,6-diphenyl-p-phenylether
Specification: 2m * 4mm
Material: Glass Column/Stainless Steel
Model: Tenax
Application:
GBZ/T 160.60-2004 Determination of Toxic Substances in Workplace Air - Anhydride Compounds
GBZ/T 300.118-2017 Determination of Toxic Substances in Workplace Air Part 118: Acetic Anhydride, Maleic Anhydride, and Phthalic Anhydride
Suitable for:
Agilent 490 online/portable, 48905890689088608890
Shimadzu GC-14C, GC-2010, GC-2014, GC-2030
Thermo Fisher Scientific 1310130016101600
Varian 3800 Series
Brooke PE580590680690
Panno A90, Fuli GC9790, Huaai, Tianrui, Tianmei, GC7900, Chuanyi, Beifen Ruili, Dongxi Electronics, Lunan Ruihong, Jiedao/Kexiao
Haohan Chromatography (Shandong) Application Technology Development Co., Ltd., research and production《Workplace air toxic substance - determination of acetic anhydride - chromatographic column 》In Agilent, Shimadzu, Thermo Fisher, Varian, Brooke, PE, The separation is good and the effect is satisfactory.






Each chromatographic column undergoes rigorous testing
Complete range of chromatographic column types
Technical Support
Years of accumulated rich experience and technical team in chromatographic analysis
Using high-quality stainless steel tubes, glass tubes, and chromatographic fillers to produce various packed chromatographic columns
If you need to use stainless steel filter mesh as the plug at both ends of the column, please indicate it when ordering
If a column is used for sampling, there will be a space of 6CM at the front end of the column entrance,
To prevent the chromatographic packing from flowing out, both ends of the column are sealed with silanized glass wool
If a chromatographic column with valve injection or non column injection is used, the inlet of the column is filled
Can provide glass column configurations for various models of gas chromatographs
The inlet of the 2mm inner diameter glass column tube is equipped with a sloping surface for sample injection
Each chromatographic column undergoes thorough aging and rigorous quality evaluation testing
Precautions
Thank you for purchasing the chromatography column produced by Haohan
Each chromatographic column provided by Haohan has been aged, and for the analysis and separation effect you have obtained, please age it for another 1-2 hours before use. When aging, the carrier gas should be introduced for about 10 minutes first, and after the air inside the column is completely replaced, the temperature should be raised to the operating temperature using a program for aging.
To avoid contamination of the detector, please do not connect the chromatography column to the detector during aging.
When the temperature of the column box is higher than room temperature, a small amount of oxygen in the carrier gas will damage the stationary phase inside the chromatographic column. The carrier gas must be further deoxygenated using a deoxygenation tube (it is recommended that the oxygen content in the carrier gas used should not exceed 1PPm)
When installing the chromatography column, the product brand should face the operator, with the injection port (or see identification) on the left side of the column.
When disassembling the chromatographic column, first lower the column temperature to room temperature, and then turn off the carrier gas.