- Phone
-
Address
3rd Floor, E-commerce Building, No. 906 Meilong Avenue, Songhe Community, Longhua Street, Longhua District, Shenzhen
Shenzhen Kyoto Yuqi Electronics Co., Ltd
3rd Floor, E-commerce Building, No. 906 Meilong Avenue, Songhe Community, Longhua Street, Longhua District, Shenzhen
Wind speed of 0.001 m/s instead of anemometer SONIC Sonic
Wind speed of 0.001 m/s instead of anemometer SONIC Sonic
Measurement method: Time division transmission and reception switching ultrasonic pulse mode
Calculation method: reciprocal difference calculation method of ultrasonic propagation time
Measurement range:
Wind speed: 0-10 m/s
Acoustic virtual temperature: -30 to+50 ℃
Measurement accuracy:
Wind speed: ± (10% of measured value+0.05 m/s) * ¹, * ²
Wind direction: ± 10 ° * ¹, * ²
Acoustic virtual temperature: ± 5 ℃ (when there is no wind)
Output resolution:
Wind speed: 0.001 m/s
Acoustic virtual temperature: 0.01 ℃
Calculation cycle: 10 times/second
Responsiveness: Less than 5 seconds
Digital output:
Output format: RS-422 (converted to USB through a matching cable)
通信速率: 9600 bps
Output rate: 10 times/second
Data format: ASCII 6 bytes/measured component
Output data: A, B, C, T+³
Usage environment:
WAM-100 host: 0~+50 ℃, 20~80% RH
Probe: -30~+50 ℃, 20-80% RH
(All devices must not condense; there should be no obstacles such as water droplets or ice on the probe head)
Power supply: DC 12V/0.5A (DC 9.6-17V)
Anemometer host: WAM-100 1 unit
Probe: TR-93T 1 unit
Connecting wire: JSC-18 (1.7m) 1 piece
AC adapter: ACADP-12 1 piece
3D airflow visualization software: WASP-007F 1 set
Probe installation bracket: 1 piece
Zero calibration cover: 1 set
Portable case: 1 unit
Measurement axis spacing: 2 cm
Measuring wind direction range: within ± 20 ° of the main wind direction
Measure wind speed components: A, B, C axes
Purpose: Indoor breeze observation, etc
Measurement accuracy: ± (10% of the measured value+0.05 m/s)
(Within the range of ± 20 ° of the main wind direction after zero point calibration)
Power switch: used for turning on/off the local power supply (I)/off (O)
Probe connector: used to connect TR-93T probes
POWER LED: displays the power on status of the device
Green constantly on: power on/normal power on
Red light on: Input voltage warning (power supply voltage drops by 10%)
Red light on: Abnormal input voltage (power supply voltage below rated value)
Extinguish: Power off/no power supply
Status LED: displays the measurement/communication status of the device
Green: Power on preheating
Green: Normal measurement
Green: Zero calibration (running during zero reset)
Extinguish: Measurement stopped
Red: Data missing
Red: Hardware error (cable not connected, device failure, etc.)
Red: Communication error
Zero reset switch: used for zero calibration after probe connection
After covering the probe with the zero calibration cover to form a windless state, press and hold the switch for more than 3 seconds, the STOP LED will flash green at high speed, and zero calibration will begin; After calibration is completed, the LED remains green and constantly on.
DC IN connector: used to connect AC adapter ACADP-12
Grounding terminal: used to connect the grounding wire (using screw: M2.6L4)
SYSTEM PORT-1 connector: used for connecting the host to the computer
Special connecting wire JSC-18 must be used, and the use of commercially available cables is strictly prohibited.
SYSTEM PORT-2 connector: used for connecting multiple WAM-100 hosts
(For multi machine connection matters, please consult our company)