White light illuminance meter for detecting black light flaw detection lamp
The white light illuminance meter LUYOR-560 can accurately measure the visible light illuminance leaked from ultraviolet flaw detection lamps, fluorescent lamps, and black light lamps, displayed in foot candles (fc) or Lux units.. Many illuminance meters on the market, when measuring the white light illuminance of flaw detection black lamps, have significant deviations between the measured data and the actual data, resulting in misjudgment that the white light of the black lamp exceeds the standard and is unqualified. In fact, these white light illuminance meters can only measure the illuminance of the environment and the illuminance of white light fixtures, and cannot detect the white light illuminance of black light fixtures used for flaw detection. The main reason is that under ultraviolet irradiation, the light shield of the illuminance sensor of the white light illuminance meter produces bright fluorescence, which causes the white light of the black light lamp to exceed the standard.
White light illuminance meter for detecting black light flaw detection lampasThe daily tool of NDT testing line is used to measure visible light intensity, ensuring the quality and reliability of testing. Measured in foot candles or lux units, the digital white light illuminance meter can measure visible light illuminance, displayed in foot candles (fc) or Lux units, and includes a fixed sensor specifically designed to measure visible light in the range of 400-760nm.
The LUYOR-560 white light illuminance meter sensor is equipped with a 400nm ultraviolet filter, which can effectively isolate the interference of ultraviolet rays on the sensor, thus accurately measuring the white light illuminance of the black light lamp.
Considering the harsh environment of the non-destructive testing industry, the sensor will soon be severely contaminated. The LUYOR-560 white light illuminance meter is designed with a replaceable ultraviolet filter. If the ultraviolet filter is contaminated or scratched, causing measurement errors in the illuminance meter, customers can directly replace the sensor's ultraviolet filter.
Product Features:
Photodiode sensor.
Complies with the 400-760 nm range specified in ASTM E2297.
Accuracy+/-5%, in compliance with NADCAP requirements.
Measure visible light illumination range from 0-2000 foot candles/0-20000 lux.
Adjustable digital display range: 20, 200&2000 foot candles or 200, 2000&20000 lux.