Where is the stock of the EDS3300 series pressure switch from Hedeke,Supplied by GuanglianHYDAC pressure switch, HYDAC sensor advantage supply, *, there are many in stock, the price is beautiful, buy with confidence and use with comfort!
The German HYDAC pressure switch EDS 3300 series product is a compact electronic pressure switch with integrated digital display, used for relative pressure measurement in the low pressure range. For this purpose, it is equipped with a ceramic measuring cell with a thick layer of DMS. This device has 1 or 2 switch outputs and a reversible analog output signal (4... 20 mA or 0 .. 10V)。
A special feature of the EDS 3300 is the ability to rotate the display screen on two axes. The device can be aligned at almost any random installation position, which means the additional cost of mechanical alignment adapters that are usually required is eliminated. The 4-character digital display screen can display pressure in units of bar, psi, or MPa. Users can choose between different units. Using this feature, the device will automatically scale the switch settings based on the new unit.
In addition, EDS 3300 can also comply with DESINA variants. The variant with pre rinse membrane is specifically developed for the following applications: the medium used may cause blockages, adhesives, or freezing in standard pressure connections. The main applications of EDS 3300 are in hydraulic, pneumatic, refrigeration, and air conditioning technologies. Other applications include processes where media is frequently replaced and any residue may cause mixing or contamination of the media.
1 or 2 PNP transistor switch outputs, each with a load of up to 1.2 A
Accuracy ± 1% FS
Optional reversible analog output (4... 20 mA/0... 10V)
4-digit display
Alignment can be achieved through the rotational ability on two axes
Choose to display values in bar, psi, or MPa
Easy to handle through key programming
The switch point and reset hysteresis can be adjusted independently of each other
Many useful additional features
Allocation options with diagnostic terminals and DESINA consistency function
Optional pre rinse diaphragm
Optional, VDMA compliant menu navigation (unit table VDMA 24574-1)
HYDAC pressure switchIt also belongs to a type of directional sensor with switch output. The measuring head of the Hedeke HYDAC pressure switch is generally composed of one electrode of the capacitor, while the other electrode is the object itself. When the object moves closer to the switch, the dielectric constant of the object and the nearby switch changes, causing the circuit connected to the measuring head to also change, thereby controlling the on and off of the switch. This type of inspection object that is close to the switch is not limited to metal conductors, but can also be insulated liquid or powder objects when inspecting lower dielectric constantsε When dealing with objects, the multi turn potentiometer (located at the back of the switch) can be adjusted clockwise to increase sensing sensitivity. Generally, adjusting the potentiometer causes the capacitive proximity switch to move in the direction of 0.7-0.8Sn
Advantages:
1. The socket is a circuit terminal that we frequently touch. If a leakage maintenance switch is used for the socket circuit, it ensures maximum human safety to the greatest extent possible! And the socket lines are divided into several routes, so if there is a problem with one route, the sockets on other circuits can still operate normally!
2. If there is any doubt about the lighting circuit, the table lamp or floor lamp we connect to the socket can still operate normally, without leaving the room pitch black, and providing convenience for the maintenance of the lighting circuit! Home decoration attention:
1. Do not use a leakage switch as the main switch. Once it is disconnected due to a certain leakage, the house will be pitch black, which is unlucky for maintenance and daily life;
2. Do not mix the lighting circuit with the socket circuit, as this will prevent the leakage switch of the socket circuit from tripping as soon as the leakage maintenance switch is turned on;
3. Reasonably arrange the load of the line and equip appropriate circuit breakers and residual current maintenance switches with circuit breakers;
4. Decoration should not touch the equipotential box and its circuits;
5. It should be determined that each socket must have a reliable grounding wire connected (the last hole of the three hole socket is grounded);
6. Some of the wire and pipe joints (buried in the wall) need to be sealed with sealant to prevent moisture or water leakage from the wall, which can cause poor insulation and electrical leakage;
7. Do not directly fill the bottom box of the discarded socket with cement or other materials (especially those with joints), it should be covered with an inspection cover plate. It really affects the use of gypsum board virtual cover (with reserved space inside) to avoid joint corrosion, which is also convenient for maintenance.
Where is the stock of the EDS3300 series pressure switch from Hedeke
Advantages of German Hedec pressure switch models:
EDS3316-2-06,0-000-F1
EDS3316-3-0016-000-F1
EDS3318-5-06,0-000-F1
EDS3346-1-0010-000-F1
EDS3346-1-0010-000-F1+ZBE06
EDS3346-1-0016-000-F1+ZBE06-02
EDS3346-2-0010-000-E1
EDS3346-2-0016-000-E1
EDS3346-2-0016-000-F1
EDS3346-2-0016-000-F1+ZBE06
EDS3346-2-06,0-000-F1
EDS3346-3-0001-000-F1
EDS3346-3-0010-000-F1
EDS3346-3-0016-000-F1
EDS3346-3-0016-000-F1
EDS3346-3-0016-000-F1+ZBE06
EDS3346-3-060-000-F1
EDS3348-5-0010-000-F1
EDS3348-5-0010-000-F1+ZBE08+ZBM14
EDS3348-5-0016-000-F1
EDS3348-5-0016-000-F1
EDS3348-5-06.0-000-F1