WZPB integrated thermistor

NegotiableUpdate on 05/10
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The thermoelectric potential (resistance value) generated by the WZPB integrated thermistor generates an unbalanced signal through the bridge of the temperature transmitter, which is amplified and converted into a 4-20mA DC electrical signal for the worker's instrument. The working instrument displays the corresponding temperature value.

Product Details

Characteristics of WZPB integrated thermistor:

Two line output 4-20mA, strong anti-interference ability;
Save the cost of compensating wires and installing temperature transmitters;
Safe and reliable, with a long service life;
Cold end temperature automatic compensation, non-linear correction circuit;

working principle
The change in thermoelectric potential (resistance) measured by a thermocouple (resistor) in working state generates an unbalanced signal through the bridge of the temperature transmitter, which is amplified and converted into a 4-20mA electrical signal to the working instrument. The working instrument then displays the corresponding temperature value.
Explosion proof thermocouple (resistor) utilizes the principle of gap explosion-proof. When an explosion occurs inside the chamber, it can extinguish and cool through the gap between the joint surfaces, preventing the flame and temperature after the explosion from being transmitted outside the chamber, thus enabling temperature measurement. The thermoelectric potential (resistance value) generated by the thermocouple (resistor) is amplified by the temperature transmitter's bridge to generate an unbalanced signal, which is then converted into a 4-20mA DC electrical signal and sent to the worker's instrument. The working instrument displays the corresponding temperature value.

WZPB integrated thermistorMain technical parameters:

Product execution standards
IEC584
IEC751
IEC1515
JB/T5518-91
JB/T7391-94
Measurement range and tolerance
1) Temperature measurement range and tolerance of thermistor

Model number Dividing number Temperature measurement range ℃ accuracy class allowable deviation
WZPB Pt100 -200-+500
*Grade B
±( 0.15 + 0.002 ITI )
±( 0.30 + 0.005 ITI )
WZCB Cu50 Cu100 -50-+100   ±( 0.30 + 0.005 ITI )
2) Thermocouple temperature measurement range and tolerance
Model number Dividing number Tolerance level
I II
Allowable deviation Temperature measurement range ℃ Allowable deviation Temperature measurement range
WRNB K ±1.5℃ -40-375 ±2.5℃ -40-333
± 0.004 ITI 375-1000 0.0075% smile 333-1200
WRMB N ±1.5℃ -40-375 ±2.5℃ -40-333
± 0.004 ITI 375-1000 0.0075% smile 333-1200
WREB E ±1.5℃ -40-375 ±1.5℃ -40-333
± 0.004 ITI 375-800 0.004% smile 333-900
WRFB J ±1.5℃ -40-375 ±1.5℃ -40-333
± 0.004 ITI 375-750 0.004% smile 333-750
WRCB T ±1.5℃ -40-125 ±1℃ -40-133
± 0.004 ITI 125-350 0.0075% smile 133-1000
Output signal: 4-20 mA, load resistance 250, transmission wire resistance 100
Output method: Two line system
Accuracy level:
Temperature transmitter accuracy level: 0.1 0.2 0.5
Display accuracy level: Analog indicator 2.5 level; Digital display level 0.5

Power supply: 24V DC ± 10 ℅
Protection level: IP65
Explosion proof grade:
Explosion proof type: d Ⅱ BT4 d Ⅱ CT5 d Ⅱ CT6
Intrinsic safety type: ia Ⅱ CT6
Insulation resistance: The insulation resistance between the instrument output terminal and the housing should not be less than 50
Thermal response time:
When there is a step change in temperature, the time required for the current output signal of the instrument to change to 50% of the step change is usually represented by t0.5. When the step response stabilization time of the temperature transmitter does not exceed one-fifth of the thermocouple (resistance) thermal response stabilization time t0.5, the thermocouple (resistance) thermal response time is used as the thermal response time of the instrument; When the step thermal response stability time of the temperature transmitter does not exceed half of the thermocouple (resistance) thermal response stability time t0.5, the thermal response time of the temperature transmitter is used as the thermal response time of the instrument;
Basic error:
The basic error of the instrument should not exceed the combined error of the basic errors of the thermocouple (resistor) and temperature transmitter