No. 20 Renhe Road, Tianchang City, Anhui Province
Anhui Kangrong Electric Co., Ltd
No. 20 Renhe Road, Tianchang City, Anhui Province
The WZ series industrial thermistor is used as a temperature measurement sensor, usually paired with temperature transmitters, regulators, and display instruments to form a process control system. It is used to directly measure or control the temperature of liquid, steam, gas media, and solid surfaces within the range of -200 ℃ to 500 ℃ in various production processes
Thermistor measures temperature by utilizing the characteristic that the resistance of a substance changes with temperature When there is a temperature gradient present in the measured medium, the measured temperature is the average temperature in the medium within the range of the temperature sensing element
Although there are significant differences in the appearance of various thermal resistors, their basic structures are generally similar, consisting mainly of temperature sensing elements, insulation sleeves, protective tubes, and junction boxes
Characteristics of WZP thermistor:
·Pressure spring type temperature sensing element with good anti vibration performance;
·High temperature measurement accuracy;
·High mechanical strength and good pressure resistance;
·Imported thin film resistor components with reliable and stable performance.
working principle
Thermistor measures temperature by utilizing the characteristic that the resistance of a substance changes with temperature. When the resistance value changes, the working instrument displays the temperature value corresponding to the resistance value.
WZP thermistorTechnical Specifications
Product execution standards
IEC584
IEC1515
GB/T16839-1997
JB/T5582-91
Room temperature insulation resistance
The thermal resistance is tested at an ambient temperature of 15-35 ° C, relative humidity not exceeding 80%, and a test voltage of 10-100V (DC). The insulation resistance between the electrode and the outer sleeve is greater than 100M Ω.
Measure temperature and tolerance
| Model number | Dividing number | Temperature measurement range | accuracy class | allowable error |
| WZP | Pt100 | -200-+500 | Alevel | ±(0.15+0.002) ltl |
| Blevel | ±(0.30+0.005) ltl | |||
| WZC | Cu50 Cu100 | -50-+100 | --- | ±(0.30+0.005) ltl |
![]() |