The WZ-L-IHG1 oxygen analyzer consists of a converter and a detector. The detector adopts a direct insertion probe structure, which does not require a sampling system and can timely reflect the combustion status inside the boiler. If used in conjunction with an automatic control device, it can effectively control the combustion status. It is widely used in sulfuric acid manufacturing systems, such as power, metallurgy, heating, building materials, electronics, etc. It analyzes the oxygen content of flue gas in various industrial boilers and kilns, improves combustion efficiency, saves energy, and reduces environmental pollution.
WZ-L-IHG1 Oxygen AnalyzerComposed of a converter and a detector, the detector adopts a direct insertion probe structure, does not require a sampling system, and can timely reflect the combustion status inside the boiler. If used in conjunction with an automatic control device, it can effectively control the combustion status and is applied in sulfuric acid manufacturing systems
Scope of use:WZ-L-IHG1 Oxygen Analyzer
Widely used in power, metallurgy, heating, building materials, electronics and other sectors, analyzing the oxygen content of flue gas in various industrial boilers and kilns, improving combustion efficiency, saving energy, and reducing environmental pollution.
Production workshop:



Packaging and shipping:


On site use:




Main features:
- Large screen LCD display screen
- Full Chinese operation menu
- Real time clock display
- Can be connected to a printer to achieve timed automatic printing
- Equipped with timed automatic storage function and the ability to view stored data at any time
- Equipped with a paperless recorder function, it automatically records the curve of oxygen concentration changes over time
- Equipped with RS232 communication port, it can be connected to a computer to achieve real-time data transmission, data storage, curve trend chart, printing report and other functions
- Can set upper and lower limit alarm points, with alarm contact output
- Online calibration with available standard gas
- Optional output current of 0-10mA or 4-20mA
Technical indicators:
- Measurement range: 0-5, 10, 25%, 50% O2(Three significant digits)
- Accuracy: ± 2%
- Linearity: ± 1% of the measuring range (analog output)
- Repeatability: ± 0.5% of the measuring range (analog output)
- Stability: ± 2%/7d of range (zero range full range)
- Load resistance: 0-1.6k Ω (0-10mA); 0~800Ω(4~20mA)
- Power consumption:<80W
- Power supply: 220V ± 10%
- Environmental temperature: Converter: 0-40 ℃; Detector: -10~80 ℃
- Sample gas temperature: 0-700 ℃
- Sample gas pressure range: -500~500mmH2O
- Response time: ≤ 5s (up to 90% of measured value)
- Detector length: 0.4m; 0.8m; 1.0m;1.2m
|
|