The SWP-MD806 digital display instrument is integrated with an analog instrument, which can perform digital display control (high brightness LED digital display) on measurement signals such as temperature, pressure, liquid level, and speed, making the display of measurement values clearer and more intuitive. Product Description: Intelligent Instrument SWP-C801-00 SWP-C80 SWP-C90 SWP-0 SWP-C70 SWP-C10 SWP-C803-02-12-HL-P Series Intelligent Digital Display Meter Main Features

Product Details

SWP-MD806 Digital Display Instrument
wiring diagram
SWP-C801/SWP-C803 series and SWP-S801/SWP-S803 series digital display meter wiring diagram:
Wiring diagram for SWP-01/SWP-03 series and SWP-S401/SWP-S403 series digital display meters:
SWP-C901/C903 series digital display meter wiring diagram:
SWP-C701/SWP-C703 series digital display meter wiring diagram:

SWP-C101/SWP-C103 series intelligent digital display meter wiring diagram:

Selection Table for SWP-C80/SWP-C90/SWP-0/SWP-C70/SWP-C10 Series Intelligent Digital Display Instruments
Model number Code Explanation
SWP- Intelligent Instrument SWP-C803-01
Appearance characteristics
C
S
Horizontal digital display instrument
Vertical digital display instrument
Overall dimensions
1
4
7
8
9
48×48mm
96 × 48mm (horizontal), 48 × 96mm (vertical)
72×72mm
160 × 80mm (horizontal), 80 × 160mm (vertical)
96×96mm
Control function
01
03
04
Measurement display table
Three position control table (display)+Upper and lower limit alarms
Four limit control or four limit alarm meter (display)+Four alarm outputs)
contact method Refer to "Communication Methods"
output method Refer to 'Output Method'
input type Refer to 'Input Types'
*Alarm method
N
H
L
No alarm (can be omitted)
Upper limit control/alarm (four limit control/alarm 2H)
Lower limit control/alarm (2L for four limit control/alarm)
Second alarm method
N
H
L
No alarm (can be omitted)
Upper limit control/alarm (four limit control/alarm 2H)
Lower limit control/alarm (2L for four limit control/alarm)
power feed output P DC24V power supply output
power supply method
W
T
DC24V power supply
AC90-265V power supply (switch mode power supply)
AC220V power supply (linear power supply, can be omitted)
Instrument input type
code input type measurement range code Input type measurement range code input type measurement range
01 B 400~1800 ℃ 09 Pt100.1 -99.9~199.9℃ 17 30-350Ω -1999~99999d
02 S 0 ~1600 ℃ 10 Cu50 -50.0~150.0 ℃ 18 Special specifications User specific
03 K 0 ~1300 ℃ 11 Cu100 -50.0~150.0 ℃ 19 4-20mA square meter -1999~99999d
04 E 0 ~1000 ℃ 12 4~20mA -1999~99999 d 20 0-10m square meter -1999~99999d
05 T -200~400 ℃ 13 0~10mA -1999~99999 d 21 1-5V square root -1999~99999d
06 J 0 ~1200 ℃ 14 1~5V -1999~99999 d 22 0-5V square root -1999~99999d
07 Wre 0 ~2300 ℃ 15 0~5V -1999~99999 d 23 Switchable input Please refer to the table below for details
08 Pt100 -200~650 ℃ 16 0~20mA -1999~99999 d 24 Frequency input 0~5kHz
To fully switch inputs, simply set the secondary parameters of the instrument to switch between multiple division marks. The division marks that can be input are as follows:
code input type code input type code input type code input type code input type
01 B 05 T 09 Pt100.1 14 1~5 V 18 1-5V square root
02 S 06 J 10 Cu50 15 0~5 V 19 0-5V square root
03 K 07 WRe 12 4~20 mA 16 4-20 mA square root     
04 E 08 Pt100 13 0~10 mA 17 0-10mA square root    
Transmission output mode
Selection code 0 1 2 3 4 5 8
output method No output alarm output
Transmission output 4-20mA
Alarm with relay
Transmission output 0-10mA
Alarm with relay
Transmission output 1-5V
Alarm with relay
Transmission output 0-5V
Alarm with relay
Special specifications
contact method
Selection code 0 2 4 8 9
contact method No communication RS-232 RS-422 RS-485 Special specifications
Note 1: The SWP-C801 and SWP-C803 series are 0.8-inch LED displays, SWP-C901、SWP-C903、SWP-S801、SWP-S803、SWP-C701、
The SWP-C703, SWP-01, and SWP-03 series have 0.56-inch LED displays, while the SWP-C101/C101 series have 0.32-inch LED displays.
Note 2: The four limit control or four limit alarm output is controlled by four relays, and users can modify internal parameters to set the desired control or alarm mode.
(Four limit control/alarm is only available for SWP-C804/S804 and C904 series, 2H represents two upper limit control/alarm, 2L represents two lower limit control/alarm).
Note 3: For the same division number, the selection code and instrument programming code are different. Please pay attention when setting the instrument.
Note 4: SWP-C701/SWP-C703 and SWP-C101/SWP-C103 have no frequency signal input.
Model example: Intelligent instrument SWP-C803-01
例1、 SWP-C801-00-23-N-P
Display instrument, without communication and transmission output, 4-20mA (universal) input, with DC24V output fed, the instrument has an appearance of 160 × 80mm
例2、 SWP-C801-02-03-N
Measurement shows that the instrument has no communication, the transmission output is 4-20mA, the K division mark (universal) input, the instrument is powered by AC220V, and the instrument has a vertical shape of 160 × 80mm
Example 3: SWP-C803-01-23-HL
Measurement display+alarm, instrument without communication and transmission output, Pt100 (universal) input, with upper and lower limit alarm/control output, powered by AC220V outside the instrument,
The instrument has a horizontal shape of 160 × 80mm.
Example 4: SWP-C803-02-12-HL-P
Measurement display+alarm, instrument no communication, transmission output 4-20mA, Pt100 (universal) input, with upper and lower limit alarm/control output, with feeding DC24V output,
The instrument is powered by AC220V and has a horizontal shape of 160 × 80mm.
Example of incorrect model: SWP-C801-02-12-HL-P
Reason for selection error: The SWP-C801 display instrument does not have an alarm function (code in the model: HL)
Example of correct model: SWP-C803-02-12-HL-P