Shanghai Xuanxu specializes in productionWRPC-430/WRNC-430 Blowing Thermocouple
The blowing thermocouple is a temperature measuring device in a 300000 ton synthetic ammonia plant. It improves the lifespan of thermocouples by blowing in nitrogen or other gases to remove harmful gases from the protective tube, and is widely used in some refining units.
Working principle of blowing thermocouple
The structural principle of the blowing thermocouple is to form a certain gas path between the temperature sensing element of the armored thermocouple and the outer protective tube. In the gas path, a certain pressure of inert gas is introduced to eliminate or reduce the infiltration of trace tantalum elements into the thermocouple under high temperature and high pressure conditions, which increases the suction characteristics of the blowing thermocouple and extends the service life of the armored thermocouple. The key temperature sensor used for the complete set of ammonia synthesis equipment.
Classification of blowing thermocouples
There are three types of blowing thermocouples: blowing flow type, blowing positive pressure type, and no blowing type. Non blowing type is suitable for temperatures below 1200 ℃, and it is recommended to install vertically. By blowing in nitrogen or other gases, harmful gases are sent out of the protective tube, thereby increasing the lifespan of the thermocouple, which is about 12-24 months. It has been widely used in refining and chemical facilities such as Guangzhou Petrochemical, Shanghai Petrochemical, Datang Duolun Coal Chemical, Shanghai Gaoqiao Petrochemical, Zhanjiang Petrochemical, Jilin Refinery, etc.
Technical parameters of blowing thermocouple
1. Electrical export: M20X1.5, NPT1/2
2. Accuracy level: III
3. Protection level: IP65
4. Nominal pressure: atmospheric pressure
Model and specifications of blowing thermocouple
type number |
divide degree number |
Temperature measurement range℃ |
flow fast |
rule grid |
|
|
WRPC-430 WRP2C-430 |
S K |
0-1300 |
GH3039 High alumina
|
d |
LX1 |
¢2.5 |
900X750 1000X850 1150X1000 |
||||
1) thermocoupleIOrder according to the agreement;
2) Order the remaining materials of the protective tube according to the agreement;
Thank you for your interest in Xuanxu Electric's products. If you would like to gain further understanding, such asWRPC-430/WRNC-430 Blowing ThermocouplePriceFor more information on specifications, models, installation and usage methods, please feel free to contact us at any time. We sincerely invite you to provide us with the most satisfactory service!