SCP shielded wire cable thermocouple connection compensation wire

NegotiableUpdate on 05/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Shanghai Xuanxu SCP shielded wire and cable thermocouple connection compensation wire insulation material: polyvinyl chloride insulation and sheath copper wire braided shielding is generally used for precision S-grade thermocouple shielding compensation wire, conductor material: polyvinyl chloride insulation color: positive electrode is red and negative electrode is black. This product is mainly used as a connecting wire for automation measuring instruments in industries such as power, chemical, petroleum, metallurgy, textile, and national defense.

Product Details

SCP shielded wire cable thermocouple connection compensation wire full name: PVC insulated and sheathed copper wire braided shielding is generally used for precision S-grade thermocouple shielding compensation wire.

Insulation material for compensating wires with shielded wires and cables, thermocouple connections, and compensation wires: polyvinyl chloride. Insulation color: positive electrode is red and negative electrode is black

Conductor material: positive electrode is nickel chromium - negative electrode is nickel silicon thermocouple with division number K

Shielding material: Copper wire braided

Sheath material: F46 Sheath color: gray Temperature: -20~260 degrees.

Polyethylene (Y) insulation and cross-linked polyethylene (YJ) insulation compensation cables can be provided as needed.

Insulation resistance: 25M Ω· km

Voltage test: 1000 V/1min

Flame retardant performance: meets the requirements of Class A, B, and C in the GB/T18380-2001 flame retardant standard

Thermoelectric potential and tolerance: Precision grade 8137 ± 60 (± 1.5 ℃)

Specifications

specification

A-class conductor

R-class conductor

Reciprocating resistance value at 20 ℃ ≤ Ω/m

2×0.5 mm²

1/0.80

7/0.30

2.20

2×1.0 mm²

1/1.13

7/0.43

1.10

2×1.5 mm²

1/1.37

7/0.52

0.73

2×2.5 mm²

1/1.76

19/0.41

0.44

When the conductor is a multi strand soft core, "R" should be added after the prototype number

In the old standard GB4989-85, ordinary grade is represented by B, and precision grade is represented by A

Flame retardant compensating cables should have "ZR" added before the prototype number-

Armor type, "-22" should be added after the prototype number to indicate steel belt armor; Add "-32" to indicate steel wire armor.