- Phone
-
Address
906, Building 1, Yuzhou City Plaza, Lane 49, Chuanshan Street, Pudong New Area, Shanghai
Shanghai Taoshi Industrial Development Co., Ltd
906, Building 1, Yuzhou City Plaza, Lane 49, Chuanshan Street, Pudong New Area, Shanghai
Volkswagen Digital Valve Positioner3821-37MA-D41R-1110-00 is an intelligent digital valve positioner of the Flowserve Logix 3800 series, used for precise control of pneumatic actuators and widely used in industrial fields such as petroleum, chemical, and power.
1、 Model code analysis
3821: Main model (Logix 3800 series)
37MA: Configuration code (communication/output/feedback type)
D41R: Explosion proof/Protective/Electrical Interface
1110-00: Special Options/Versions
2、 Core technical parameters
Control signal: 4-20mA DC (standard)
Feedback type: Non contact magnetic/Hall sensor
Accuracy: ± 0.5% (optional ± 0.1%)
Return difference: ≤ 0.5%
Gas source pressure: 1.4-10.3 bar
Output pressure: 0-100% supply pressure
Protection level: IP66/NEMA 4X
Explosion proof certification: ATEX, IECEx (optional)
Communication protocols: HART, FF, Profibus
Temperature range: -40 ℃ to+85 ℃
Shell material: Aluminum alloy
Volkswagen Digital Valve Positioner
3、 Main functions and features
Intelligent automatic calibration: One click automatic calibration of stroke, zero position, and range
Non contact feedback: no wear, long lifespan, anti vibration
HART communication: remote monitoring, parameter setting, diagnosis
Double acting/single acting: supports gas on/off, positive and negative effects
Fault diagnosis: valve jamming, leakage, abnormal gas supply alarm
Low power consumption:<0.15 m ³/h air consumption
4、 Typical applications
Petrochemical industry: regulating valves, shut-off valves, emergency shut-off valves
Electricity: boiler feedwater, steam, flue gas desulfurization system
Water treatment: flow/pressure/liquid level control
Metallurgy: blast furnace, heating furnace, flue gas system
5、 Quick debugging steps
Manual automatic switching: Long press and hold the STOP button for 3 seconds → OUT OF Service
Automatic tuning: FUNC → CALIBRATE → AUTOCAL → START TUNE
Parameter settings:
Current range: 0%=4mA/100%=20mA
Mode of action: Air on/off, positive and negative effects
Restore Automatic: Status → In Service
6、 Common faults and solutions
No display: Check 24V power supply, fuse, power board
No action: air source pressure, signal wiring, actuator jamming
Inaccurate positioning: Automatically recalibrate and check feedback sensors
Communication abnormality: Check the HART wiring, baud rate, and address