1. Introduction
Vibration speed sensors, also known as magneto electric vibration speed sensors, are mainly installed on the bearing covers of various rotating mechanical devices, such as steam turbines, compressors, fans, and pumps. It is an electromagnetic sensor that outputs voltage by cutting magnetic field lines with a moving coil, and therefore has the characteristics of not requiring power supply during operation and easy installation.
2. Technical parameters
Sensitivity: 50mv/mms-1
● Frequency response (optional):
a. 5~100 Hz
b. 10~500 Hz
c. 10~1000 Hz
● Natural frequency: 10Hz
Measurable amplitude: ≤ 2000 μ m (P-P)
● Maximum acceleration: 10g
Measurement direction: vertical or horizontal
● Operating environment: Temperature range of -30 ℃ to 100 ℃
Relative humidity ≤ 90%
● Dimensions: φ 35 × 78mm
Weight: Approximately 350g
Installation thread: M10 × 1.5
Can be designed and produced according to user requirements
Main products: ZT6101 intelligent speed monitoring instrument, ZT6201 axial displacement monitoring instrument, ZT6202 differential expansion monitoring instrument, ZT6301 shaft vibration monitoring instrument, ZT6302 vibration monitoring instrument, ZT6303 eccentricity monitoring instrument, ZT6303 eccentricity monitoring instrument, ZT6501 thermal expansion stroke monitoring instrument, ZT6502 hydraulic engine stroke monitoring instrument, ZT6503 oil tank level monitoring instrument, ZT6800 series steam turbine monitoring system, CZ-01 reluctance speed sensor, HE-01 Hall speed sensor, DO-02 eddy current sensorCD-6 vibration speed sensor、 TD-1 hydraulic engine sensor, UT-81 series oil tank level sensor, ZT-B10 speed transmitter, ZT-B20 stroke transmitter, ZT-B30 axial displacement (differential expansion) transmitter, ZT-B40 bearing vibration transmitter, ZT-YB40 integrated vibration transmitter, ZT-WB series temperature transmitter, ETS system ETS system, eddy current debugging rack
Vibration sensor CD-6
2、 Outline diagram

picture1.Outline drawing
three、Installation position: vertically or horizontally installed on the tested vibration point, at the bottomM10×1.5screwfixedOn the tested shell, then screw the sensor onto it and tighten it.
1. Install the sensor on the vibrating object to be tested. When installing vertically, the sensor axis should be installed along the direction of the ground perpendicular at the location of the vibration to be measured, and the base should be at the bottom, the aviation socket should be at the top, and it cannot be installed upside down. When installing horizontally, the sensor axis should be placed in a horizontal plane (lying down) and aligned with the direction of the vibration to be measured,