Introduction: Vibration rod level switch Overview: The vibration rod level switch is suitable for fixed-point alarm or control of various material levels in silos and liquid levels in containers, and can detect sediment in liquids! The instrument has no movable parts and features anti-corrosion, high sensitivity, and easy installation
Overview of vibrating rod level switch:
The vibrating rod level switch is suitable for fixed-point alarm or control of various material levels in silos and liquid levels in containers, and can detect sediment in liquids! The instrument has no movable parts and is corrosion-resistant with high sensitivity
And features such as easy installation. Solid materials: rice, milk powder, sugar, salt, laundry detergent, cement, stone powder, plastic pellets, etc; Liquid media: water, mud, pulp, dyes, oils, milk, alcohol, beverages, etc
Working principle of vibrating rod level switch
The vibrating rod level switch utilizes the "resonance" principle of a tuning fork. The vibrating tube and the built-in vibrating rod form a "tuning fork" resonance probe with a frequency of 280Hz, which vibrates under the drive of piezoelectric elements. When the probe
When the measured object is touched, the amplitude of the vibration decreases and is converted into an electronic signal, causing the relay switch to operate.
Technical parameters of vibrating rod level switch:
Environmental temperature: -25~600C
Working temperature in the container: -20~1200C (please specify the working temperature when ordering)
Vibration rod material: aluminum alloy or stainless steel (customizable by users)
Vibration frequency of the vibrating rod: about 200Hz
Power supply voltage: AC220V DC24V
Damping delay of vibration rod: about 2s
Power: 15W
Free delay of vibration rod: about 7s
Output signal: DPDT 0/10mA
The medium is a non viscous material and does not contain any objects that corrode the vibrating rod
Export line: M18 * 15
Protection level: IP65
Contact capacity: AC220V 5A
Explosion proof: Solid DIP DT13 dust explosion-proof (not applicable to explosive sites)
Material particles * * Large external dimensions: ≤ 10mm
Liquid: dIIBT4
Large pressure resistance in container: 4.0MPa (pressure resistance should be specified when ordering)
Electrical connection of vibrating rod level switch
After connecting the power supply, the device enters normal operation with a 5-second delay. When the upper limit alarm is triggered, the limit will be activated
Select to dial up, and when the lower limit alarm occurs, select to dial down the limit.
Turn the sensitivity selection to the top for high sensitivity and to the bottom for low sensitivity.
Sensitivity adjustment: counterclockwise direction increases sensitivity, clockwise direction decreases sensitivity.