Vanquish PSeries electric fog detector
Take your productivity to new heightsVanquish LCAdvantages of the platform
•Provide reliable universal testing to meet your application needs
•High detector sensitivity and low baseline noise
•Advanced evaporation temperature control and introduction of diversion valves to enhance robustness
• Thermo Scientific™ Vanquish™ LCThe integrated detector in the system optimizes laboratory space utilization and seamlessly integrates into existing workflows
•passThermo Scientific™ Vanquish™Anti gradientLCThe system achieves consistency in response factors, and even in gradient methods, a single calibration substance can be used for quantification
• Thermo Scientific™ Vanquish™User touch screen can instantly monitor detectors and system parameters, and is built-instep by stepThe maintenance video
Reliable analysis
Using a liquid chromatography detector alone cannot achieve perfect results. Often, there are situations where the response of one type of analyte is stronger than another or where one type of analyte does not respond at all. Therefore, you need to use detection instruments with as consistent a response as possible to help you overcome difficulties, and electric fog detectors are the ideal solution. The electric fog detector has a stable response and can achieve accurate quantification and reliable analysis.
Unlike mass spectrometers and ultraviolet detectors, electrospray detectors are capable of detecting all analytes in a sample(image1)When using a mass spectrometer, the analyte needs to form gaseous ions, and the response of the UV detector depends on the intensity of the chromophore.
The abnormally stable consistent response of the electrospray detector supports the quantification of multiple analytes using a single calibration substance--Suitable for determining the concentration of unknown compound impurities when there is a lack of standard samples or when the cost of standard samples is too high. image 2Displaying various physical and chemical properties 22 A non-volatile analyte with a relative response deviation of only7.2%.
Thermo Scientific™VanquishElectric fog detectorPThe series response is consistent and can detect all non-volatile and mostly semi volatile analytes. It has a wide range of uses It can be used to analyze drugs, biomolecules, food and beverage, specialty chemicals, polymers, etc. It can provide you with the accuracy required for research and development, as well as productionQA/QCThe required reproducibility.
After using an electric mist detector, reliable and accurate analysis results can be obtained for each sample.
Simple three-step operation
Obtain reliable results
· Higher sensitivity than other general detectors 10 times
The electric fog detector has a linear response of up to two orders of magnitude and a dynamic range of four orders of magnitude, and its sensitivity is higher than that of the differential refractive index detector and the evaporative light scattering detector.
· Measure particle charge rather than mass or optical activity
The electrospray detector can measure particle charge, and the signal is proportional to the amount of analyte in the sample.
· Compatible with gradient elution
Different from differential refractive index detector,Electric fog detector compatible with gradient elution,Can achieve better separation, faster analysis, and higher peak separation.