Valve opening display table WP-D935 operator: It can automatically follow the input value to adjust the control output, and can have one analog control output, one switch control output (can control forward/reverse), and one analog tracking output. Can achieve automatic/manual undisturbed switching. When manually switching to automatic mode, an approximation algorithm is used with a switching limit function to ensure smooth switching between manual and automatic modes.
Valve opening display tableProduct Description: How to Translate
The intelligent manual operator uses a microprocessor for intelligent control and can be connected to various regulators as a backup control instrument. Once the regulator control fails, it can be manually operated and controlled by this controller, and can replace the servo amplifier to directly drive the electric or pneumatic actuator. It can simultaneously input and display measurement signals and feedback signals. And the input port has signal input function, which can easily switch between different types of input signals (various thermocouples, thermistors, standard signals) through simple selection in the instrument menu, improving the universality and reliability of the instrument.
Adopting high brightness LED digital display and high-resolution light column display (proportional display), clear and intuitive. There are two display modes: dual screen digital display; Dual screen digital display+dual light column display (displaying measured values+valve position feedback values/output values). The input/output circuits are both optically isolated and can be equipped with serial communication interfaces.
Valve opening display tableSelection Table:
| model | Instructions |
| WP- | □ | □ | □□ | □ | □ | □ | □ | □ | □ | □ | □ | □ | □□ | □ | |
| appearance feature | D | | | | | | | | | | | | | | Dual screen horizontal digital display |
| S | | | | | | | | | | | | | | Dual screen vertical digital display |
| T | | | | | | | | | | | | | | Vertical dual screen dual light column display |
| TX | | | | | | | | | | | | | | Horizontal dual screen dual light column display |
| Overall dimensions | 4 | | | | | | | | | | | | | 96 × 48mm (horizontal); 48 × 96mm (vertical) |
| 8 | | | | | | | | | | | | | 160 × 80mm (horizontal); 80 × 160mm (vertical) |
| 9 | | | | | | | | | | | | | 96 × 96mm (Method) |
| control function | 35 | | | | | | | | | | | | Operation controller |
| contact method | 0 | | | | | | | | | | | No communication interface |
| 2 | | | | | | | | | | | RS-232C communication interface |
| 8 | | | | | | | | | | | RS-485 communication interface |
| Operation signal output (SVout) | 1 | | | | | | | | | | Relay forward and reverse control output (D-type) |
| 2 | | | | | | | | | | (4-20) mA output (Q-type) |
| 3 | | | | | | | | | | (0-10) mA output (Q-type) |
| 4 | | | | | | | | | | (1-5) V output (Q-type) |
| 5 | | | | | | | | | | (0-5) V output (Q-type) |
| 6 | | | | | | | | | | Controllable silicon forward and reverse zero crossing control output (D-type) |
| 7 | | | | | | | | | | SSR Solid State Relay Control Output Signal (D-type) |
| 8 | | | | | | | | | | Special specification operation signal output |
| Feedback or Measurement Transmission Output (PVout) | 0 | | | | | | | | | No transmission output |
| 2 | | | | | | | | | (4-20) mA output |
| 3 | | | | | | | | | (0-10) mA output |
| 4 | | | | | | | | | (1-5) V output |
| 5 | | | | | | | | | (0-5) V output |
| PV input code | □ | | | | | | | | Refer to the 'Input Type Table' | The factory setting is based on the division number ordered by the user, and if there is no requirement, it defaults to '12' |
| SV input code | □ | | | | | | | Input types 12-16 in the table |
| Feedback or measurement value alarm method | H | | | | | | upper limit alarm | This function cannot be omitted |
| L | | | | | | lower limit alarm |
| Status signal DO output | R | | | | | relay | (Hand/Auto Switching Contact Signal) Without this function, it can be omitted |
| T | | | | | TTL level |
| Fault or external DI input | M | | | | External input (forced manual function) (can be omitted if this function is not available) |
| Remote key control | B | | | Equivalent to panel key input (can be omitted without this function) |
| Feed output | P | | One DC24V power supply output | This function cannot be omitted |
| 2P | | Two DC24V power supply outputs |
| power supply method | T | AC (90-265) V switching power supply |
| W | DC 24V power supply |
Example 1: Technical requirements:
1. The instrument is a backup instrument for the DCS system; 2. DCS system regulation signal is 0-10mA; 3. actuator drive signal is 4-20mA; 4. actuator feedback signal is 4-20mA; 5. DCS system receives 1-5V monitoring signal; 6. DCS system receives manual and automatic status signals; 7. DCS system output fault signal; 8. The system requires 485 communication; 9. The instrument has two dual screen displays with dimensions of 160 × 80 and 96 × 96.
Input type table:
| code | input type | measurement range | code | input type | measurement range | code | input type | measurement range |
| 01 | B | 400~1800℃ | 09 | Pt100.1 | -99.9~320.0℃ | 17 | (30~350)Ω | -1999~9999d |
| 02 | S | 0~1600℃ | 10 | Cu50 | -50.0~150.0℃ | 18 | Special specifications | Specific (note)1) |
| 03 | K | 0~1300℃ | 11 | (0~20)mV | -1999~9999d | 19 | (4~20)mAroot extraction | -1999~9999d |
| 04 | E | 0~1000℃ | 12 | (4~20)mA | -1999~9999d | 20 | (0~10)mAroot extraction | -1999~9999d |
| 05 | T | 0~320.0℃ | 13 | (0~10)mA | -1999~9999d | 21 | (1~5)Vroot extraction | -1999~9999d |
| 06 | J | 0~1200℃ | 14 | (1~5)V | -1999~9999d | 22 | (0~5)Vroot extraction | -1999~9999d |
| 07 | WRe3-25 | 0~2300℃ | 15 | (0~5)V | -1999~9999d | 23 | Switchable input | note2(Excluding)17Code input) |
| 08 | Pt100 | -200~650℃ | 16 | (0~20)mA | -1999~9999d | | |
Note 1: For special models or requirements, please specify the input signal type or reference standard when placing an order.
Note 2: The switchable input only requires setting the secondary parameters of the instrument, and the following input division marks can be switched.