Product Description
Targeting domestic and international high-tech, adopting large-scale integrated circuit and microcontroller technology. This instrument has multifunctionality and can be used as both a tachometer and a vibration test, especially with all the functions of measuring dynamic balance. The instrument is easy to operate, with human-machine dialogue, menu prompts, and measurement data can be locked and maintained at any time. It is equipped with dual power supply of internal battery and mains power, making it convenient for on-site dynamic balance testing of rotating machinery. It can also be matched with a balancing machine and directly replace the balancing machine box for the renovation of old balancing machines.
VT700 on-site dynamic balance measuring instrumenttechnical indicators
1. Speed measurement range: 400-30000 revolutions per minute
2. Vibration measurement range: 0-3000 μ m peak to peak value
3. One time removal of imbalance rate>80%
4. Phase tracking accuracy: less than ± 1 ° within 0-360 °
5. Display mode: Four line large character LCD displays multiple parameters of two measuring points simultaneously
VT700 on-site dynamic balance measuring instrumentFunction:
■ *'s application functions
It can perform single-sided and double-sided imbalance correction, and provide vibration analysis for single and dual channels, fast dynamic balance acquisition, vector decomposition and synthesis calculation, ISO allowable imbalance query, manual input simulation of dynamic balance, and other practical functions.
Excellent instrument performance
Microsoft Windows CE operating system, stable and efficient;
A high-performance embedded microprocessor with a frequency of 400MHz and data processing capability of *;
High density FPGA chips provide data acquisition and control;
Low noise circuit board manufacturing process and up to 1024 times hardware gain enable the resolution of vibration signals to reach 0.001um, with balance accuracy better than national standards;
Up to 1GB of data storage capacity, capable of storing 10000 sets of on-site balancing process records;
Adopting low-power hardware design, intelligent power management, and large capacity lithium battery pack, KMBALancer can work continuously for more than 7 hours after a single charge.
Main functions
The portable on-site dynamic balance measuring instrument has multifunctionality, which can be used as a tachometer and vibration measurement, especially with all the functions of dynamic balance measurement. (Real time display of unbalanced vibration quantity and phase)
● It has the ability to automatically measure the influence coefficient using the trial weight method and calculate single-sided and double-sided * counterweights, or directly calculate * counterweights based on the measured original vibration when the influence coefficient is known. It can calculate while measuring or input the calculation ability at once.
Has the ability to calculate the selected angle of the calculated weight to the left and right.
● Capable of frequency analysis for detecting vibration components at the same frequency, half frequency, and multiple frequency as the rotor.
● Easy to operate, the instrument automatically prompts, and can be used by general personnel
Precautions for operation:
1. Users should not easily press the "reset" button during continuous measurement, otherwise all data from the button will be lost. If you have an impact coefficient at hand, you can re-enter it.
2. It is necessary to carefully prepare the photoelectric signs and observe the accuracy of the machine speed. This is an important guarantee for the instrument to conduct dynamic balance testing.
There are multiple reasons that can cause significant machine vibration. Only when the amplitude of the same frequency accounts for a larger component of the total amplitude, can dynamic balancing be used to reduce vibration. On the contrary, it cannot achieve the desired effect.
In the dynamic balance weighing method, it is necessary to add the known weight to the known position of the measured surface, and pay attention to the changes in the amplitude and phase of the vibration after weighting and the original amplitude and phase of the vibration. If the data changes are not significant, the vibration reduction effect after calculation and processing will not be significant in the future. If the amplitude change is not significant, the weight of the test should be increased. If the phase change is not significant, the position of the trial weight should be moved again.
5. When balancing a rotor for the first time, the trial weight method must be used. After obtaining the influence coefficient through the trial weight method, the influence coefficient method can be used for balancing rotors of the same type, which is relatively simple to operate.
6. This instrument can be powered by AC 220V or by the built-in 12V battery. Generally, it is required to use AC 220V charging and 12V battery power supply, so that the internal noise of the machine is relatively low. Please note that when the battery voltage is below 10V, timely charging is required. Otherwise, it will affect the lifespan of the battery.
7. The magnetic suction seat equipped with the sensor has a high suction force and is easy to grip, please be very careful.