VOC concentration detector

NegotiableUpdate on 02/03
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
VOC detector
Product Details


Heating typeVOC concentration detector

The hydrogen flame ionization detector, which uses the entire measurement circuit heating type, is the latest VOC monitor. Due to the sample flow path being heated to high temperature for measurement (HOT FID), various T-VOCs can be quickly and continuously measured from low boiling point to high concentration, up to high boiling point. In addition, by using corrosion countermeasure type FID, it can also cope with the measurement of organic chlorine gases. In case of hydrogen flame extinguishing, the safety design automatically cuts off the hydrogen line, so you can use it with confidence.
The entire measuring flow path of this instrument is a heating type, equipped with a hydrogen flame ionization detector. Heat the sample airflow path to high temperature (HOT FID), from low concentrationLow boiling point to high concentrationHigh boiling point, capable of quickly and continuously measuring various T-VOCs. In addition, the use of anti-corrosion FID can also be applied to the determination of organochlorine gases. If the hydrogen flame stalls, the safety design of automatically cutting off the hydrogen flow path can be used with peace of mind.
Features:
1. High boiling point VOCs can also be stably and continuously measured, and data can be determined in a short period of time.
2. Equipped with anti-corrosion FID, it can continuously measure organic chlorine based gases.
3. Can be applied to emission management and control, explosion prevention, and other purposes.
Standard specifications:

Host modelEHF-770V

Measurement objectTotal hydrocarbons in exhaust gas (includingVOC

Determination methodHydrogen flame ionization detection method(FID

Heating type for the entire sample airflow path from the sample inlet: approximately130℃)

   Measurement range010020050010002000500010000ppmC (standard)
0~1, 2, 5 vol% C (high concentration)

   showvaluemistakepoorFS±2FS±1

   repetitivenessFS±1

   zeropointfloatmoveFS±2/dayFS±1/8h

   quantityChengfloatmoveFS±2/dayFS±1/8h
Sample taking amount: about 2L/min

oxygenqidrydisturbChange range below 10% (relative oxygen concentration change 0-21vol%)
response time90% response from instrument inlet within 10 seconds (when introducing calibration gas)

Fuel gasHigh purity hydrogen gas (using 99.99 UP gas cylinders or hydrogen generators)

Combustion supporting gas: Refined air (through built-in air purifier)

power supply AC100V±10V 50/60Hzshared
loseSend a signalDC01VTheDC010mV(Concentration output, all non insulated outputs)

Electricity consumption: Approximately500VA

appearancesizeW400 D400 H415mmExcluding handle

Quality : About28kg

   its HeAnti corrosion FID
Cut off the hydrogen flow path circuit when the engine is turned off

(Note: ※ is01000ppmCSpecifications within the scope.