According to the integration of information across the entire network, the core parameters of the Diane liquid chromatograph (equipped with UVD170U four channel UV/visible detector, P680A pump, TCC-100 chromatographic workstation) are as follows:
1、 Volume and weight specifications
UVD170U detector: The host size is about 48cm (length) x 21cm (width) x 43cm (height), and the weight is about 20kg; the matching P680A pump module size is about 40cm x 38cm x 19cm, and the weight is 12.3-16.8kg (slightly different due to configuration).
TCC-100 chromatography workstation: The size and weight data are not clearly disclosed and need to be confirmed in conjunction with the overall installation environment of the system.

2、 Instrument type
Category: High performance liquid chromatography (HPLC) system, integrating UV/visible detection, gradient elution pump, and chromatographic data processing functions, supporting quaternary low-pressure gradient elution and column temperature control.
3、 Application scenarios
Drug analysis: Separation, qualitative and quantitative analysis of UV absorbable organic drugs (such as antibiotics, vitamins);
Environmental monitoring: detection of organic pollutants and heavy metal ions in water (in conjunction with ion chromatography module);
Food testing: analysis of additives, pesticide residues, and nutritional components;
Research fields: Peak purity verification, multi-component mixture separation, metabolomics research, gas-liquid reactions (such as thiourea synthesis involving ammonia).
flow rate range
P680A pump: Equal mode 1-10000 μ L/min (1 μ L increment), high-pressure binary gradient mode 1-20000 μ L/min (equal mode).
pressure resistance
Pressure range: 0.1-50MPa (7250psi), suitable for chromatography columns with different packing materials such as C18, silica gel, zirconia columns, etc.
Flow accuracy
Flow rate accuracy: ± 0.1% (at 1mL/min), pressure pulse<1%, ensuring gradient elution stability.
Scope of injection
Automatic sampler: supports 1-250 μ L (standard needle), optional 2.5mL; injection volume increment of 0.1 μ L, reproducibility RSD<0.3% (5 μ L injection volume).
Sample injection number
Sample capacity: The automatic sampler sample rack can accommodate 192 1.2mL sample bottles, 117 1.8mL sample bottles, or 63 4.0mL sample bottles, supporting unmanned continuous sampling.
Data source: Based on information from relevant websites, if more detailed parameters are needed (such as specific interfaces and software functions of TCC-100 workstation), it is recommended to contact Dionex or authorized agents to obtain technical manuals.