Upgraded gas chromatograph

NegotiableUpdate on 02/19
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

GC9890B gas chromatograph is an upgraded version of type A; The host has 6 independent temperature controls, which can be connected to reverse control software. The digital signal is directly output, and there is no online value during peak hours.

Product Details

JunqiinstrumentEquipment (Shanghai) Co., Ltd

Sales phone number:/ fifty-seven million seven hundred and eighty-six thousand three hundred and eleven

Technical Department: 13761342293

* Main features
1
The friendly human-machine dialogue interface makes your operation simpler.
2The split/non split injection system makes analysis flexible and convenient.
3Equipped with a two-way valve control system, it facilitates online automatic sampling.
4
The high-precision EPC imported electronic proportional valve (flow) system makes your flow clear at a glance, with a control accuracy of 0.01 psi
Can more accurately set the gas flow rate.(Optional accessories)
5A comprehensive detection and fault diagnosis system can enable you to quickly identify and solve problems with the instrument.
6Wide temperature control range: ambient temperature+5 ℃~450 ℃, making the sample analysis range wider.
7Can be installed with the American HP-5890 gas chromatograph micro thermal conductivity detector to achieve complete docking.
8The unique gas cut-off protection system can minimize damage to the detector and chromatographic column.
9The column box can be equipped with an ultra-low temperature control system, with an ultra-low temperature control of -80 ℃, to meet your needs for low boiling point substance analysis.
10. The inter column compensation circuit electronically compensates for baseline drift during program temperature rise, reducing the complexity caused by the second column, detector, and auxiliary flow system. Two single column compensation channels can be installed simultaneously.

Column temperature box system
Temperature range: ambient temperature+5 ℃~450 ℃
Third order programmed heating, with a heating rate of 0-50 ℃/min; Incremental 0.1 ℃/min. Temperature control accuracy ± 0.015 ℃,
Users can recalibrate the furnace temperature and freely set the * temperature. The intelligent rear door opening system has stepless variable air flow in and out, which shortens the stable balance time of the system after heating/cooling. The time taken for the column box to drop from 350 ℃ to 50 ℃ is less than 6 minutes.

Sample injection system
1
Filling column sampler: suitable for various caliber filling columns and large-diameter capillary columns.
2. Capillary sampler: Optional split/non split injection system controlled by programming valve.
3
Optional options include our company's headspace sampler and thermal analyzer.

Detector system
1
Hydrogen flame ionization detector (FID):
Easy to disassemble and install, convenient for cleaning or replacing nozzles, simple to operate; The input signal can be logarithmic amplified, reducing interference, with high sensitivity, good linearity, and wide range.
Detection limit: Mt ≤ 5 ×
10-12g/s(N-Hexadecane)
Baseline noise: ≤ 6×
10-12A/H
Linear range: ≥105
Stable time:< 0.5h
2Thermal conductivity detector (TCD):
Sensitivity: ≥ 5000mv • ml/mg (n-hexadecane)
Microcell amplification ≥ 10000mv • ml/mg (n-hexadecane)
Baseline noise: ≤ 30 μ V (with a carrier gas of 99.999 helium)
Stable time: C-type<1.5h
3Flame photometric detector (FPD):
Detection limit: Phosphorus Mt ≤ 5 × 10 ^ 310-12g/s(Ethyl-1605)
Sulfur measurement Mt ≤ 1 ×10-11g/s(Thiophene)
4Electron Capture Detector (ECD):
Detection limit: Mt ≤ 1 ×10-13g/ml(r-666)
5Nitrogen phosphorus detector (NPD):
Detection limit: Phosphorus Mt ≤ 5 × 10 ^ 310-12g/s(Malathion)
Nitrogen measurement Mt ≤ 5 × 10 ^ 310-12g/s(Azobenzene)
Instrument appearance dimensions450mm*450mm*600mm
Weight: 46KG