The DNA6000 series universal source vector network analyzer provides various calibration methods such as frequency response, single port, response isolation, enhanced response, full dual port, and electrical calibration. It has multiple display formats such as logarithmic amplitude, linear amplitude, standing wave, phase, group delay, Smith chart, polar coordinates, etc. It is equipped with multiple standard interfaces such as USB, LAN, HDMI, etc., which can accurately measure the amplitude frequency characteristics, phase frequency characteristics, and group delay characteristics of microwave networks.
The DNA6000 series vector network analyzer retains the characteristics of excellent products, including performance indicators, instrument appearance, display effect, software interface, while controlling the volume, weight, and wind noise of the instrument to create a good user experience. This product can be widely used in fields such as electronics, communication, and microwave, and is a commonly used testing equipment in industrial and university research and mass production processes.
Universal Source Vector Network AnalyzerProduct Features:
• Frequency range: 5 kHz~26.5 GHz
• Number of ports: 2/4 ports
• Frequency resolution: 1 Hz
Maximum output power: 10 dBm
• High dynamic range: 127 dB (typ.)
Trace noise: 0.003 dB rms
• Intermediate frequency bandwidth range: 1 Hz to 10 MHz
• Compatible with mechanical and Ecal electronic calibration components, supporting multiple calibration types (SOLT, Response Short, Response Open, OSL, Enhanced Response 1 to 2, Response Thru)
Integrating S-parameters, impedance, standing wave, TDR time-domain analysis, fixture embedding/deintercalation, antenna testing, and other functions
• Volume (358.1 mm × 214.8 mm × 300 mm)
10.1-inch 1280 * 800 high-definition touch screen display
• Supports LAN, USB Device, USB Host, GPIB communication interfaces
• Supports standard SCPI commands
Supports multiple interfaces such as USB, LAN, HDMI, etc., facilitating system integration and data export.
• Support Web Control remote operation
• Supports dual operation modes of touch screen and physical buttons, and supports keyboard/mouse input
Product advantages:
Frequency range covers multiple applications
Provides a frequency range from 5 kHz to 26.5 GHz, supporting 4 or 2 test ports, accurately covering testing needs in areas such as basic passive components (such as filters, antennas, cables), material dielectric constants, and high-speed interconnects.

Wide dynamic range ensures performance characterization
The wide dynamic range exceeding 120 dB and extremely low trace noise ensure the accurate characterization of high suppression ratio devices and the stability of measurement results.

Rich analysis functions
Built in extreme line testing (Pass/Tail), standing wave ratio (SWR) measurement, Smith chart, time-domain reflectometer (TDR) and other application tools can efficiently complete both R&D validation and production line quality control.

Removal and embedding of fixtures
By easily removing and embedding the testing fixtures, adapters, and cables through fixture removal, the true S-parameters of the DUT itself can be accurately measured to ensure the reliability of the results.

Guided calibration
The built-in calibration wizard will guide you step by step to complete the operation clearly, whether you are a novice or an expert, you can quickly and accurately complete the settings, ensuring the accuracy of each measurement.

Optional mechanical or electronic calibration components
Provide high-precision, long-life mechanical calibration components covering different frequency bands and interface types to ensure traceability and high repeatability of test results. Electronic calibration components can significantly shorten the preparation time for testing and effectively avoid human errors, making them an ideal choice for pursuing efficiency and consistency.

Rich optional accessories
Through a comprehensive attachment ecosystem, you can have everything you need in one place, making reliable testing happen immediately.

Standard SCPI instructions, compatible with instruction set
Provide multiple remote control interfaces and support standard SCPI instructions, smoothly integrate or replace them into existing testing systems through instruction set compatibility, without the need to rewrite automation scripts, and retain familiar workflows.

Authorized agent of Puyuan: Suzhou Weiruike Electronics Co., Ltd
Our advantages:PuyuanShi De, Tech, Ri Zhi, Hai Si, Gu Wei, An Bai, AidexDingyangTonghui, Aino, etc
Ordering information:
DNA6082 frequency 5 kHz~8.5 GHz, 2 ports
DNA6084 frequency 5 kHz~8.5 GHz, 4-port
DNA6142 frequency 5 kHz~14 GHz, 2 ports
DNA6144 frequency 5 kHz~14 GHz, 4-port
DNA6202 frequency 5 kHz~20 GHz, 2 ports
DNA6204 frequency 5 kHz~20 GHz, 4-port
DNA6262 frequency 5 kHz~26.5 GHz, 2 ports
DNA6264 frequency 5 kHz~26.5 GHz, 4-port
Options:
DNA-TDA10 TDR Time Domain Reflectance Analysis
DNA-DTF10 DTF fault distance measurement
MCAL104-NM1 Mechanical Calibration Kit, DC~4.5 GHz, N-type (male) 50 Ω
MCAL104-NF1 Mechanical Calibration Kit, DC~4.5 GHz, N-type (female) 50 Ω
MCAL109-NM1 Mechanical Calibration Kit, DC~9 GHz, N-type (male) 50 Ω
MCAL109-NF1 Mechanical Calibration Kit, DC~9 GHz, N-type (female) 50 Ω
MCAL109-NK1 Mechanical Calibration Kit, DC~9 GHz, N-type (male and female) 50 Ω
MCAL104-SM1 Mechanical Calibration Kit, DC~4.5 GHz, SMA (Male)
MCAL104-SF1 Mechanical Calibration Kit, DC~4.5 GHz, SMA (Negative Head)
MCAL109-SM1 Mechanical Calibration Kit, DC~9 GHz, SMA (Male)
MCAL109-SF1 Mechanical Calibration Kit, DC~9 GHz, SMA (Negative Head)
MCAL109-SK1 Mechanical Calibration Kit, DC~9 GHz, SMA (Male and Female)
MCAL126-35K1 Mechanical Calibration Kit, DC~26.5 GHz, 3.5 mm (male and female)
MCAL226-35M5 4-in-1 OSLT Mechanical Calibration Kit, DC~26.5 GHz, 3.5 mm (male head)
MCAL226-35F5 4-in-1 OSLT Mechanical Calibration Kit, DC~26.5 GHz, 3.5 mm (female head)
ECAL109-NF2 electronic calibration component, 100 kHz~9 GHz, N-type (female) 50 Ω, 2-port
ECAL114-NF2 electronic calibration component, 100 kHz~14 GHz, N-type (female) 50 Ω, 2-port
ECAL126-35F2 electronic calibration component, 100 kHz~26.5 GHz, 3.5 mm (female head), 2 ports
CB-3.5M-3.5M-100-L-26G RF cable, DC~26.5 GHz, 3.5 mm (male) -3.5 mm (male), 100 cm
CB-SMAM-SMAM-100-L-18G RF cable, DC~18 GHz, SMA (male) - SMA (male), 100 cm
CB-NM-NM-100-L-18G RF cable, DC~18 GHz, N (male) - N (male), 100 cm
CB-NM-SMAM-100-L-18G RF cable, DC~18 GHz, N (male) - SMA (male), 100 cm
CB-NM-3.5M-100-L-18G RF cable, DC~18 GHz, N (male) -3.5mm (male), 100 cm
CB-NMD3.5F-3.5F-63-L-26G network distribution dedicated RF cable, DC~26.5 GHz, NMD 3.5mm (female head) -3.5mm (female head), 63.5 cm
AD-NF-NF-L-18G adapter, N (female head) - N (female head), DC ~ 18GHz
AD-NM-NM-L-18G adapter, N (male head) - N (male head), DC ~ 18GHz
AD-SMAF-SMAF-L-18G adapter, SMA (female head) - SMA (female head), DC ~ 18GHz
AD-SMAM-SMAM-L-18G adapter, SMA (male head) - SMA (male head), DC ~ 18GHz
AD-3.5F-3.5F-L-26G adapter, 3.5mm (female head) -3.5mm (female head), DC ~ 26.5GHz
AD-3.5M-3.5M-L-26G adapter, 3.5mm (male head) -3.5mm (male head), DC ~ 26.5GHz
AD-NM-BNCF-L-4G adapter, N (male) - BNC (female), DC ~ 4GHz
AD-SMAM-NM-L-18G adapter, SMA (male head) - N (male head), DC ~ 18GHz
AD-SMAF-NM-L-18G adapter, SMA (female head) - N (male head), DC ~ 18GHz
AD-SMAF-BNCM-L-4G adapter, SMA (female head) - BNC (male head), DC ~ 4GHz
AD-3.5M-2.92F-L-26G adapter, 3.5mm (male head) -2.92 (female head), DC ~ 26.5GHz
AD-3.5F-2.92M-L-26G adapter, 3.5mm (female head) -2.92 (male head), DC ~ 26.5GHz
TW8-8 torque wrench, 8 in lb, 8.1 mm open end
TW12-19 torque wrench, 12 in lb, 19.1 mm open end