Ultrasonic cooling and heating water meter

NegotiableUpdate on 11/19
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Introduction: Ultrasonic Cooling and Heating Water Meter Overview: Ultrasonic cooling and heating water meters are installed with a pair of temperature sensors on the upstream and downstream pipes passing through the heat transfer fluid. The flow meter is installed on the fluid inlet or reflux pipe (the installation position of the flow meter is different, and the final...)

Product Details

Overview of Ultrasonic Cold and Heat Water Meters:
Ultrasonic cold and heat water meters are installed with a pair of temperature sensors respectively on the upstream and downstream pipes passing through the heat transfer fluid, and the flow meter is installed on the fluid inlet or return pipe (where the flow meter is installed)
Different, the final measurement results are also different. The flow meter emits a pulse signal proportional to the flow rate, a pair of temperature sensors provide analog signals indicating the high or low temperature, and the integrator collects data from the flow rate and
The signal from the temperature sensor, which calculates the heat obtained by the heat exchange system using a calculation formula, is more complex compared to the household meters commonly used in the construction industry in the past, such as water meters, electricity meters, and gas meters
Design and higher technological content. Ultrasonic calorimeter is a product that includes mechanical, electronic, and informational components.
Technical characteristics of ultrasonic cold and heat water meters:
1. The transducer of brick technology and advanced electronic measurement technology ensure the accuracy and stability of flow measurement.
2. The measuring mechanism has no mechanical movement, and the measurement accuracy is not affected by the service life, resulting in low maintenance costs in the later stage.
3. Straight through body structure, stainless steel body. The inner wall of the body will not rust, ensuring the eternal stability of the flow field shape and minimal pressure loss.
4. Provide multiple communication methods including infrared, RS485, and M-BUS, enabling remote data transmission and centralized control.
5. Automatic error diagnosis with error message prompt function.
6. Easy to install, capable of water inlet and return installation.
7. Can produce high-temperature (up to 130 ℃) heat meters.
Technical parameters of ultrasonic cold and heat water meters:
Model number Nominal caliber
(mm)
ZUI high traffic
qs(m3/h)
Common traffic
qs(m3/h)
ZUI low traffic
qs(m3/h)
CTSBZ/R 50 30 15 0.3
65 50 25 0.5
80 80 40 0.8
100 120 60 1.2
accuracy class Level 2/Level 3
pressure loss <25kPa/qp
Nominal Pressure 1.6MPa
temperature sensor PT1000 platinum resistor direct insertion
Temperature calculation range 4-95℃
Temperature difference range 3-60℃
Temperature difference resolution 0.01
Environmental level Class A
Heat consumption calculation Starting from 0.25k
Protection level IP67 (calculator section)
power supply 3.6V lithium battery (>=3 years)
Ultrasonic cold and heat water meter data
nominal diameter
(mm)
Range ratio R Flow rate (m ³/h)
Starting flow ZUI low traffic Q1 Boundary flow Q2 Common traffic Q3 Overload flow Q4
DN10 200 0.002 0.0120 0.020 2.000 3.125
DN15 200 0.003 0.0125 0.020 2.500 3.125
DN20 200 0.0035 0.016 0.026 3.200 4.000
DN25 200 0.007 0.020 0.032 4.000 5.000
DN32 200 0.010 0.032 0.050 6.300 7.875
DN40 200 0.015 0.100 0.160 20.000 25.000
DN50 100 0.030 0.400 0.640 40.000 50.000
DN65 100 0.059 0.630 1.008 63.000 78.750
DN80 100 0.064 1.000 1.600 100.000 125.000
DN100 100 0.094 1.600 2.560 160.000 200.000
DN125 100 0.120 2.000 3.200 200.000 250.000
DN150 100 0.270 2.500 4.000 250.000 312.500
DN200 100 0.315 4.000 6.400 400.000 500.000
DN250 100 0.508 4.000 6.400 400.000 500.000
DN300 100 0.770 6.300 10.080 630.000 787.500


nominal diameter
(mm)
Range ratio R Flow rate (m ³/h)
Starting flow ZUI low traffic Q1 Boundary flow Q2 Common traffic Q3 Overload flow Q4
DN10 200 0.002 0.0120 0.020 2.000 3.125
DN15 200 0.003 0.0125 0.020 2.500 3.125
DN20 200 0.0035 0.016 0.026 3.200 4.000
DN25 200 0.007 0.020 0.032 4.000 5.000
DN32 200 0.010 0.032 0.050 6.300 7.875
DN40 200 0.015 0.100 0.160 20.000 25.000
DN50 100 0.030 0.400 0.640 40.000 50.000
DN65 100 0.059 0.630 1.008 63.000 78.750
DN80 100 0.064 1.000 1.600 100.000 125.000
DN100 100 0.094 1.600 2.560 160.000 200.000
DN125 100 0.120 2.000 3.200 200.000 250.000
DN150 100 0.270 2.500 4.000 250.000 312.500
DN200 100 0.315 4.000 6.400 400.000 500.000
DN250 100 0.508 4.000 6.400 400.000 500.000
DN300 100 0.770 6.300 10.080 630.000 787.500