Ultra high precision constant temperature water (oil) tank series

★ Can design and produce non-standard products completely according to user requirements

Temperature display resolution up to 0.0001 ℃
application area:
Biochemical field: rotary evaporator, Abbe refractometer, polarimeter, atomic absorption spectroscopy ICP-MS、ICP、 Nuclear magnetic resonance CCD、 Biological fermentation tanks, chemical reactors, etc
◆ Medical field: Superconducting magnetic resonance, linear accelerator CT、 Low magnetic field nuclear magnetic resonance, X-ray machine, microwave therapy machine, medical cold cap, cooling blanket, etc
◆ Physical and chemical fields: lasers, magnetic fields, various molecular pumps, diffusion pumps, ion pumps, and various water-cooled equipment used in the materials field
Materials field: electron microscopy, X-ray diffraction, X-ray fluorescence, vacuum sputtering electroplating, vacuum coating machine, ICP etching, various semiconductor equipment, fatigue testing machine, chemical deposition system, atomic deposition system, etc
Product Introduction:This series of ultra high precision constant temperature baths is developed to meet the extremely high requirements for constant temperature accuracy in various metrology, electronics, chemical, environmental protection, medicine, energy, refining, metallurgy, light industry, military and other departments and research institutes. After years of independent development, the integrated intelligent instrument temperature control is more accurate. In addition, the uniquely designed non heat centrifugal circulation pump makes the flow field and temperature field inside the bath turbulent and highly uniform. At present, the performance of the ultra-high precision constant temperature bath has reached the international leading level, and its biggest highlight is the digital display resolution of up to 0.0001 ℃. Our company has become the largest manufacturer of constant temperature baths in China. This device is widely used as a calibration standard in the manufacturing of various thermometers, various types of thermistors, and other temperature measuring instruments. It can also be designed as an automatic detection and sorting device. This product is also known as: high-precision standard constant temperature bath, high temperature standard calibration constant temperature oil bath, low temperature calibration standard constant temperature bath, thermometer calibration bath, measurement specific constant temperature bath
Main features:◎ Microcomputer intelligent control, integrated with the latest generation PID automatic temperature control program, large screen high brightness LCD screen, bilingual display in Chinese and English
◎ Built in AAA level high-precision PT100 temperature sensor
The inner liner and countertop are made of high-quality S304 brushed stainless steel panel
Dual use of water and oil, free choice of high and low temperatures (medium selected according to temperature range: pure water, methyl silicone oil, etc.)
◎ Humanized R-rounded design structure for front panel and countertop to avoid scratches
◎ External circulation function: The centrifugal jet circulation pump can draw out the constant temperature liquid in the tank, establish a second constant temperature field, and control the external experimental container of the machine
Internal circulation function: Adopting a non heat centrifugal circulation pump to avoid the influence of traditional water pumps on the tank temperature field due to their own heat generation. The internal circulation system is designed based on the principle of porous U-shaped reflux circulation, achieving turbulent and highly uniform flow and temperature fields inside the tank
The drainage system can meet the needs of various laboratories and enterprises for liquid exchange production
◎ Safety protection device:
1. Equipped with power-off protection function
2. Equipped with upper and lower temperature alarm setting function
3. Low water level protection and alarm function
4. Temperature runaway protection and alarm function
5. The heating tube has low water level anti dry burning and explosion-proof functions
◎ Digital display resolution: 0.0001 ℃
Temperature fluctuation value: ± 0.005~± 0.01 ℃
◎ Temperature uniformity: ± 0.005~± 0.01 ℃ horizontal/vertical
◎ The temperature range can be optionally extended to: -120~300 ℃
Technical parameters:
| Model number |
Temperature range (℃) |
Temperature uniformity (Horizontal/Vertical ℃) Pure water |
Inner groove size (mm) (Length X Width X Slot Depth) |
capacity (L) |
Circulation mode (Internal/External) |
Work slot opening (mm2) |
drainage |
| VKGH-5 |
Room temperature~100 |
±0.005~±0.01℃ |
275×190×120 |
5 |
Internal circulation |
180×140 |
have |
| VKGH -5A |
Room temperature~200 |
±0.005~±0.01℃ |
275×190×120 |
5 |
Internal circulation |
180×140 |
have |
| VKGH -5D |
Room temperature~300 |
±0.005~±0.01℃ |
275×190×120 |
5 |
Internal circulation |
180×140 |
/ |
| VKGH -10 |
Room temperature~100 |
±0.005~±0.01℃ |
275×195×180 |
10 |
Internal circulation |
180×140 |
have |
| VKGH -10A |
Room temperature~200 |
±0.005~±0.01℃ |
275×195×180 |
10 |
Internal circulation |
180×140 |
have |
| VKGH -10D |
Room temperature~300 |
±0.005~±0.01℃ |
275×195×180 |
10 |
Internal circulation |
180×140 |
/ |
| VKGH -15 |
Room temperature~100 |
±0.005~±0.01℃ |
300×250×200 |
15 |
Internal circulation |
235×160 |
have |
| VKGH -15A |
Room temperature~200 |
±0.005~±0.01℃ |
300×250×200 |
15 |
Internal circulation |
235×160 |
have |
| VKGH -15D |
Room temperature~300 |
±0.005~±0.01℃ |
300×250×200 |
15 |
Internal circulation |
235×160 |
/ |
| VKGH -20 |
Room temperature~100 |
±0.005~±0.01℃ |
300×250×270 |
20 |
Internal circulation |
235×160 |
have |
| VKGH -20A |
Room temperature~200 |
±0.005~±0.01℃ |
300×250×270 |
20 |
Internal circulation |
235×160 |
Yes, there is |
| VKGH -20D |
Room temperature~300 |
±0.005~±0.01℃ |
300×250×270 |
20 |
Internal circulation |
235×160 |
/ |
| VKGH -25 |
Room temperature~100 |
±0.005~±0.01℃ |
300×250×335 |
25 |
Internal circulation |
235×160 |
have |
| VKGH -25A |
Room temperature~200 |
±0.005~±0.01℃ |
300×250×335 |
25 |
Internal circulation |
235×160 |
have |
| VKGH -25D |
Room temperature~300 |
±0.005~±0.01℃ |
300×250×335 |
25 |
Internal circulation |
235×160 |
/ |
| VKGH -30 |
Room temperature~100 |
±0.005~±0.01℃ |
440×325×210 |
30 |
External circulation |
310×280 |
have |
| VKGH -30A |
Room temperature~200 |
±0.005~±0.01℃ |
440×325×210 |
30 |
Internal circulation |
310×280 |
have |
| VKGH -30D |
Room temperature~300 |
±0.005~±0.01℃ |
440×325×210 |
30 |
Internal circulation |
310×280 |
/ |
| VKGH -40 |
Room temperature~100 |
±0.005~±0.01℃ |
500×340×240 |
40 |
External circulation |
350×300 |
have |
| VKGH -40A |
Room temperature~200 |
±0.005~±0.01℃ |
500×340×240 |
40 |
Internal circulation |
350×300 |
have |
| VKGH -40D |
Room temperature~300 |
±0.005~±0.01℃ |
500×340×240 |
40 |
Internal circulation |
350×300 |
/ |
| VKGH -50 |
Room temperature~100 |
±0.005~±0.01℃ |
500×340×300 |
50 |
External circulation |
350×300 |
have |
| VKGH -50A |
Room temperature~200 |
±0.005~±0.01℃ |
500×340×300 |
50 |
Internal circulation |
350×300 |
have |
| VKGH -50D |
Room temperature~300 |
±0.005~±0.01℃ |
500×340×300 |
50 |
Internal circulation |
350×300 |
/ |
| VKGH -100 |
Room temperature~100 |
±0.005~±0.01℃ |
625×400×400 |
100 |
External circulation |
480×380 |
have |
| VKGH -100A |
Room temperature~200 |
±0.005~±0.01℃ |
625×400×400 |
100 |
Internal circulation |
480×380 |
have |
| VKGH -100D |
Room temperature~300 |
±0.005~±0.01℃ |
625×400×400 |
100 |
Internal circulation |
480×380 |
/ |
Optional Function Guide:1. Optional extended external PT100 temperature sensor, which can detect and control the temperature of the external system in real time during external circulation
2. Optional built-in temperature control program with 1-30 segments, capable of automatic program temperature control and real-time display of set temperature time program operation status
3. Optional RS232 or RS485 communication interface, easy to connect to the upper computer, with Modbus RTU communication protocol
4. Optional design and installation of magnetic stirring system, which can directly stir the liquid sample in the beaker placed in the constant temperature bath working room with magnetic stirring, without the need for an external vertical mixer, reducing redundant operations
5. Optional cooling coils built into the tank can quickly cool and control the exothermic reaction of the system
6. Optional height adjustable immersion platform for easy adjustment of the liquid level of the immersed sample