UK Aquaread portable multi parameter water quality detectorAP-7000
AP-7000 is a probe produced by Aquaread for long-term water quality monitoring, which includes anti biological pollution components and a self-cleaning system.

UK Aquaread portable multi parameter water quality detectorProduct Features:
1. It can be monitored on-site for a long time without the need for regular cleaning and maintenance.
2. The standard configuration is optical dissolved oxygen pH、ORP、EC、 Depth and temperature basic parameter measurement, with six interfaces available for connecting any six ISE and optical sensors.
3. Data can be read on-site through Aquaread GPS Aquameter, saved through Aquaread Logger, and remotely transmitted through Aquaread Telemetric System
There are two types of probes to choose from, one is AP-7000 and the other is AP-7000-SDI. The AP-7000-SDI system provides SDI and Modbus (RS-485) outputs for easy system integration.
5. The anti fouling components and casing, as well as the double-sided brush automatic cleaning, ensure that the instrument can be used in outdoor environments for a long time without the need for regular cleaning and maintenance.
6. Modular design: The probe and data module can be freely combined, and the electrodes inside the probe can be freely combined.
7. Anti biological pollution components: Nano material coating, anti biological pollution.
8. GPS Geographic Location Information: Collecting data to protect geographic location information without the need for manual recording.
9. Optional RS485 and SDI outputs: convenient for system integration.
10. Optional remote transmission: Remote transmission via GPRS or other means.

Aquaread portable multi parameter water quality analysis comes standard with sensors:
| AP-7000-LTD water quality probe | |||
| Protection level | IP68 (submerged for 10 meters) | ||
| immersion depth | Small 150mm (6 '), large 100m (330') | ||
| operating temperature | -5 ° C to+50 ° C (23 ° F-122 ° F) | ||
| Size (length x outer diameter) | 450mm x 77mm (18' x 3') 1350g (3 lbs) |
||
| Weight (including cables) | |||
| parameter | scope | resolution | accuracy |
| 光学溶解氧 | 0-500%/0-50.00mg/L | 0.1%/0.01mg/L | 0-200%: ± 1% reading, 200% -500%: ± 10% reading |
| conductivity | 0–200mS/cm (200,000μS/cm) | Three automatically determined ranges: 0-9999 μ S/cm, 10.00-99.99mS/cm, 100.0-200.0mS/cm | +1% reading or+0.1 units, whichever is greater |
| Total dissolved solids* | 0 – 100,000 mg/L (ppm) | Two automatically determined ranges: 0-9999mg/L, 10.00-1000g/L | +1% reading or+0.1 units, whichever is greater |
| Resistivity* | 5Ω·cm – 1MΩ·cm | Two automatically determined ranges: 5-9999 Ω· cm, 10.0-1000.0K Ω· cm | +1% reading or+0.1 units, whichever is greater |
| Salinity* | 0-70 PSU / 0-70 ppt (g/Kg) | 0.01 PSU / 0.01 ppt | +1% reading or+0.1 units, whichever is greater |
| Specific gravity of seawater* | 0 – 50 σ t | 0.1 σ t | ± 1.0 σ t |
| PH value | 0 – 14 pH / ± 625mV | 0.01 pH / ± 0.1mV | ± 0.01 pH / ± 5mV |
| Oxidation-reduction potential | ± 2000mV | 0.1mV | ± 5mV |
| depth | 0 – 100m (0 – 330F) | 0.01m/F | +/- 1% |
| \\Temperature | -5 ° C to+50 ° C (23 ° F to 122 ° F) | 0.1°C/F | ± 0.5°C |
The reading marked with * is calculated based on conductivity and temperature
Optional ISE and optical sensors:
ISE electrode: ammonium/ammonia, chlorine, fluoride, nitrate, calcium
Optical electrodes: turbidity, chlorophyll, freshwater blue-green algae, marine blue-green algae, rhodamine WT dye, fluorescent dye, finished oil.
Optional ISE electrode
| parameter | scope | resolution | accuracy |
| Ammonia nitrogen † | 0 – 1,000mg/L (ppm) | Two automatically determined ranges: 0.00-99.9mg/L, 100.0-99.9mg/L ± 10% |
± 10% |
| nitrate | 0 – 1,000mg/L (ppm) | ± 10% | |
| chloride | 0 – 1,000mg/L (ppm) | ± 10% | |
| fluoride | 0 – 1,000mg/L (ppm) | ± 10% | |
| calcium | 0 – 1,000mg/L (ppm) | ± 10% | |
| ammonium | 0 – 1,000mg/L (ppm) | ± 10% |
The parameter with this symbol requires an ammonium electrode. The reading is calculated based on the readings from the ammonium electrode, pH electrode, and temperature electrode
Optional optical electrode
| Chlorophyll A | 0 – 500 μg/L (ppb) | 0.1 μg/L | ± 2% |
| Shallow water blue-green algae | 0 – 300,000 cells/mL | 1 cell/mL | ± 2% |
| Marine blue-green algae | 0 – 200,000 cells/mL | 1 cell/mL | ± 2% |
| turbidity | 0 – 3000 NTU |
Two automatically determined ranges: 0.0 99.9 NTU, 100-3000 NTU | ± 2% |
| Ruodanming | 0 – 500 μg/L (ppb) |
0.1 μg/L | ± 5% |
| fluorescent dye | 0 – 500 μg/L (ppb) |
0.1 μg/L | ± 5% |
| refined oil | 0 – 10,000 μg/L (ppb) |
0.1 μg/L | ± 2% |