- Phone
-
Address
Building 6, Optics Valley Electromechanical Industrial Park, No. 84 Gaoxin 5th Road, Donghu New Technology Development Zone, Wuhan City, Hubei Province
Wuhan Ultra High Voltage Power Technology Co., Ltd
Building 6, Optics Valley Electromechanical Industrial Park, No. 84 Gaoxin 5th Road, Donghu New Technology Development Zone, Wuhan City, Hubei Province
Gas chromatography analysis technology is a separation and analysis technique for multi-component mixtures. It mainly utilizes the differences in boiling point, polarity, and adsorption coefficient of each component in the sample in the chromatographic column to separate each component in the column, and performs qualitative and quantitative analysis on the separated components.
Gas chromatography uses gas as the mobile phase (carrier gas). When the sample is sent into the injection port and vaporized, it is carried by the carrier gas into the packed column or capillary column. Due to the differences in boiling point, polarity, and adsorption coefficient of each component in the sample, the components are separated in the column. Then, the detector connected to the column detects each component in order based on its physical and chemical properties. Finally, the data is transmitted to the chromatography workstation through a serial port or network, and the gas chromatogram of each component is recorded and analyzed by the chromatography workstation to obtain the analysis report of each component.
Due to its high separation efficiency, fast analysis speed, and low sample usage, this analysis method has been widely used in various sectors such as petrochemicals, biochemistry, medicine and health, health quarantine, food inspection, environmental protection, food industry, and medical clinical practice. Gas chromatography has solved problems such as quality inspection, scientific research, pollution detection, and production control of intermediates and industrial products in these fields.
Product nickname: Oil chromatography analyzer, fully automatic oil chromatography analyzer, automatic oil chromatography analyzer, chromatograph
Product parameters
UHV-645 portable oil chromatographtechnical parameters
| Network anti control system | The internal CAN method adopts an interface board design, which can be freely converted into network port output |
| Number of signal output bits | 24 digits |
| communication interface | Network interface output (Category 6 Ethernet cable connection) |
| circuit design | Adopting ARM embedded design, it is easy to achieve wireless control, remote control, and mobile APP control |
| Temperature Control System | Six independent temperature control channels |
| temperature control | Room temperature above -450 ℃, using liquid nitrogen refrigeration: -80 ℃ -450 ℃ |
| Column box temperature control accuracy | ±0.02℃ |
| temperature-programmed | 36 levels, 0.1 degrees per level |
| display module | Large screen LCD display |
| display precision | 0.01℃ |
| Column box lift rate | 0-80 ℃/min (adjustable increment of 0.1 ℃/min) can reach 120 ℃/min |
| Program heating repeatability | ≤1% |
| TCD detector sensitivity | S value ≥ 10000mv. ml/mg (benzene), up to 12000; Mv. ml/mg (benzene) |
| Baseline noise | ≤8uv |
| baseline drift | ≤20uv/30min |
| FID detector detection limit | ≤3×10-12G/s (Hexadecane) |
| Baseline noise | ≤ 2×10-13A |
| baseline drift | ≤ 5×10-13A |
| Detection limit of ECD detector | ≤3 x 10-14g/s(r-666) |
| Baseline noise | ≤ 1×10-13A |
| baseline drift | ≤ 5×10-13A |
| FPD detector detection limit | ≤2 x 10-11? G/s (medium sulfur) |
| Baseline noise | ≤ 2×10-13A |
| baseline drift | ≤ 4×10-13A |
| extension | Can add 6 external events |
| Automation Engineering | Additional features can be added: automatic ignition function, automatic sampler connection, four-way flow pressure display function, and the option to use a reverse control workstation for reverse control |
Note:
1. The appearance of the product is subject to the actual product. Technical parameters and models are subject to change without prior notice. If there is any act of theft or copying, legal responsibility will be pursued.
2. For more information on ultra-high voltage products, please enter the product center.
Product features
1. The 10/100M adaptive Ethernet communication interface with technology and built-in IP protocol stack enable the instrument to easily realize long-distance data transmission through the enterprise's internal LAN and Internet; Facilitating the setup of the laboratory, simplifying the configuration of the laboratory, and facilitating the management of analytical data.
2UHV-645 portable oil chromatographThree independent connection processes are designed internally, which can be connected to local processing (laboratory site), unit supervisors (such as quality inspection department heads, production plant managers, etc.), and higher-level supervisors (such as technical personnel, etc.), making it convenient for unit supervisors and higher-level supervisors to monitor the operation of instruments and analyze data results in real time.
3. The network version workstation equipped with the instrument can support multiple chromatographs (253 units) simultaneously, enabling data processing and control, simplifying document management, and reducing users' laboratory investment and operating costs.
4. The instrument can be connected to the manufacturer through the Internet to realize remote diagnosis, remote program update, etc. (with the user's permission).
5. The instrument can be equipped with a 5.7-inch color LCD screen or color touch screen to meet different user needs.
6. The system has two operating systems in Chinese and English, which can be freely switched.
7. The temperature control area, electronic flow controller (EFC), and electronic pressure controller (EPC) can be freely named by users for convenient use (optional).
8. The instrument adopts a multi processor parallel working mode, making it more stable and reliable; It can meet the analysis of complex samples and can be equipped with multiple high-performance detectors such as FID, TCD, ECD, FPD, and NPD. Up to four detectors can be installed simultaneously. Additional detectors can also be used, making it easy to purchase and install other detectors after purchasing the instrument.
9. The instrument adopts a modular structural design, which is clear in design, easy to replace and upgrade, and protects the effectiveness of investment.
10. A brand new microcomputer temperature control system with high temperature control accuracy, reliability, and anti-interference performance; Equipped with a six channel independent temperature control system, it can achieve sixteen step programmed temperature rise, enabling the device to handle a wider range of sample analysis; Equipped with a column box automatic rear door opening system, the precision of low-temperature control is improved, and the speed of temperature rise/fall is faster.
11. The optional electronic flow controller (EFC) and electronic pressure controller (EPC) of the instrument achieve digital control, which can greatly improve the reproducibility of qualitative and quantitative results.
12. The instrument is designed with a timed self starting program, which can easily complete online analysis of gas samples (requiring online automatic injection components).
13. The operating system of the fully microcomputer controlled keyboard is simple and convenient to operate; And design detector automatic recognition technology; It has the functions of fault diagnosis and power-off data protection, and can automatically memorize set parameters.
14. The chromatography machine is equipped with a low-noise, high-resolution 24 bit AD circuit and has the functions of baseline storage and baseline subtraction.
15. Collecting chromatographic signals and data processing, suitable for operating systems such as WinXP, Win2000, Windows 7, etc. The sampling data can be read in from CDF files that comply with A/A (American Society for Analysis) standards, which can be integrated with chromatographic workstations such as Agilent and Waters.
16. The chromatography system with independent intellectual property rights has a standard interface of MODBUS/TCP, which can be easily integrated with DCS.
17. The instrument can be integrated with automatic samplers produced by multiple manufacturers both domestically and internationally; Such as Shimadzu's AOC-20i and Italy's HTA company's HT series high-efficiency gas-phase liquid automatic sampler.






Product Video Product Atlas
Product Attachment Diagram
main unit of the instrument
Multi functional degassing oscillator
hydrogen generator
air generator
gas cylinder
Single stage pressure reducing valve
wrench
attachment
nut
Fill the column stone ink pad
hat pressing
O-ring, stainless steel gas pipeline
fuse
screwdriver
USB drive
Gas path O-ring, small and large head injection pad
Soap foam flowmeter
Glass sampler
ground wire
power cord
Product detail images
complete set
main unit of the instrument
Side of the host
Back of the host
display screen
Column front pressure position
Top of the instrument
Top Display
TCL and back pressure regulation
Air conditioning knob
network interface
pressure gauge
Back pressure, reference interface
Gas intake port
Multi functional degassing oscillator
Multi functional degassing oscillator display screen
hydrogen generator
Back of hydrogen generator
Output pressure and flow display area
air generator
Back of air generator
Air inlet and outlet
Gas tank drain valve
Output pressure gauge