Overview:
|
The U G N series viscous hanging wall quartz glass tube level gauge can directly measure the liquid level of various media in containers, especially suitable for
Measure the liquid level of media that are viscous, opaque, colored, dirty, prone to crystallization, prone to wall sticking, and require frequent flushing. Such as paraffin
Heavy oil, tar, asphalt, syrup and other strongly viscous colored liquids. This series of instruments has a wide visible surface, clear display, and sealing performance
It has the advantages of good performance, long service life, easy installation and maintenance, and can easily achieve online flushing. It is widely used in the petroleum and chemical industries
Multiple industrial sectors including electricity, metallurgy, natural gas, military, and food.
Structural principle:
|
The U G N series viscous hanging wall quartz glass tube level gauge is an addition to the U G K J wide liquid chamber jacket level gauge
Made with an online flushing device. The flange of the liquid level gauge is connected to the flange on the container to form a connector. Using the principle of the connector
Quartz tubes can directly observe the liquid level of various media in containers. In the gas phase, natural light directly passes through the quartz tube and is emitted from the viewing window,
In the liquid phase, natural light is directly transmitted through a quartz tube and absorbed onto an opaque colored medium, presenting the natural color of the medium
The interface between gas and liquid becomes clear and distinguishable.
| Main technical parameters: |
Center distance: Ordinary type ≤ 2500 m (can be specially made according to user needs)
◆ Ultra long type: ≤ 12000 mm
Adjustable range of center distance: ≤± 15m
◆ Nominal pressure: ≤ P N6.3M P a
Working temperature: ≤ 450 ℃
◆ Visual length: Normal type=Center distance -250 mm (can be specially made according to user needs)
No blind spot type=center distance
◆ Automatic closing pressure: ≥ 0.3 M P a
◆ Flushing and sewage interface: N P T 1/2 "internal thread (can be specially made according to user needs)
◆ Electric light source voltage: A C 36 V or A C 220 V
◆ Electric heating voltage: A C 220 V
◆ Heat tracing steam pressure: ≤ 1.0 M P a
◆ Heat tracing jacket joint: G 1/2 "external thread (can also be made according to user requirements)
◆ Liquid receiving material: carbon steel, stainless steel (can be specially made according to user needs)
◆ Process connection: Flange connection: H G/T 20592-2009 D N 20 (can be specially made according to user needs)
Threaded connection: G3/4 "external thread (can be specially made according to user needs)