- Phone
-
Address
6th Floor, Building 9, No. 115, Lane 1276, Nanle Road, Songjiang District, Shanghai
Shanghai Yuanxi Instrument Co., Ltd
6th Floor, Building 9, No. 115, Lane 1276, Nanle Road, Songjiang District, Shanghai
TOC-5000RNType Total Organic Carbon AnalyzerFeatures and functions
*The operating software adopts database assisted data management to achieve one-stop operation of instrument control, status monitoring, data processing, and data access
The independently developed high-performance NDIR detector adopts imported light sources and detectors, with high detection sensitivity and good stability
The liquid circuit design is matched with a reasonable process control system to ensure that the amount of sample entering the combustion tube during switching and cleaning is minimized as much as possible, fully extending the service life of the catalyst and combustion tube
The newly designed high-performance cracking furnace adopts 24V weak voltage power supply, ensuring the safety of users' use, and has significantly improved performance in heating, cooling, and temperature control stability
Carefully designed test report templates, flexible selection of multiple or single sample test reports to meet users' different application needs
Multiple standard curves can be selected for analysis during sample testing, and the software automatically selects excellent standard curves based on the sample response values and brings them into the calculation
Optional solid testing module to meet the needs of solid testing and achieve diversity in the types of test samples
Optional enhanced halogen removal tube can be selected to reduce the impact of halogen substances on the detector, enhance the sensitivity and stability of detection
Optional 20 bit automatic sampler for automated user experience
Optional audit trail version software, compliant with GMP requirements for computerized system validation and FDA 21 CFR PART 11 requirements for electronic data integrity, electronic signatures, and audit trail
TOC-5000RNType Total Organic Carbon Analyzerindicator
model |
TOC-5000 RN (dry process) |
detector |
NDIR (Non Dispersive Infrared Detection) |
Measurement project |
TC、IC、TOC(TC-IC)、NPOC |
Measurement range |
0-1000mg/L |
detection limit |
TC:50μg/L IC:20μg/L |
Oxidation principle |
High temperature catalytic oxidation |
Operation method |
computer control |
Applicable samples |
Liquid, solid (optional) |
Gas requirements |
Oxygen: ≥ 99.995% |
Power supply |
AC110V ± 10% or AC220V ± 10%, 50/60Hz, 700W |
size |
631*450*478mm |